background image

  

JADAK   flexpoint™   HS-­‐‑1M   User’s   Manual

   

   

    Page   21   

Beeper Tone - Good Read

 

 

Scan  one  of  the  following  codes  to  set  the  tone  or  pitch  of  the  Good  Read  beep.  

Default  =  Medium.    

    

  

          

  

      

 

  

Low

 

*  Medium

 

High  

  

 
 

Beeper Time - Good Read

 

 

Scan  one  of  the  following  codes  to  set  the  duration  of  the  Good  Read  beep.  
Default  =  Medium.    

    

  

  

                       

  

  

Short

 

*  Medium

   

 

 

   

Long  

  

Содержание flexpoint HS-1M

Страница 1: ... Series N User s Manual ...

Страница 2: ...11 Chapter 2 Interface Settings Connecting the HS 1M with an RS 232 Port 12 RS 232 Default Settings 13 RS 232 Baud Rate 13 RS 232 Word Length 14 Connecting the HS 1M with USB Port 15 USB Interface Options 16 USB HID Keyboard Emulation 16 USB COM Port Emulation 16 Keyboard Country Layout 17 Keyboard Control Character Output 18 Numeric Keypad Mode 18 Default Options 19 Custom Default Settings 19 Fac...

Страница 3: ...e Good Read 21 No Reads 22 No Read Message 22 Miscellaneous Indicators 23 Beeper Beep on BEL 23 Beeper Power Up Beep 23 Error LED Duration 23 Aimer Mode 24 Aimer Delay 24 Vibration 25 Vibration Modes 25 Vibration Pulse Count 25 Vibration Time 26 Trigger Commands 27 Trigger Modes 27 Manual Trigger level 27 Presentation Mode 27 Trigger Time Out 28 Multiple Symbols Mode 28 Good Read Delay 29 Re read ...

Страница 4: ...how Device Serial Number 31 Chapter 5 Data Editing Data Editing Overview 32 Transmit AIM ID Character 32 Prefixes 33 Prefix Block String 33 Prefix Clear 33 Suffixes 34 Suffix Block String 34 Suffix Clear 34 Chapter 6 Imaging Illumination Brightness 35 Snap an Image 36 Send an Image to Host 36 Image Width and Height 36 Decode Window 37 Decode Window Top Bottom 37 Decode Window Left Right 38 Decode ...

Страница 5: ...de 11 Defaults 41 Code 11 On Off 41 Code 11 Minimum and Maximum Length 41 Code 11 Check Digit 42 Code 128 43 Code 128 Defaults 43 Code 128 On Off 43 Code 128 Minimum and Maximum Length 43 ISBT 128 On Off 43 Code 39 44 Code 39 Defaults 44 Code 39 On Off 44 Code 39 Minimum and Maximum Length 44 Code 39 Full ASCII Conversion 44 Code 39 Check Digit 45 Code 39 Convert to Code 32 Pharmacode 45 Trioptic ...

Страница 6: ...JAN 8 On Off 48 EAN 13 JAN 13 48 EAN 13 JAN 13 Defaults 48 EAN 13 JAN 13 On Off 48 GS1 128 Formerly UCC EAN128 49 GS1 DataBar Formerly RSS 14 50 GS 1 DataBar Defaults 50 GS 1 DataBar On Off 50 GS1 DataBar Limited Formerly RSS Limited 50 GS 1 DataBar Limited Defaults 50 GS 1 DataBar Limited On Off 50 GS1 DataBar Expanded Formerly RSS Expanded 51 GS 1 DataBar Expanded Defaults 51 GS 1 DataBar Expand...

Страница 7: ...5 Check Digit 53 Matrix 2 of 5 54 Matrix 2 of 5 Defaults 54 Matrix 2 of 5 On Off 54 Matrix 2 of 5 Minimum and Maximum Length 54 MSI 55 MSI Defaults 55 MSI On Off 55 MSI Minimum and Maximum Length 55 MSI Check Digits 56 UPC A 57 UPC A Defaults 57 UPC A On Off 57 UPC A Check Digit 57 UPC E1 57 UPC E 0 58 UPC E 0 Defaults 58 UPC E On Off 58 UPC E 0 Check Digit 58 UPC E 0 Expanded Mode On Off 58 ...

