JWI-501
2
2-2 Character Prompt
dc x.xx
:
Mean the voltage of battery is x.xxv .
-----
:
Show this as the weight over 100%fs+9e, with the ding sounding, this means over
load, reduce the weight.
-batlo-
:
The voltage is lower. You can use it for a short while and recharge immediately.
c_end
:
Recharge is end.
err-0
:
Overload zero of loadcell. Re-adjust or change loadcell.
3 Operation guide
3-1 Install and adjust
Insert the pole into platform base and indicator, and tighten up screws. Adjust feet to let
the platform in level.
3-2 Turn on and turn off
Turn on
:
Press <
ON/ZERO
> key. It displays software version. After that, it will show
dc-x.xx
(voltage of battery). Self-inspection starts. After countdown, the
“zero”
lamp will
light. Now the scale is in a working state.
Turn off
:
Press <
OFF
> key.
Auto turn off
:
When scale is in auto off state. It will be auto off after 10 minutes of no
operation.
(
see 3-9-3
)
Low voltage off: When the voltage is lower than 5.6v, it will auto turn off.
3-3 Zero
When without taring, the weight display is
≤4% max. capa.
. Press <
ON/ZERO
>, then it
will shows “
0
”
,
and “
zero
” lamp is lighting.
3-4 Weighing
Put weight to pan, it shows the weight.
Содержание JWI-501 Series
Страница 8: ...JWI 501 7 ...