Page 54
J-400
3. Frequent Mode: Activates two cycles at 8:00 PM and 8:00 AM
every
day
. Each cycle will last 10 minutes for a total of 20 minutes every
day. To activate this mode, tap next to “Frequent.” Time and
duration cannot be altered.
4. Tap
to return to the Heat & Filter Menu. Tap again to return to the
Settings Menu.
12.4 Cleanup Cycle
The cleanup cycle occurs once per day at 12:00 pm (noon) for 2 minutes.
This is not user programmable. The Jets Pump 1 and the Circulation
Pump will turn on for one minute and then shut off. Then Jets Pump 2 will
turn on and run for 1 minute then shut off. Lastly, Jets Pump 3 will turn
on and run for 1 minute then shut off. The feature can be deactivated by
turning off the corresponding jets pump that is running.
12.5 Blow-Out Cycle
This cycle will purge the air from the plumbing lines normally caused by
draining and filling the spa. The Jets Pump 1 and the Circulation Pump
will turn on for
1 minute and then shut off. Then Jets Pump 2 will turn on
and run for 1 minute then shut off. Lastly, Jets Pump 3 will turn on and
run for 1 minute then shut off. The feature can be deactivated by turning
off the corresponding jets pump that is running. This cycle will
only
occur
at start up and after exiting a service lock.
12.6 Water Care Programming
Water care is crucial to maintaining a healthy and clean spa. The
CLEAR
RAY
water purification system leads the way by sanitizing the
water using a UV light bulb. Your spa can be programmed to remind you
when to check and replace certain components.
From the Settings Menu, tap or to highlight the “Water Care” menu
tab in Orange, Figures 12.6a and 12.6b. Tap
Water Care
to the enter the
menu. Then select one of the features.
A.
Programming the CLEARRAY UV Bulb Timer
The CLEAR
RAY
UV bulb has a life expectancy of 1 year. A timer
activates when power is applied and begins a countdown starting at
365 days. Once the timer expires, an error message will appear of the
display, the UV bulb must be replaced and the timer needs to be reset.
Tap
CLEARRAY
65
(Figure 12.6b) to enter the Programming Menu.
Note:
The days are stored in memory if the power is interrupted.
ProClarity
60
Water Refresh
60
ProClarity Depth 50
CLEARRAY
65
Water Care
Heat & Filter
Water Care
Wi-Fi
SETTINGS
Figure 12.6a
Figure 12.6b