Страница 8: ...mum and Maximum Length 60 2D Matrix Symbologies 61 Aztec Code 61 Aztec Code Defaults 61 Aztec Code On Off 61 Aztec Code Minimum and Maximum Length 61 Data Matrix 62 Data Matrix Defaults 62 Data Matrix On Off 62 Data Matrix Minimum and Maximum Length 62 Maxi Code 63 Maxi Code Defaults 63 Maxi Code On Off 63 Maxi Code Minimum and Maximum Length 63 QR Code 64 QR Code Defaults 64 QR Code On Off 64 QR ...

Страница 9: ...pport Obtaining Technical Assistance or Factory Service 69 Limited Warranty 70 Statement of Agency Compliance 71 FCC Class B Compliance Statement 71 flexpoint HS 1 Series N Declaration of Conformity 72 Operating Characteristics 73 Safety and Regulatory Notices 74 Appendices Appendix A Command Format 75 Appendix A1 2 Command List and Standard Default Parameters 78 Appendix B Programming Chart 82 Ap...

Страница 10: ...tion is also included JADAK s bar code scanners are factory programmed for the most common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide or by sending the commands below them Note An asterisk next to an option indicates the default setting CAT HS 1M Class 2 Laser Warning Some versions of the HS 1M conta...

Страница 11: ...on string is an 11 digit string with the last 5 digits being a factory configuration number Please consult JADAK for configuration information Note Instead of a configuration string this line can also contain a customer specific JDK product number in the format JDK xxxx Revision This shows the revision of the configuration Serial Number The serial number format is as follows YYMMDD NNN Where YY Ye...

Страница 12: ...ger when it is farther from the code Symbologies with smaller bars or elements lower mil size should be read closer to the unit Symbologies with larger bars or elements higher mil size as well as 1D barcodes with a lot of data in general should be read farther from the unit To read single or multiple symbols on a page or on an object hold the HS 1M at an appropriate distance from the target pull t...

Страница 13: ...ower supply connector to the serial interface cable Plug in the power supply to the cable s pigtail and a power outlet in the wall Alternatively power can be supplied via one of the pins of the HS 1M s DB9 connector when the interface cable doesn t feature a pigtail 3 Once the HS 1M has been fully connected power up the computer 4 If connecting the HS 1M using an RS 232 interface all communication...

Страница 14: ...g the correct Baud Rate the data from the HS 1M will be sent to the terminal at the specified rate The baud rate for RS 232 interface can be set by sending the serial command 232BAUD x where x is one of the allowed values of 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 or by building scanning a menu command barcode Several commonly used RS 232 Baud Rate menu command barcodes are includ...

Страница 15: ...acter If an application requires only ASCII Hex characters 0 through 7F decimal i e text digits and punctuation select 7 data bits For applications that need the full ASCII set supported select 8 data bits per character Default 8 Stop Bits sets the number of stop bits at 1 or 2 Default 1 7 Data 1 Stop Parity None 7 Data 2 Stop Parity None 8 Data 1 Stop Parity None 7 Data 1 Stop Parity Even 7 Data ...

Страница 16: ...ter The driver is available from your JADAK technical support contact No driver is required when using the USB HID Keyboard interface 2 Turn off power to the terminal computer 3 Connect the appropriate interface cable to the HS 1M hand scanner Note For the HS 1M to work properly you must have the correct cable for your type of terminal computer 4 Plug the USB A connector into a free USB port on yo...

Страница 17: ...ogram the HS1 M for USB HID Keyboard mode Note The HS 1M must be power cycled after programming this interface USB HID Keyboard USB COM Port Emulation Scan the following code to program the HS1 M to emulate a regular RS 232 based COM port Note The HS 1M must be power cycled after programming this interface USB COM Emulation ...

Страница 18: ...ulation use the following KBD_CTY commands or programming barcodes to set the specific Keyboard layout for your language Default United States Note These commands are not applicable for RS 232 HS 1M s United States United Kingdom Belgium Denmark Finland Sweden France Germany Italy Netherlands Norway Portugal Spain ...

Страница 19: ...g out an actual Carriage Return hex 0D it will send CR as readable ASCII text Default Disabled Note These commands are not applicable for RS 232 HS 1M s Enable Disable Numeric Keypad Mode Use these commands to send the data as if it were entered on a numerical keypad This of course only applies to numbers 0 to 9 Default Disabled Note These commands are not applicable for RS 232 HS 1M s Enable Disa...

Страница 20: ...e unit to its custom default settings Note The HS 1M must be power cycled after programming this command Note To re set custom defaults please contact JADAK Factory Default Settings Scan the following code revert the unit to its factory default settings Note The HS 1M must be power cycled after programming this command ...

Страница 21: ...ood Read The beeper may be programmed On or Off in response to a good read Turning this option off only turns off the beeper s response to a good read indication All error and menu beeps are still audible Default Enabled Enable Disable Beeper Volume Good Read The beeper volume codes modify the volume of the beep the HS 1M emits on a good read When set to off error and menu beeps are still audible ...

Страница 22: ...Tone Good Read Scan one of the following codes to set the tone or pitch of the Good Read beep Default Medium Low Medium High Beeper Time Good Read Scan one of the following codes to set the duration of the Good Read beep Default Medium Short Medium Long ...

Страница 23: ... codes to enable or disable the NR message Default Disable No Read Enable No Read Disable No Read No Read Message The Aforementioned No Read signer NR can be changed if you require a custom message By using the command NORDMSG with ASCII text up to a 100 characters you can customize this message Several typical No Read Message menu command barcodes are included below Default NR No Read Message Set...

Страница 24: ...he HS 1M is equipped with a red LED that usually functions as an indication for errors These commands set the Error LED Duration Time in steps of 1 millisecond from 1ms up to 1 second Default 100 milliseconds If a different duration other than those provided is needed it can be set either by sending the serial command ELEDDUR x where x is a value between 0 Off and 1000 or by scanning the top barco...

Страница 25: ...e scanner s illumination won t show until the delay time has passed This command sets the Aimer Delay Time in steps of 1 millisecond from 1ms up to 4000ms 4 seconds Default Off Several commonly used Aimer Delay menu command barcodes are included below If a different delay time other than those provided is needed it can be set either by sending the serial command AIM_DLY x where x is a value betwee...

Страница 26: ...s are sleeping Vibration Modes The HS 1M can use its vibration engine to vibrate in different situations Use one of the codes below to set the vibration mode of the HS 1M Default Disabled Don t vibrate Vibrate on good read Vibrate on No Read Vibrate on BEL from host Vibrate on error Vibration Pulse Count Set the Vibration Pulse count i e number of vibrations between 1 and 5 pulses Each pulse s dur...

Страница 27: ...nu command barcodes are included below Sample settings Vibration time 100ms Vibration time 200ms Vibration time 300ms Vibration time 500ms If a different vibration time other than those provided is needed it can be set either by sending the serial command VIBTIME x where x is a value between 0 and 1000 or by scanning the barcode below and then set the time by scanning the digit codes and the SAVE ...

Страница 28: ...turns the trigger ON TRGOFF This command turns the trigger OFF Trigger Modes Manual Trigger level You can activate the HS 1M by pressing the trigger or sending the serial trigger command TRGON When in manual trigger mode the HS 1M scans until a bar code is read until the trigger is released or the trigger time out occurs Use the command below to enable Manual Trigger Mode Manual level Trigger Pres...

Страница 29: ...nsecutively to set a custom Trigger Time Note TRGTIME 0 sets an infinite Trigger Time Out Sample settings Infinite Trigger Time Out Trigger Time Out 1 0 seconds Trigger Time Out 5 0 seconds Trigger Time Out 9 9 seconds Multiple Symbols Mode This sets the option to allow you to read multiple symbols with a single pull of the trigger If you press and hold the trigger aiming at a series of symbols it...

Страница 30: ...mples No Good Read delay Good Read delay 0 2 seconds Good Read delay 0 5 seconds Good Read delay 1 0 seconds Good Read delay 2 0 seconds Good Read delay 5 0 seconds If a different delay time other than those provided is needed it can either be set by sending the serial command DLYGDRD x where x is a value between 0 and 30000 to set the time between 0 no delay and 30000 30 sec in steps of 1millisec...

Страница 31: ... time 600 milliseconds Note Re read Delay only works when the HS 1M is in Presentation Mode Setting examples No Re read delay Re read delay 0 1 seconds Re read delay 0 6 seconds Re read delay 1 0 seconds Re read delay 2 0 seconds Re read delay 5 0 seconds If a different delay time other than those provided is needed it can either be set by sending the serial command DLYRERD x where x is a value be...

Страница 32: ... the HS 1M hand scanner Report the list of available Programming Commands All of the supported serial commands of the HS 1M along with a short description and the current setting value will be serially output when this barcode is scanned Report Detailed Scan Engine Info Revision Show Software Revision Show Revision Time Show Device Serial Number ...

Страница 33: ...sage string The selections in this section are used to build the user defined data into the message string The following illustration shows the breakdown of a message string Transmit AIM ID Character Use the following codes to transmit an AIM ID or Symbol ID Character before a possible prefix Default Don t Transmit AIM ID See Appendix C for a chart of all supported barcodes and their corresponding...

Страница 34: ...ic ASCII character as Prefix or by scanning the barcode below and then set the ASCII character by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Look at the ASCII conversion chart to see what hex digits convert to specific ASCII characters For instance if all the scanned barcodes need to have an A added to them in front of the data string e...

Страница 35: ...o hexadecimal digits to define a specific ASCII character or set of characters as Suffix or by scanning the barcode below and then set the ASCII character by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Look at the ASCII conversion chart in Appendix D to see what hex digits convert to specific ASCII characters You can also program more th...

Страница 36: ... you need to take an image This chapter describes some of the functions that are related to image capturing Illumination Brightness Use the command LEDSPWR to set the Illumination LEDs Power between Off and 100 with a value between 0 Off and 3 100 Note that this setting also is in place when scanning barcodes All illumination brightness menu command barcodes are included below Default 3 High Illum...

Страница 37: ...age to Host Use the command IMGGETX to get or send an image from the device to the host You can add arguments to this command for specific usage xm sets the send protocol to X Modem jpg sends the image as jpeg format default bmp q xx sets the quality of the image where xx is a value between 1 and 100 highest quality Example IMGGETX xm jpg q 30 sends the image as a jpg file via X Modem with a quali...

Страница 38: ...able Decode Windowing Disable Decode Windowing To define the Decode Window one needs to set the boundaries for Top Bottom Left and Right These boundaries are defined by pixel values within the full frame e g 844 x 640 pixels Note There are automated restrictions to prohibit a negative Decode Window size This means that the Bottom value cannot be above Top and likewise for the values for Left and R...

Страница 39: ...el value by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Default Left boundary WINDECL 338 Default Right boundary WINDECR 506 Decode Window Left Decode Window Right Decode Window Defaults Set all Decode Window settings to their default configuration and values This is a screenshot of an example where a Decode Window with T 260 B 390 L 40 ...

Страница 40: ...128 UPC E GS 1 Databar RSS 14 UPC E1 Note Please contact JADAK if you re looking to scan a symbology that s not listed here All Symbologies If you want to decode all the symbologies allowable for your HS 1M scan the All Symbologies On code Enable All If on the other hand you want to decode only a particular symbology scan All Symbologies Off Disable All followed by the On symbol for that particula...

Страница 41: ...combination with numerical values to set the minimum and maximum length for allowed Codabar barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 2 and 55 or by scanning one of the barcodes below and then set the length by scanning the digit co...

Страница 42: ...nation with numerical values to set the minimum and maximum length for allowed Code 11 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 55 or by scanning one of the barcodes below and then set the length by scanning the digit codes a...

Страница 43: ...y look for a check digit to decide if the code is valid Code 11 usually has 1 check digit and some codes have 2 check digits Either option can be chosen to be just validated or validated and transmitted Default 1 Check Digit Validate 1 Check Digit Validate 2 Check Digits Validate ...

Страница 44: ...5 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 55 or by scanning one of the barcodes below and then set the length by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Code 128 Minimum length Code 128 Maximum length ISBT 128 On Off IS...

Страница 45: ...t maximum length 48 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 48 or by scanning one of the barcodes below and then set the length by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Code 39 Minimum length Code 39 Maximum length Co...

Страница 46: ...rmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Default Disabled Note In order for this parameter to work Code 39 must be enabled Enable Disable Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code...

Страница 47: ...on with numerical values to set the minimum and maximum length for allowed Code 93 barcodes Default minimum length 0 Default maximum length 55 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 55 or by scanning one of the barcodes below and then set the length by scanning the digit codes and t...

Страница 48: ... Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length for allowed Composite Code barcodes Default minimum length 1 Default maximum length 2435 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 2435 or by scanning one of the barcod...

Страница 49: ...with this code EAN 8 JAN 8 On Off Scan one of the codes below to enable or disable EAN 8 Default Enabled Enable Disable EAN 13 JAN 13 EAN 13 JAN 13 Defaults Set the EAN 13 settings to their default configuration with this code EAN 13 JAN 13 On Off Scan one of the codes below to enable or disable EAN 13 Default Enabled Enable Disable ...

Страница 50: ... JADAK flexpoint HS 1M User s Manual Page 49 GS1 128 Formerly UCC EAN128 Scan one of the codes below to enable or disable GS1 128 Decoding Default Enabled Enable Disable ...

Страница 51: ...taBar On Off Scan one of the codes below to enable or disable GS1 DataBar Default Enabled Enable Disable GS1 DataBar Limited Formerly RSS Limited GS 1 DataBar Limited Defaults Set the GS 1 Databar settings to their default configuration by scanning this code GS 1 DataBar Limited On Off Scan one of the codes below to enable or disable GS1 DataBar Limited Default Enabled Enable Disable ...

Страница 52: ...Use the following commands in combination with numerical values to set the minimum and maximum length for allowed GS 1 Databar Expanded RSS Expanded barcodes Default minimum length 4 Default maximum length 74 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 4 and 74 or by scanning one of the barcod...

Страница 53: ...mands in combination with numerical values to set the minimum and maximum length for allowed Interleaved 2 of 5 barcodes Default minimum length 6 Default maximum length 30 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 2 and 55 or by scanning one of the barcodes below and then set the length by s...

Страница 54: ...ck Digit The scanner may look for a check digit to decide if the code is valid Interleaved 2 of 5 s USS Uniform Symbology Specification Check digit can be validated and if desired transmitted too Default Disabled Disabled USS Check validate USS Check validate transmit ...

Страница 55: ...n combination with numerical values to set the minimum and maximum length for allowed Matrix 2 of 5 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 55 or by scanning one of the barcodes below and then set the length by scanning the ...

Страница 56: ...ith numerical values to set the minimum and maximum length for allowed MSI barcodes Default minimum length 4 Default maximum length 48 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 4 and 48 or by scanning one of the barcodes below and then set the length by scanning the digit codes and the SAVE ...

Страница 57: ...ptional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit Default Enable One Check Digit but don t transmit Disable MSI Check Digits Enable One Check Digit but don t transmit Enable One Check Digit and transmit Enable Two Check Digits but don t transmit Enable Two Check Digits and transmit ...

Страница 58: ... disable UPC A Default Enabled Enable Disable UPC A Check Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or not to transmit it Default Transmit Check Digit Transmit UPC A Check Do Not Transmit UPC A Check UPC E1 Scan one of the codes below to enable or disable UPC E 1 Default Disabled Enable Disable ...

Страница 59: ...Check Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or not to transmit it Default Transmit Check Digit Transmit UPC E Check Do Not Transmit UPC E Check UPC E 0 Expanded Mode On Off UPC E 0 Expanded Mode expands the UPC E 0 code to the 12 digit UPC A format Scan one of the codes below to enable or disable U...

Страница 60: ...n with numerical values to set the minimum and maximum length for allowed PDF417 barcodes Default minimum length 1 Default maximum length 2750 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 2750 or by scanning one of the barcodes below and then set the length by scanning the digit codes and...

Страница 61: ...on with numerical values to set the minimum and maximum length for allowed MicroPDF417 barcodes Default minimum length 1 Default maximum length 366 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 366 or by scanning one of the barcodes below and then set the length by scanning the digit codes...

Страница 62: ...mbination with numerical values to set the minimum and maximum length for allowed Aztec barcodes Default minimum length 1 Default maximum length 3832 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 3832 or by scanning one of the barcodes below and then set the length by scanning the digit co...

Страница 63: ...th numerical values to set the minimum and maximum length for allowed Data Matrix barcodes Default minimum length 1 Default maximum length 3116 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 3116 or by scanning one of the barcodes below and then set the length by scanning the digit codes an...

Страница 64: ... numerical values to set the minimum and maximum length for allowed Maxi Code barcodes Default minimum length 1 Default maximum length 150 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 150 or by scanning one of the barcodes below and then set the length by scanning the digit codes and the ...

Страница 65: ...erical values to set the minimum and maximum length for allowed QR Code barcodes Default minimum length 1 Default maximum length 7089 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 1 and 7089 or by scanning one of the barcodes below and then set the length by scanning the digit codes and the SAVE...

Страница 66: ...45 degrees Horizontal Velocity Up to 230 inch 584 cm per second with 100 UPC at 4 inch 10cm distance Scan Contrast 45 minimum for Matrix codes 20 minimum reflectance Voltage Requirements 4 75 5 25VDC at imager Current Draw Max 5VDC Scanning Standby Inrush Normal 400mA 55mA 625mA Power Supply Noise Rejection Maximum 100mV peak to peak 10 to 100 kHz Temperature Ranges Operating 13 F to 122 F 25 C to...

Страница 67: ...he HS 1M handle 3 Tied to 5 Volt power 4 Supply Ground 5 6 7 5 Volt power connection 8 9 10 Data RS 232 1 Trigger Line 10 Pin Modular Plug 2 Shield GND connects to the HS 1M handle 3 4 Supply Ground 5 RxD In 6 TxD Out 7 5 Volt power connection 8 RTS Out 9 CTS In 10 Reference for the signal direction is the scanner ...

Страница 68: ... a detergent solution is used rinse with a clean lens tissue dampened with water only Cleaning the Scanner Housing The HS 1M is IP54 rated when the cable is attached This means that liquids and dusts will not penetrate into the housing However the scanner should not be submerged in water or other liquids It is also good practice to dampen the cleansing cloth vs spraying the scanner directly The HS...

Страница 69: ...e power to the host system OFF 2 Disconnect the HS 1M s cable from the terminal or computer 3 Locate the small triangular label that covers a hole on the bottom of the HS 1M near the cable connection point This hole is the cable release 4 Straighten one end of a paper clip 5 Insert the straight end of the paper clip into the small hole and press in This depresses the retention tab releasing the co...

Страница 70: ...a Return Material Authorization number RMA before returning the product If you need assistance installing or troubleshooting your scanner please contact the JADAK office in your area North America JADAK LLC 7279 William Barry Blvd North Syracuse New York 13212 3349 Telephone 1 315 701 0678 Fax 1 315 701 0679 E mail info jadaktech com Europe JADAK Europe BV Emmastraat 16 4811 AG BREDA The Netherlan...

Страница 71: ...harge except for return shipping to JADAK EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE JADAK S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIM...

Страница 72: ... radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna I...

Страница 73: ...e of February 26 2014 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits EMC DIRECTIVE 2014 30 EU as amended Council Directive of February 26 2014 on the approximation of the laws of the Member States relating to electromagnetic compatibility RADIO EQUIPMENT DIRECTIVE N A ROHS DIRECTIVE 2011 65 EU Directive 2011 65 EU o...

Страница 74: ...61000 3 2 2006 A1 2009 A2 2009 Harmonics current 16A EN 61000 3 3 2013 Flicker current 16A EN 62311 2008 EMF Safety Operating Characteristics Parameter Range Operating Voltage 4 75Vdc 5 25Vdc Operating Current Idle 100ma typical Scanning 450ma typical 500ma max Major component operating frequencies Crystal 24kHz Microprocessor core 400Mhz Memory Interface 133Mhz Switching power supplies 1Mhz 1 6Mh...

Страница 75: ...is topic CE Mark Indicates compliance with the Council Directive 93 68 EEC for the European Union WEEE Indicates that electrical and electronic equipment should be disposed of properly and separate from other types of waste RoHS Indicates the restriction of hazardous substances commonly used in electrical and electronic equipment The symbol indicates the device is compliant with the limits set for...

Страница 76: ...t All available commands are listed on the following pages as well as a brief description of what the parameter choices mean Some commands require further elaboration that can be found in the relevant sections in this manual For example the command to enable reading of Code 128 barcode symbols is 128ENAB 1 The full command to apply this setting to ROM is 128ENAB 1 CR Throughout this manual the ser...

Страница 77: ...g examples a bracketed notation depicts a non displayable response Query Goal What is the range of possible values for the Code 128 Max Length Send 128MAXL CR Response 0 55 CR Query Goal What is the default value for the Code 128 Max Length Send 128MAXL CR Response 55 CR Menu Bar Code Scanning As the JADAK HS 1M can be programmed by scanning menu bar codes or by sending serial commands to the engi...

Страница 78: ...28 0 0 0 0 1 C39DEFA Default Code 39 Parameters N A N A N A N A C39ASCI Code 39 Full ASCII Mode 0 0 0 0 1 C39CHEC Code 39 Check Digit 0 none 1 req 2 req xmit 0 0 0 0 1 2 C39ENAB Enable Code 39 Decoding 1 1 1 0 1 C39MAXL Max Code 39 Symbol Length 48 48 48 0 48 C39MINL Min Code 39 Symbol Length 0 0 0 0 48 C39CONV convert C39 to C32 Pharmacode 0 0 0 0 1 C39TRIO Code 39 Trioptic 0 0 0 0 1 CBRDEFA Defa...

Страница 79: ...EL BEEPPWR 0 to 1 0 Enable power up beep BEPGDRD 0 to 1 1 Enable good read beeper BEPLEVL 0 to 3 3 Beeper level 0 Off 1 Low 2 Medium 3 High BEPTIME 0 to 2 1 Beeper duration 0 short 1 medium 2 long BEPTONE 0 to 2 1 Beeper pitch 0 Low 1 medium 2 high C11CHEC 0 to 2 0 Enable Code 11 2 Character Check Digit C11DEFA Default Code 11 Parameters C11ENAB 0 to 1 0 Enable Decoding Code 11 C11MAXL 1 to 55 55 ...

Страница 80: ...3116 1 Min Data Matrix Symbol Length DNLDAPP Download a firmware moc file via XModem E13DEFA Default EAN13 Parameters E13ENAB 0 to 1 1 Enable Decoding EAN13 EA8DEFA Default EAN8 Parameters EA8ENAB 0 to 1 1 Enable EAN8 Decoding ELEDDUR 0 to 1000 1 Error LED duration in milliseconds EXP_MAX 1 to 7874 100 Max Exposure EXPMODE 0 4 0 Exposure Mode 0 Manual 4 Auto EXPTARG 48 to 212 120 Target White Valu...

Страница 81: ...h MSICHEC 0 to 4 0 MSI Enable Check Digit MSIENAB 0 to 1 0 Enable Decoding MSI MSIMAXL 4 to 48 48 Max MSI Symbol Length MSIMINL 4 to 48 4 Min MSI Symbol Length MULTSYM 0 to 1 0 Multiple Symbol mode NO_READ 0 to 1 0 Enable no read output NORDMSG Message output by the scanner for NO READ PDFDEFA Default PDF417 Parameters PDFENAB 0 to 1 1 Enable Decoding PDF417 PDFMAXL 1 to 2750 2750 PDF417 Max Symbo...

Страница 82: ...conds UE1ENAB 0 to 1 0 Enable UPC E1 Decoding UPADEFA Default UPC A parameters UPAENAB 0 to 1 1 Enable UPC A Decoding UPAXMIT 0 to 1 1 Transmit UPC A Enable Check digit UPEDEFA Default UPC E parameters UPEENAB 0 to 1 1 Enable UPC E 0 Decoding UPEEXPN 0 to 1 0 Enable UPC E Expanded Decoding UPEXMIT 0 to 1 1 Transmit UPC E 0 Check digit VIBMODE 0 to 4 0 Vibration Mode VIBNUMB 1 to 5 1 Vibration Puls...

Страница 83: ... JADAK flexpoint HS 1M User s Manual Page 82 Appendix B Programming Chart After you re done with setting the value with the barcodes above finish with scanning SAVE ...

Страница 84: ...unction code 1 in first symbol character position 2 Function code 1 in second symbol character position Example A Code EAN 128 bar code with Function 1 character FNC1 in the first position AIMID is transmitted as C1AIMID Data Matrix d 0 ECC 000 140 not supported 1 ECC 200 2 ECC 200 FNC1 in first or fifth position 3 ECC 200 FNC1 in second or sixth position 4 ECC 200 ECI protocol implemented 5 ECC 2...

Страница 85: ...lidated and stripped check digit Example An I 2 of 5 bar code without check digit 4123 is transmitted as I04123 PDF417 Macro PDF417 Micro PDF417 L 0 Reader set to conform to protocol defined in 1994 PDF417 Symbology specifications Note When this option is transmitted the receiver cannot reliably determine whether ECIs have been invoked or whether data byte 92DEC has been doubled in transmission 1 ...

Страница 86: ...5 S 0 No options specified at this time Always transmit 0 Example A D 2 of 5 bar code 4123 is transmitted as S04123 Maxicode U 0 Symbol in Mode 4 or 5 1 Symbol in Mode 2 or 3 2 Symbol in Mode 4 or 5 ECI protocol implemented 3 Symbol in Mode 2 or 3 Aztec Aztec Rune z 0 Aztec symbol C Aztec Rune symbol Trioptic Code 39 X 0 No option specified at this time Always transmit 0 Example A Trioptic bar cod...

Страница 87: ...int HS 1M User s Manual Page 86 Appendix D ASCII Conversion Chart For these HS 1M engines use 2 digit Hex values to create an ASCII character E g to create an F use 46 and to create an f use 66 Use 7A to create a z ...

Страница 88: ... JADAK flexpoint HS 1M User s Manual Page 87 Appendix D Cont d ASCII Conversion Chart ...

Страница 89: ... JADAK flexpoint HS 1M User s Manual Page 88 Appendix E Sample Bar Codes UPC A Codabar Code 128 Code 39 Code 93 Interleaved 2 of 5 PDF 417 Composite Code MicroPDF Aztec Data Matrix QR Code MaxiCode ...

Страница 90: ...e 7279 William Barry Blvd Emmastraat 16 North Syracuse NY 4811 AG Breda 13212 3349 The Netherlands Phone 1 315 701 0678 Phone 31 0 76 522 5588 Fax 1 315 701 0679 Fax 31 0 76 522 4747 e mail info jadaktech com e mail info jadaktech com www jadaktech com ...

Отзывы: