background image

SECTION 4. GENERAL 

CLEANER 
INFORMATION

CAUTION

To prevent damage to the cleaner, to adhere to the 
following guidelines:

•  Remove the cleaner from the pool after the cleaning 

cycle is completed.

•  Store out of direct sunlight or inclement weather.

•  Never lift the cleaner out of the pool by the fl oating 

cable. 

•  Take additional care when lifting the cleaner out of the 

pool. It becomes heavier when fi lled with water.

•  Always remove the cleaner from pool when super 

chlorinating or adding acid.

•  Do not handle cleaner while it is in operation

IMPORTANT

•  Always fully submerge the cleaner head before you 

begin operation.

•  Clean the fi lter canister after each cleaning cycle.

•  Do not leave your cleaner in the pool on a 

permanent basis.

•  At the end of each cycle, remove the cleaner from 

the pool. 

•  Start at the cleaner head and untangle any coils in 

the cable before storing the cleaner.

The robotic cleaner includes a safety feature that 
automatically stops the cleaner if a cleaning cycle starts 
but it is not submerged in water. For pools equipped 
with a beach area, this safety feature is programmed 
to drive the cleaner in reverse and back into the pool 
when the impeller is out of the water. 

4.1  INSTALL AND SUBMERGE THE 

CLEANER

1. 

With the control box plugged into a power 
outlet, spread the fl oating cable across the pool 
deck until you reach the middle of the pool 
length.

WARNING: Do not use an extension cord

2. 

At the center point, submerge the cleaner in 
the pool and hold in the vertical position to 
release any air trapped inside. 
(Figure 3).

1

Figure 3.  Submerge the Cleaner Vertically

3. 

Ensure the unit sinks to the bottom of the pool 
and does not fl oat (Figure 4).

2

Figure 4.  Cleaner Sinking to the Bottom of the 

Pool

7

OWNER'S MANUAL

Содержание EN27 Series

Страница 1: ...ol equipment by the jurisdiction in which the product will be installed where such state or local requirements exist In the event no such state or local requirement exists the maintainer must be a pro...

Страница 2: ...pment into an outlet on circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expres...

Страница 3: ...rmation 7 Install and Submerge the Cleaner 7 Control Box Buttons 8 Start Stop Cleaning and Select Cleaning Mode 8 Removal from Pool 8 Using the Lift System 8 Maintenance 9 Cord Tangling 9 Clean the Fi...

Страница 4: ...t least five 5 feet from the edge of the pool spa water In Canada the Canadian Electrical Code CEC requires a minimum distance of 3m 10 ft to be maintained between the pool edge and the control box Ne...

Страница 5: ...ner patterns can be seriously scratched or abraded simply by rubbing the surface with a pool brush Ink from the pattern can also rub off during the installation process or when it comes into contact w...

Страница 6: ...a ground fault circuit interrupter GFCI Contact a certified electrician if you cannot verify that the receptacle is protected by a GFCI Do not use an extension cord to connect the control box Do not...

Страница 7: ...er from the pool Start at the cleaner head and untangle any coils in the cable before storing the cleaner The robotic cleaner includes a safety feature that automatically stops the cleaner if a cleani...

Страница 8: ...rline 2 hours 30 minutes With the cleaner submerged in the water press to begin operation Press again to interrupt and cancel an in progress cleaning cycle 4 4 REMOVAL FROM POOL The Lift System is des...

Страница 9: ...can help to avoid cable challenges IMPORTANT Cleaner power cable may become tangled if correct procedure is not followed after each cleaning cycle NOTE Place all of the floating cable in the water to...

Страница 10: ...2 CLEAN THE FILTER CANISTER The filter canister should be cleaned after each cycle 1 Remove the cleaner from the water and let the remaining water drain 2 Unlatch the cleaner cover to access the canis...

Страница 11: ...e control box Figure 14 Untangle the power cable 5 4 REPLACING BRUSHES The cleaner is fitted with brushes with a wear indicator Figure 15 raised groove becomes partially flattened indicating excessive...

Страница 12: ...New Brush on Roller 4 Thread each tab into the slot provided and gently feed it through until the heel comes out at the other side of the slot Figure 19 4 Figure 19 Pull Tabs Through Each Slot 5 Use a...

Страница 13: ...h the cable connection area Rotate the track by a quarter of a turn in the same direction until it rotates smoothly If this does not resolve the problem contact your local retailer for a diagnostic re...

Страница 14: ...k that the outlet to which the control box is connected is receiving electricity Cycle not started Press the Start button to initiate a cleaning cycle Reset needed Disconnect the unit power and reconn...

Страница 15: ...NOTES 15 OWNER S MANUAL...

Страница 16: ...the property of their respective owners Jacuzzi may add to change or remove any part of these materials at any time without notice Reproduction in whole or inpart without written permission is prohibi...

Отзывы: