JADEVER SCALE 

SNUG III                                                                                                                               

13

 

 

 

6-2 Printing format of various peripheral devices 

PC SH-24 

ZEBRA 

BP443 

2007-07-10 10:26:22 

T.W.: +   0.00g    

N.W.: +   0.06g    

G.W.: +   0.06g   

2007-07-10  

10:30:23 

T.W.: +   0.00g   

N.W.: -   0.25g   

G.W.: -   0.25g 

2007-07-10   

10:26:22 

T.W.: +   0.00g    

N.W.: +   0.06g    

G.W.: +   0.06g 

2007-07-10   

10:26:22 

T.W.: +   0.00g    

N.W.: +   0.06g    

G.W.: +   0.06g 

2007-07-10 10:26:59 

Total:+            3PCS 

2007-07-10  

10:31:18 

Total:+     

10PCS 

2007-07-10    

10:26:59 

 

    Total:+        3PCS

2007-07-10    

10:26:59 

 

    Total:+        3PCS 

2007-07-10 10:28:02 

Total:+            7% 

2007-07-10  

10:32:09 

Total:+            9% 

2007-07-10    

10:26:59 

 

Total:+    3% 

2007-07-10    

10:26:59 

 

Total:+    3% 

 
6-3 Specification of USB interface application 
For applying USB devices, the cautions below must be followed: 

1. This USB interface may be connected only with computers. 

2. The computer must be installed first with the necessary driving program that may be 

downloaded from the website of our company. 

3. After the driving program for computer is installed, the communication between this 

device and the computer acts as serial communication. The serial transmission speed 

should be set correspondingly. 

USB peripheral devices should be used as follows:   

1. Connect this electronic scale to a computer with USB line and then start the electronic 

scale; in case the computer has not been installed with the needed driving program, the 

computer will show the related information to prompt that a new hardware is found and 

needs the driving program. 

2. After the installation of driving program, perform a test with hyper-terminal of computer to 

determine whether data is transmitted. The procedure for opening hyper-terminal of 

computer is as follows: Start — all programs — attachments — communication — 

hyper-terminal; input the name press down button “Confirm” to confirm the inputted name, 

select COM3 or COM4, and then press down button “Confirm” once again; select the 

corresponding serial transmission speed (select 9600 if the scale is set as 9600), confirm 

it, and then communication can be started.   

3. USB communication is like RS-232 communication; if users have their own receiving 

terminals of computer, they may use their own terminals for the communication. 

Users may select one out of USB interface and RS-232 interface based on their 

requirement. 

 

Содержание SNUGIII Series

Страница 1: ...2 Specificatin of counting function 3 3 Specification of percentage function 3 4 Setting of time and date 4 4 5 5 Setting of various parameters 4 1 Entry and parameter adjustment mode 4 2 Specificati...

Страница 2: ...ects enter the scale Be sure to select the suitable transformer whose output is DC 9V 400ma please use a separate power socket and the transformer delivered by the scale manufacturer in order to avoid...

Страница 3: ...sted of 5 components and they must be assembled together before being used 2 First assemble four sides of windshield A B by inserting A into B from top to bottom or from bottom to up 3 Place the assem...

Страница 4: ...on specification of buttons and display window Button for Start Stop Button for zeroing It returns the weight to zero may return the value displayed on screen to zero position zeroing range is 2 of th...

Страница 5: ...Press down button to shift the weighing units Caution the symbol of weighing unit will flash when the weight becomes unstable during the weighing 3 2 Specification of counting function 1 Under the wei...

Страница 6: ...ntity place the article whose quantity is the same with the selected one on the scale pan and press down button to begin sampling when the sound bi is heard and SE is disappeared the sampling process...

Страница 7: ...then press down button to select Internal option Procedure 3 After completing the modification of internal options press down button to exit in case the next option should be set press down button to...

Страница 8: ...ed may be cancelled temporarily Press down button to select ON OFF and complete the setting Ozt TROY OUNCE ON in use or OFF not in use Dwt PENNY WEIGHT ON in use or OFF not in use MM JPN ON in use or...

Страница 9: ...ime AU 60 Auto Stop 60 min later 2400 4800 Setting of RS 232 transmission function Note Selection of transmission speed 9600 d 0 No limitation of zero display d 1 In case the indication is below zero...

Страница 10: ...ff Auto backlight off No backlight Backlight mode of display window Note there are three backlight modes that may increase effectively the convenience of application on Backlight keeps ON Pr co Signal...

Страница 11: ...rocedure 1 Under Stop mode first hold down button then press down button once to energize the scale and then release button Count Procedure 2 Press down button to enter calibration mode CAL Procedure...

Страница 12: ...cale and then release all pressed buttons L CAL Procedure 2 After clearing away the scale pan press down button to enter zero calibration On0 Procedure 3 After the sound bi is heard place the weight e...

Страница 13: ...right of SNUG III pin 2 is for signal output and pin 5 is for grounding and other pins are in reserve BAUD RATE 2400 OR 4800 OR 9600 bps DATA BIT 8 PARITY BIT N NONE STOP BIT 1 CODE ASCII BIT FORMAT L...

Страница 14: ...ial transmission speed should be set correspondingly USB peripheral devices should be used as follows 1 Connect this electronic scale to a computer with USB line and then start the electronic scale in...

Страница 15: ...t Err5 The weight of an article exceeds the maximal capacity 9e Remove the over heavy article from the pan promptly and avoid the similar error from then to avoid the possible damage Err6 The weight f...

Страница 16: ...we beg your pardon for this 1 You fail to show the warranty of products or the writing of the warranty is too illegible to be discerned 2 The damage of scale is due to the abnormal or incorrect appli...

Отзывы: