Service and repairs
Item no. 10204237, Revision 00
33 ( 36 )
14.2
Malfunctions
The list below can be used to quickly investigate and eliminate faults.
HF spindle not rotating
Cause
Troubleshooting
No
power supply
q
Check the frequency converter.
q
Check the machine.
q
Check all electrical connections.
q
Check all wires in the motor cable.
q
Activate the Start/Reset button.
Thermal protection has
been activated
q
Wait until the HF spindle has cooled down.
q
Check the frequency converter for error messages. If no
messages are illuminated, start the frequency converter.
(See also “Spindle becomes hot
Frequency converter
has
shut down
q
Check the error messages in the frequency converter man-
ual.
HF spindle becomes hot
Cause
Troubleshooting
Insufficient cooling
q
Check the power of the chiller.
q
Check the water level of the chiller.
q
Check the connections and the cooling hoses.
q
Check the cooling circuit.
q
Check the chiller for error messages.
Phase missing
q
Check all wires in the motor cable for cable breaks.
Machining too heavy
q
Check the rotational direction of the HF spindle.
q
Check the rotational direction of the tool.
q
Check the tool for damage.
q
Reduce the machining load intensity.
Frequency converter
incorrectly set
q
Compare the values for the HF spindle with the set values
on the frequency converter.
HF spindle becomes loud
Cause
Troubleshooting
Tool unsuitable
q
Only use balanced tools.
(Also see the "Tools for high speed cutting
" section.)
q
Check the tool for damage.
q
Replace damaged tool.
HF spindle is not
clamped truly or is dis-
torted
q
Only use spindle holders from the original accessories or
holders produced according to the tolerances specified by
Nakanishi Jaeger GmbH
.
Bearings damaged
q
Contact
Nakanishi Jaeger GmbH
service.
Sensor does not send any
signals
Cause
Troubleshooting
No connection to sen-
sor
q
Check the lines and connections.