4

 

 

. Applications of general functions 

 

3-1 Specification of weighing function 

1.

 

Press down button 

  to start the scale; this time the whole screen will be displayed 

and then count down, when screen shows      0.00 X    , the scale may be used to weigh; 

if backlight is needed, please press down button 

. (It is not need to press down 

the button if Auto backlight is set). 

2. Press down button 

  to deduct the weight of article; press down button 

 to 

cancel the deduction. 

(Note: if the deducted weight is within the zeroing range, the deduction may be 

cancelled and the scale is zeroed) 

3. Press down button 

  to shift the weighing units. 

Caution: the symbol of weighing unit will flash when the weight becomes unstable 

during the weighing. 

 

3-2 Specification of counting function 

1. Under the weighing mode, press down button 

 to show  XXXX pcs  on screen 

and to enter the counting function. 

2. Then press down button 

to enter the sampling mode for counting, and    SE 0pcs 

will be displayed on screen this time; please press down button 

  to select one out 

of the following five sampling quantities in a cyclic manner: 20, 50, 100, 200, and 500. 

3.   After selecting the sampling quantity, place the article whose quantity is the same with                 

the selected one on the scale pan, and press down button 

 to begin sampling; 

when the sound “bi” is heard and “SE” is disappeared, the sampling process is 

completed.  

 

Содержание SNUGIII Series

Страница 1: ...2 Specificatin of counting function 3 3 Specification of percentage function 3 4 Setting of time and date 4 4 5 5 Setting of various parameters 4 1 Entry and parameter adjustment mode 4 2 Specificati...

Страница 2: ...ects enter the scale Be sure to select the suitable transformer whose output is DC 9V 400ma please use a separate power socket and the transformer delivered by the scale manufacturer in order to avoid...

Страница 3: ...sted of 5 components and they must be assembled together before being used 2 First assemble four sides of windshield A B by inserting A into B from top to bottom or from bottom to up 3 Place the assem...

Страница 4: ...on specification of buttons and display window Button for Start Stop Button for zeroing It returns the weight to zero may return the value displayed on screen to zero position zeroing range is 2 of th...

Страница 5: ...Press down button to shift the weighing units Caution the symbol of weighing unit will flash when the weight becomes unstable during the weighing 3 2 Specification of counting function 1 Under the wei...

Страница 6: ...ntity place the article whose quantity is the same with the selected one on the scale pan and press down button to begin sampling when the sound bi is heard and SE is disappeared the sampling process...

Страница 7: ...then press down button to select Internal option Procedure 3 After completing the modification of internal options press down button to exit in case the next option should be set press down button to...

Страница 8: ...ed may be cancelled temporarily Press down button to select ON OFF and complete the setting Ozt TROY OUNCE ON in use or OFF not in use Dwt PENNY WEIGHT ON in use or OFF not in use MM JPN ON in use or...

Страница 9: ...ime AU 60 Auto Stop 60 min later 2400 4800 Setting of RS 232 transmission function Note Selection of transmission speed 9600 d 0 No limitation of zero display d 1 In case the indication is below zero...

Страница 10: ...ff Auto backlight off No backlight Backlight mode of display window Note there are three backlight modes that may increase effectively the convenience of application on Backlight keeps ON Pr co Signal...

Страница 11: ...rocedure 1 Under Stop mode first hold down button then press down button once to energize the scale and then release button Count Procedure 2 Press down button to enter calibration mode CAL Procedure...

Страница 12: ...cale and then release all pressed buttons L CAL Procedure 2 After clearing away the scale pan press down button to enter zero calibration On0 Procedure 3 After the sound bi is heard place the weight e...

Страница 13: ...right of SNUG III pin 2 is for signal output and pin 5 is for grounding and other pins are in reserve BAUD RATE 2400 OR 4800 OR 9600 bps DATA BIT 8 PARITY BIT N NONE STOP BIT 1 CODE ASCII BIT FORMAT L...

Страница 14: ...ial transmission speed should be set correspondingly USB peripheral devices should be used as follows 1 Connect this electronic scale to a computer with USB line and then start the electronic scale in...

Страница 15: ...t Err5 The weight of an article exceeds the maximal capacity 9e Remove the over heavy article from the pan promptly and avoid the similar error from then to avoid the possible damage Err6 The weight f...

Страница 16: ...we beg your pardon for this 1 You fail to show the warranty of products or the writing of the warranty is too illegible to be discerned 2 The damage of scale is due to the abnormal or incorrect appli...

Отзывы: