JWI-501
4
3-9-1-2
When choose
on
and press <
TARE
>, now enter to set limit. “
under
” lamp is
lighting , max figure is blinking. Press<
SET/0~9
> once to add 1. Press <
TARE
> to
confirm. When finishing, auto exit and set “
over
”(same as set under limit). After finish, turn
back to normal weighing mode.
3-9-1-3
When low limit > high limit, it displays off, then exit.
3-9-1-4
Alarming indicate: m is the weight
When m
≥
high limit,
“over”
lamp is lighting and flickering.
When low limit <m<high limit,
“accept”
lamp is lighting (not flickering).
When m
≤
low limit,
“under”
lamp is lighting.
Note
:
If the stable indication does not appear, no lamp lights.
3-9-2
UnItS
: choose unit.
Default = kg
3-9-2-1
When it displays units, press <
TARE
> to enter. Press <
SET/0~9
> to change.
Press <
TARE
> to confirm. Units
:
h9(kg), pcs, (counting), lb.lb(decimal pounds)
3-9-2-2
Counting
:
When it displays “pcs”, press<
TARE
>. Now “
pcs
” lamp lighting.
Press and hold <
ON/ZERO
>,
it
displays count and return to 0. Then put
the sample (as
much as possible, but don’t more than max.capacity). After stable, press<
TARE
>.
Press
<
SET/0~9
>
to add 1 and press<
TARE
>to choose. After finishing, it displays pcs and
“
pcs
” lamp lighting.
exit counting: choose a weighing unit.
Note: Quantities of max less 30000
3-9-3
A-OFF
: choose auto power off.
Default = n
When it displays
A-OFF
, press <
TARE
> to enter. Press <
SET/0~9
> to choose “
n”
or “
y”
,
n
= not in auto power off situation
;
y
= after 10 minutes in zeroing, auto-off.
3-9-4
FILt
: set display mode.
Default = 3
When it displays
FILt
, press <
TARE
>to enter. Press <
SET/0~9
> to choose
filt-1
or
filt-2
or
filt-3
or
filt-4
. Press <
TARE
>to confirm.
filt-1
:
When add weight to scale, it will show the value till stable.
filt-2
:
When add weight to scale, it will show slow.
filt-3
:
When add weight to scale, it will show fast. (Recommend)
filt-4
:
When add weight to scale, it will show much faster.