![Jäger KA1-03/50 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/jager-0/ka1-03-50/ka1-03-50_manual_3272942036.webp)
Service and repairs
Item no. 10301048, Revision 12
36 ( 40 )
14.2
Malfunctions
The list below can be used to quickly investigate and eliminate faults.
HF spindle not rotating
Cause
Troubleshooting
No
power supply
q
Check the frequency converter.
q
Check the machine.
q
Check all electrical connections.
q
Check all wires in the motor cable.
q
Activate the Start/Reset button.
Thermal protection has
been activated
q
Wait until the HF spindle has cooled down.
q
Check the frequency converter for error messages. If no
messages are illuminated, start the frequency converter.
(See also “Spindle becomes hot
Frequency converter
has
shut down
q
Check the error messages in the frequency converter man-
ual.
Tool change
initiated
q
Turn off the pneumatic system for the tool change.
HF spindle becomes hot
Cause
Troubleshooting
Insufficient cooling
q
Check the power of the chiller.
q
Check the water level of the chiller.
q
Check the connections and the cooling hoses.
q
Check the cooling circuit.
q
Check the chiller for error messages.
Phase missing
q
Check all wires in the motor cable for cable breaks.
Machining too heavy
q
Check the rotational direction of the HF spindle.
q
Check the rotational direction of the tool.
q
Check the tool for damage.
q
Reduce the machining load intensity.
Frequency converter
incorrectly set
q
Compare the values for the HF spindle with the set values
on the frequency converter.
Содержание KA1-03/50
Страница 1: ...Manual KA1 03 50 High Frequency Spindle Pneumatic direct change...
Страница 4: ...Contents Item no 10301048 Revision 12 4 40...
Страница 15: ...Technical Specifications Item no 10301048 Revision 12 15 40 6 1 Dimensions Clamping range...
Страница 17: ...Technical Specifications Item no 10301048 Revision 12 17 40 6 2 1 Performance Diagram...