Installation
Item no. 10405047-02, Revision 04
31 ( 48 )
8.4.3
Setting values
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
Ü
Keep to the following values:
Taper cleaning
4,5 - 6 bar
Pneumatic system for tool change
5 - 8 bar
8.5
Sensor electronics of measuring system (optional accessory)
The sensor cable is not highly flexible; i.e. it is not suitable for constant move-
ments.
Ü
Fit the electronics in line with this.
Ü
Secure the housings with two screws.
Ä
See illustration for the drill hole pattern.
8.5.1
Wiring of measuring system
The sensor is pre-assembled in the unclamp unit and connected to the sensor
electronics.
Ü
Do not shorten the sensor cable, since the measuring system was cali-
brated with this cable length.
Ü
Do not kink the cable.
There is a connector at the output of the sensor electronics unit. The connec-
tion cable (not included in delivery) must have the following characteristics:
q
Outside diameter max. 5 mm.
q
4 x 0.14 mm²
q
Shielded
q
Highly flexible: suitable for cable carriers.
q
Max. length for corresponding interference elimination: 50 m