Technical description
Item no. 10404085, Revision 02
13 ( 44 )
5.4
Sealing air
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The sealing air prevents foreign bodies such as chips and liquids (e.g. emul-
sions) from entering the HF spindle.
Ü
Check that air escapes at the front between the housing and the rotating
parts of the HF spindle.
5.5
Taper cleaning
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
Taper cleaning prevents chips and liquids from entering the shaft during a
tool change and causing contamination and damage to the inner taper and
the clamping system.
5.6
Pneumatic tool change
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The tool change or tool taper change is performed pneumatically.
During this, a mechanism is operated inside the HF spindle which clamps, re-
leases, or ejects the tool taper or collet.
5.7
Cylinder vent
The cylinder takes in air when clamping the taper/tool. This air must be clean
and dry.
Only if necessary:
Ü
Remove the sound absorber.
Ü
Fit the relevant hose fitting in place of the sound absorber.
Ü
Fit the relevant hose to the hose fitting.
Ü
Select the length of the hose so that its free end protrudes out of the hose
fitting far enough that no dirt or moisture can be taken into the hose.