56
13
-
P
lace the lamp cover (
5
) on the nut (
9
).
F
inally, scre
w
the
cover (
2
).
The UV lamp contains mercury; in case of replacement,
discard the old lamp as specified by law.
14
-
T
urn on the hot tub master s
w
itch again and test the op-
eration of the device: the red led signals that the
C
learray® is
po
w
ered (and should al
w
ays be on)
w
hile the green one in-
dicates that the
UV
lamp is turned on.
t
Error/Display Messages
There are a number of unique functions designed into your
Jacuzzi spa to protect it from damage and/or to aid in trou-
bleshooting.
When an error occurs the spa will notify you by showing the
screen below and an error code. Following is a listing of all the
possible messages along with their meanings. Always insist on
genuine Jacuzzi replacement parts.
Note:
The error icon
(
) will remain on the screen as a
reminder. If the error is not taken care of or fixed, the error dis-
play will reappear in 2 hours.
“OPE N FLOW SWITCH”
(Heater is deactivated. The fil-
ter/circulation may also be deactivated.) The flow switch is mal-
functioning open, the circulation pump’s filter cartridge is exces-
sively dirty or an air lock condition has occurred at the circula-
tion pump intake.
I
Contact your authorized dealer or service organization.
“FLOW SWITCH”
(Heater is deactivated. The filter/circulation
may also be deactivated.) The flow switch is malfunctioning
closed.
I
Contact your authorized dealer or service organization.
“SHORTED HI-LIMIT TEMP SENSOR”
The hi-limit tem-
perature sensor is not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
“OPEN HI-LIMIT TEMP SENSOR”
The hi-limit temperature
sensor is not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
“SHORTED WATER TEMP SENSOR”
The temperature sen-
sor is not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
“OPEN WATER TEMP SENSOR”
The temperature sensor is
not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
“SHORTED AMBIENT TEMP SENSOR”
The temperature
sensor is not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
Monitors the controller temperature.
“OPEN AMBIENT TEMP SENSOR”
The temperature sensor
is not functional. Heater is disabled.
I
This must be repaired only by a qualified authorized service
organization or service technician.
Monitors the controller temperature.
“CLOSED FLOW SWITCH ON START-UP”
Flow switch is
non-functional. Closed or shorted flow switch on system start-
up (system disabled).
I
Contact your authorized dealer or service organization.
“FROZ E N ON START-U P”
Flow switch is non-functional.
Shorted flow switch on system start-up (system disabled) and
freeze condition detected.
I
Contact your authorized dealer or service organization.
“COOL WAR N I NG”
Spa water is more than 52°F/11 °C
cooler than the temperature set point, the circulation pump and
heater will automatically activate to provide freeze protection. The
spa will stay in this mode until the water temperature reaches
46°F/8°C below the set temperature.
I
No corrective action is necessary.
Note: The heater icon (
) will be blinking and the error icon
(
) will be displayed under the temperature.
GER!
ER
LB
.
NDNE
SS
P
o
w
er
on
L
amp
on
The flow switch is malfunctioning open. Heater
is disabled. The circulation pump’s filter is
excessively dirty, or an air lock has occurred at
the circulation pump intake. Contact your
authorized dealer or service organizations.
FLOW ERROR
96
6:45 PM
ON
1
2
ON
96
6:45 PM
ON