38
Management of functions
by means of pneumatic push buttons
The pneumatic push buttons provided, which should be installed
near the spa where the user can reach them, make it possible to
manage the following functions:
- Hydromassage (pump 1 + pump 2).
- Blower (if present in the system).
- Underwater spotlight(s)
- Water heating.
When installed, these push buttons are normally disabled, since
the control panel is activated in the factory.
To enable the pneumatic push buttons, you must first activate
the system with the
"start" key (3)
and then press and hold the
"hand" key (2)
, for about 3 seconds, until it goes off.
If the "hand" key is already off, it means that the pneumatic
push buttons have already been activated.
When the pneumatic push buttons are active, the keys of the
control panel are deactivated, with the exception of those dedi-
cated to programming/settings.
HYDROMASSAGE
Press the pneumatic push button
“p1”
, and/or the push but-
ton
“p2”
, to start one or both of the hydromassage pumps
(the
push buttons may however be connected differently during the
installation phase)
. Each of the two hydromassage pumps man-
ages a certain number of jets (see drawings).
Press the pneumatic push button again to shut off the corre-
sponding pump.
A default maximum operating time of 20 minutes has been
memorized. This “timeout” can be modified from 1 to 99 min-
utes, but it can also be bypassed. In this case the hydromas-
sage pumps must be shut off using the pneumatic push button
or the main switch, or with the start/stop key of the control pan-
el. The "timeout" can be modified only from the control panel,
with the system in "standing by for commands" status ("start"
key off) and by means of the system parameter
P6(-)
(see in-
formation on
setting general system parameters
).
Values between
01
and
99
represent the maximum operating
time, in minutes, of the hydromassage pumps, after which they shut
off automatically. When set to
0
, the "timeout" is eliminated.
When the hydromassage pumps and/or the blower are switched
on, the ozonator (if present) is switched off, and remains off for 15
minutes after the last shutdown (see chapter on ozonator).
Vice versa, when the hydromassage pumps and/or the blow-
er are turned on, if the filtering pump is off it is automatically
started and kept running for 15 minutes after the last shutdown
(see chapter on water filtering). If the pumps or blower are on, it
means there are people in the tub, and therefore the water needs
to be filtered to keep it clean.