![Jacuzzi J - 210 Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/jacuzzi/j-210/j-210_owners-manual_3354773014.webp)
page 0
US/Canada J-230 2-Pump Model (60Hz)
240V/40A*
240V/50A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A, 2-Pole
50A, 2-Pole
60A, 2-Pole
*
In 40A configuration, the heater
will not operate
while either jets
pump is running in high speed.
Note: pump 2 runs only in high speed.
**
In 50A configuration, the heater
will not operate
while both jet pumps
are running in high speed.
Note: pump 2 runs only in high speed.
This is the factory setting.
***
In 60A configuration, the heater
will operate
while both jet pumps are
running in high speed.
Note: pump 2 runs only in high speed.
US/Canada J-210 / J-220 1-Pump Convertible Model (60Hz)
120V/15A*
240V/30A*
240V/40A**
Voltage:
20 VAC
240 VAC
240 VAC
# of Wires:
3 (5A GFCI Cord
4 (Hard
4 (Hard
US only*)
Wired only)
Wired only)
Frequency:
60Hz
60Hz
60Hz
Current Draw:
2A
2A
30A
Circuit Breaker:
5A, -Pole
30A, 2-Pole
40A, 2-Pole
For 240 VAC Heater Operation:
Move the red wire on the main terminal
strip (TB) from position # to position #3. Make certain wires are con-
nected exactly as shown in Figure-D (page 3) before applying power.
Failure to do so will result in damage to the circuit board and/or related
components and void the manufacturer’s warranty.
*All Canadian spas must be hard wired (120 VAC or 240 VAC) per
CSA Canadian standards. (page 4).
*
In 5A/30A configuration, the heater
will not operate
at the same
time as the high-speed jets pump.
The factory setting is 120V/15A.
**
In 40A configuration, remove the jumper JP #-2 on the circuit board
to allow the heater to operate at the same time as the
high-speed jets pump (page 33).
6.0 Power Requirements
Jacuzzi
®
spas are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service listed in
the tables below. If you prefer, your dealer can perform a minor circuit
board modification to allow your spa to accept an electrical service other
than the factory setting.