Page 16
J-400
7.0 Power Requirements
Jacuzzi® spas are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
They are configured at the factory. The most common electrical
connections are listed below:
• All North American 60 Hz Models only:
These models come set for
50A logic. If you prefer, your qualified technician can perform a logic
modification that allows the spas to operate on a different electrical
service, see table footnotes below. Reference page 85.
North American Models (60 Hz)
Voltage:
240 VAC/40A
*
240 VAC/50A
**
240 VAC/60A
***
Max. Current Draw:
1-Pump System:
26A
36A
N/A
2-Pump System:
26A
37A
48A
3-Pump System:
N/A
37A
48A
Frequency:
60 Hz
60 Hz
60 Hz
Number of Wires:
3
3
3
*
In 40A configuration, the heater
will not operate
while either jets pump is
running.
Not recommended for the J495.
**
In 50A configuration, the heater
will operate
when one jets pump is
running, but
will not operate
if more than one jets pump is running.
This
is the factory setting.
***
In 60A configuration the heater
will operate
when two jets pumps are
running, but
will not operate
if three jets pumps is running.