background image

Technical Specifications

Item no. 10004021, Revision 02

16 ( 36 )

Note: Damage due to incorrect performance data.

The values of the parameters relate exclusively to the motor.

u

HF spindle values: See tables S1-100%, S6-60% and S2-Pmax.

Parameter

*

Meaning

Value

Unit

p0304

Rated voltage (phase-phase)

167,4

Vrms

p0305

Rated current

11,7

Arms

p0307

Rated power

2,252

kW

p0308

Rated power factor

0,79

cos φ

p0310

Rated frequency

833

Hz

p0311

Rated speed

48.522

rpm

---

Rated power loss

383

W

---

Rated rotation speed

45.000

rpm

p0312

Rated torque

0,441

Nm

p0314

Motor poles (pairs)

1

---

p0320

Rated magnetization current

6,46

Arms

p0322

Maximum speed

60.000

rpm

p0326

Stalling torque correction factor

100

%

p0335

Cooling type

Liquid cooled

p0341

Moment of inertia

0,0000991

kgm²

p0348

Field weakening operating speed VDC=600V

71.820

rpm

p0350

Stator resistance, cold (strand)

0,427

p0353

Series inductance (strand)

0

mH

p0354

Rotor resistance, cold

0,241

p0356

Stator stray inductance

0,098

mH

p0358

Rotor stray inductance

0,141

mH

p0360

Main inductance

2,601

mH

p0604

Motor temperature warning threshold

110

°C

p0605

Motor temperature fault threshold

130

°C

p0640

Current limit

16

Arms

p1800

Pulse frequency

16

kHz

---

DC link voltage

VDC

---

Series capacitance

µF

---

Maximum voltage

V

---

Idle reduction

%

---

Stator stray reactance X1

0,514

---

Rotor stray reactance X2

0,739

---

Main field reactance Xh

13,618

(*) Parameters for Siemens SINAMICS 120

Содержание Z62-M445.01 S5

Страница 1: ...Manual Z62 M445 01 S5 High Frequency Spindle Manual tool change...

Страница 2: ...opment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanish...

Страница 3: ...sensor digital differential magneto resistor 19 6 6 Air borne noise emissions 19 7 Operating location 20 8 Installation 21 8 1 Installing the HF spindle 21 8 2 Diameter of media supply line 22 8 3 Co...

Страница 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Страница 5: ...w wrench q Hook wrench q Transport packaging Check the high frequency spindle for completeness upon delivery 2 1 1 Optional accessories Available on request q Spindle holder q Frequency converter q Ch...

Страница 6: ...in accordance with the Machinery Directive and cannot perform any function independently The HF spindle can only be operated in conjunction with a machine tool and a frequency con verter 3 1 Permissib...

Страница 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Страница 8: ...h great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure functionality u Never operat...

Страница 9: ...and maintenance work only after shutting down the HF spindle and after the shaft has come to a standstill Install all safety and protective devices of the machine immediately after completing work 4 4...

Страница 10: ...Technical description Item no 10004021 Revision 02 10 36 5 Technical description 5 1 Connections of HF spindle 2 1 3 2 1 Electrical connection 2 Cooling water G 1 8 3 Sealing air G 1 8...

Страница 11: ...the machine con troller Note Connect the SpeedTEC quick locking connector u For the combination SpeedTEC connector plug SpeedTEC cable plug u Remove the O ring on the SpeedTEC connector plug 5 3 Cooli...

Страница 12: ...cy 750 Hz Motor poles pairs 1 Rated rotation speed 45 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor T...

Страница 13: ...Technical Specifications Item no 10004021 Revision 02 13 36 6 1 Dimensions Clamping range...

Страница 14: ...d values S1 100 Rated rotation speed 5 000 10 000 20 000 30 000 40 000 45 000 rpm Speed 2 875 8 823 18 500 28 507 38 515 43 519 rpm Frequency 83 167 333 500 667 750 Hz Rated power 0 134 0 43 0 91 1 36...

Страница 15: ...842 kW Torque 0 483 0 681 0 647 0 64 0 63 0 63 Nm Voltage 24 44 73 104 136 151 V Current 12 15 9 15 8 15 8 15 8 15 8 A cos 0 93 0 92 0 88 0 86 0 85 0 84 Note on operation with static frequency conver...

Страница 16: ...46 Arms p0322 Maximum speed 60 000 rpm p0326 Stalling torque correction factor 100 p0335 Cooling type Liquid cooled p0341 Moment of inertia 0 0000991 kgm p0348 Field weakening operating speed VDC 600...

Страница 17: ...Stator Stator U DFP Digitale Feldplatte Differential magneto resistor 0 75 mm 0 14 mm 0 14 mm U V W PIN 3 7 4 pole 4 7 2 pole 2 7 2 pole 2 4 2 pole 3 7 2 pole AC 7 01 2 PTC PTC AC 8 01 4 C B A G blau...

Страница 18: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Страница 19: ...resistor Rx is already integrated in the evaluation unit FC u Only connect signal and ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000...

Страница 20: ...speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface...

Страница 21: ...e fittings Make sure that the connections are flexible and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal all connections for cooling water...

Страница 22: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Страница 23: ...n air quality see Air purity classes ISO 8573 1 23 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Страница 24: ...al forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Turn the shaft of the spindle at least ten times by hand Bef...

Страница 25: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Страница 26: ...ystem is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged 10 1 Clockwise Sample illustration Direction of rotatio...

Страница 27: ...n the inner taper of the shaft Lightly grease the thread of the clamping nut Push the collet into the taper of the mount Insert the tool Make sure that the shank of the clamped tool does not press on...

Страница 28: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Страница 29: ...to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount...

Страница 30: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Страница 31: ...ewater Dispose of cooling media in accordance with local regulations If the HF spindle cannot be dismantled send the HF spindle to Nakanishi Jaeger GmbH Nakanishi Jaeger GmbH shall not assume the cost...

Страница 32: ...er See also Spindle becomes hot 32 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q C...

Страница 33: ...or is dis torted q Only use spindle holders from the original accessories or holders produced according to the tolerances specified by Nakanishi Jaeger GmbH HF spindle clamped too tightly q Only tigh...

Страница 34: ...serve all points in the Tool change 26 and Mainte nance 29 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Страница 35: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stand...

Страница 36: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z62 M445 01 S5 Item no 10004021 Revision 02 Date 01 09 2023 Language EN Jaeger Spindles North Ame...

Отзывы: