Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic

operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly
recommends purchasing and installing the optional automatic drain down valve.  The tank will be drained
automatically after each use after the water temperature lowers. Water filters and other conditioners are
strongly recommended if the water is of poor quality.

The Automatic Tank Drain Valve must be installed where the steam generator may be exposed to freezing

temperatures, e.g., in seasonal-use homes. (Water supply lines and water solenoid valve must not be allowed
to freeze.) This option prevents standing water from remaining in the tank. The tank will be automatically
drained through this valve when the water has cooled.

Read all warranty provisions before selecting a manual drain valve or the automatic drain down option.

Control and Temperature Sensor Cable Rough-in

A rough-in wiring kit is provided with unit to allow installer to locate and run wires to the temperature sensor
and digital controller before finish walls are installed.

Control Cable Rough-in

The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room.

String the 25' cable from the generator through 1/2" holes in the wall studs or ceiling joists to the controller location.
Note: Do not staple through or damage cable.  An option for tile rooms is to use the 1 gang rough-in box (provided)
and install at the desired control mounting location.  A mounting plate with proper 2" diameter hole is included with the
control kit. Tile up to the 2" hole in the mounting plate.

Temperature Sensor Rough-in

It is recommended that the sensor be mounted in the steam room 6" from the ceiling or below bottom of dome, but

not directly over the steam dispersion head or more than 7 feet above the floor. String the sensor cable from the sensor
location through 1/2" holes in the wall studs or ceiling joists to the generator location.  Leave 12" of slack at the sensor
location.  Note: Do not staple through or damage cable.

Leave a couple of feet of sensor and control cable free behind the steam generator to allow for removal

through  access panel for maintenance or servicing if necessary.

TANK DRAIN DOWN MANUAL VALVE (PROVIDED)

TO STEAM HEAD
(STEAM OUTPUT
FACTORY INSTALLED)

WATER SUPPLY

TO
TEMPERATURE
SENSOR

TO DIGITAL
CONTROLLER

NOTE: ALL COPPER PIPE SIZES ARE TO BE INDUSTRY NOMINAL SIZES
AND FITTINGS ARE NOT PROVIDED UNLESS OTHERWISE NOTED.

PRESSURE RELIEF VALVE

3/4 NPT (PROVIDED)

REDUCTION FROM 3/4 NPT
TO 1/2 NPT PERMITTED.

NOTE:  PRESSURE RELIEF DRAIN LINE,
DRAIN LOCATION AND METHOD AS
REQUIRED BY LOCAL CODES. (TO BE
1/2 INCH MINIMUM SIZE COPPER)

MANUAL WATER
SUPPLY SHUTOFF
VALVE (PROVIDED)

NOTE:  SITE DRAIN OR OTHER METHOD AS
REQUIRED BY LOCAL CODES. (WITH AUTOMATIC
DRAIN OPTION WATER DISCHARGED IS LESS
THAN 140

°

F.)

OPTIONAL AUTOMATIC
DRAIN VALVE

Содержание Steam & Shower Base SEDONA

Страница 1: ...SEDONA Steam Shower Base INSTALLATION OPERATING INSTRUCTIONS...

Страница 2: ...a steam enclosure shower or bath Read and follow manufacturer s safety information with all optional equipment The steam head is hot Do not touch the steam head or the steam within one foot distance...

Страница 3: ..._________________________ 8 Finish Materials ______________________________________________________________________ 8 9 Service Access _________________________________________________________________...

Страница 4: ...delivery of the products in good order to the carrier Refer any claims for damage to the carrier For definitions of warranty coverage and limitations refer to the published warranty information packa...

Страница 5: ...lling the base The use of materials that shim or provide a level installation are allowed provided the method used will ensure a level base that is supported from the bottom Materials that may be used...

Страница 6: ...sition when connecting to a drain line To allow steam generator removal for maintenance or service use a straight union DRAIN DOWN OUTLET OPTIONAL AUTOMATIC DRAIN DOWN VALVE DRAIN DOWN VALVE MOUNTED V...

Страница 7: ...ing joists to the controller location Note Do not staple through or damage cable An option for tile rooms is to use the 1 gang rough in box provided and install at the desired control mounting locatio...

Страница 8: ...installer s responsibility Drain leakage is excluded from the Jacuzzi Whirlpool Bath warranty of this product Slide the shower base into the framed opening and attach the shower base flange to the st...

Страница 9: ...unting screws to draw the control housing securely against the finished wall Do not over tighten the mounting screws Install the decorative cover plate by sliding the top of the cover plate over the t...

Страница 10: ...included with the sensor If the 7 8 holeisjaggedoriscuttoolargethetrimringmaybeused to cover the exposed edges Make sure that the sensor probe is pointing down once installed Tape the sensor in place...

Страница 11: ...with a wood or plastic edge Metal tools will scratch the surface Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge Paint tar or other difficult s...

Страница 12: ...le element If the steam room temperature drops more than 5 degrees both elements will automatically engage Operation of Your Digital Time and Temperature Control 1 Be sure the power circuit and water...

Страница 13: ...vice person For additional assistance or the factory authorized service person nearest you call the Service Department at 1 800 363 0251 This number is only for service for the steam generator The Tro...

Страница 14: ...12 Troubleshooting...

Страница 15: ...13 Wiring Diagram...

Страница 16: ...ble on a national basis for products of this type It is the responsibility of the installer owner to determine specific local code compliance prior to installation of the product Jacuzzi Whirlpool Sho...

Страница 17: ...those with manufacturing or workmanship defects for a period of five 5 years from the date of original installation except when the warranted product is installed in commercial locations such as clubs...

Страница 18: ...e use or inability to use a warranted product Some States do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the ab...

Страница 19: ...or acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to car...

Страница 20: ...zi Whirlpool Bath Warranty Service Department P O Drawer J Walnut Creek California 94596 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options...

Отзывы: