60
-
Do not turn off the switch located upstream of the shower
enclosure until the final washing cycle for the steam genera-
tor has stopped.
- During the Turkish bath, it is possible to use the manual hydraulic
functions (shower, showerhead and/or spray jets); the audio system
and the Cromodream® function can also be activated (the alarm is
always available).
Q
TOP model
Press the "Turkish bath" key, the following configuration will ap-
pear on the display:
10/30
If a few seconds pass without pressing any key, the control
panel will return to the “awaiting instructions” mode and then
“stand-by”: press the “on/off” key to reactivate the control panel
and then the "Turkish bath" key to activate the desired function.
X
Press the “>” key to select the “water-pitcher” symbol (outline
on a white background).
10/30
The first number under the symbol indicates the number of
Turkish baths carried out (in this case, 10); the second indicates the
maximum number of Turkish baths possible before a scale-removal
cycle must be run (see also “Delaying activation of the scale-remov-
al cycle”).
X
Then press the “on/off” key to activate the function: the
"Turkish bath" key starts to flash and the display shows the
countdown of the remaining amount of time for pouring the
scale removal liquid.
Scale removal cycle
T
o resolve any problems caused by the formation of scale in the
steam generator, the shower cubicle comes equipped with a
function that makes it possible to reduce the formation of any in-
crustations, thanks to a specific product.
To clean the steam generator, run the scale-removal cy-
cle roughly every 20-25 Turkish baths (see also “Delay-
ing activation of the scale-removal cycle”).
The cycle lasts approx. 10 hours: during this period, the various
functions are available (except the Turkish bath).
X
Make sure that the waterfall, the whirlpool jets and/or the
Turkish bath are not active; also make sure that the control panel
is in the
“awaiting instructions” mode
(refer to the “Activating
the electronic functions” chapter).
X
Prepare the scale removal mixture as indicated.
Frame 100-120:
50 ml
Frame In2:
100 ml
750 ml
H
2
O
Note
- where the water is very hard, we recommend doubling the quantity
of scale removal product normally advised.
Содержание frame in2
Страница 1: ...9WS 1ERYXIR MSRI 327 6 6 32 96 9WI 1EMRXIRERGI 4 6 900 9XMPMWEXMSR RXVIXMIR 327 6 6 73 2 JVEQI...
Страница 2: ......
Страница 3: ...MR Avvertenze e indice 4 5 Warnings and index 6 7 Recommandations et sommaire 8 9...
Страница 107: ......