 – BUILT-IN DIAGNOSTICS 

 

BUILT-IN DIAGNOSTICS 

 

The 

Commander II Model JC5 

Control Box contains a way to display a diagnostic report on its operation.  It allows the user to view 

the salt concentration, the water temperature, and the Electrolytic Cell voltage and amperage.  This is provided for a technician to 
evaluate the performance of the Commander II Model JC5 without the need for special equipment.  The values are measured by 
counting the number of flashes of the lights, as described below. 
 
 

To access and interpret the diagnostics, follow this procedure: 

 

To start the diagnostic procedure, press and hold both the UP and DOWN buttons at the same time.  Hold them pressed until 
the output display lights go out, leaving just the bottom light illuminated (about 5 seconds). 

 

1.

 

The 

first

 value to be displayed is the 

salt concentration

 in Parts Per Million (PPM).  This value is measured by counting 

the number of flashes of the top 3 lights.  In the case of salt, the top light is not used, the next to the top flashes the 1000’s 
digit and the third light flashes the 100’s digit in ppm. 
 

Example: 2 flashes/pause/8 flashes/pause Read: 2,800 PPM 

 

2.

 

The 

second

 value is the 

water temperature

 in degrees Fahrenheit.  When this is displayed, the second light from the 

bottom is on.  The top light flashes the 100’s digit, the next the 10’s digit and the next the units of temperature. 

 

 

Example: 8 flashes/pause/6 flashes/pause Read: 86 Degrees F 

 

3.

 

When the 

third

 light from the bottom is on, the 

cell voltage

 is displayed.  The top light is not used.  The second light 

flashes the 10’s digit and the third the units of voltage. 

 

 

Example: 2 flashes/pause/8 flashes/pause Read: 28 Volts 

 

4.

 

When the 

fourth

 light is on the 

cell current

 in amperes is being displayed.  The top light displays the 10’s digit (not 

normally used), the next the units and the third the tenths of amps. 

 

 

Example: 5 flashes/pause/5 flashes/pause Read: 5.5 Amps 

 
 

The diagrams below summarize the built-in diagnostic displays. 

 

 

 
 

14

  

  

 

x100 

°

F  

  x10 

SALT TEMPERATURE

VOLTS AMPS 

 

 

 

 x1000 ppm 

 x10 

°

x10 V 

x1 A 

 

 

 

 x100 ppm 

 x1 

°

x1 V   

x0.1 A 

 

  

 

(Amps) 

 

  

 

 

 

(Volts) 

 

  

 

 

 

(Temperature) 

 

  

 

(Salt) 

 

Содержание 27842.01

Страница 1: ...S ACT This cell must only be used on this model of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device COMMANDER II Model JC5 before u...

Страница 2: ...in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Competition Inc 12775 rue Brault Mirabel Qu bec Canada J7J 0C4 Tel 450 437 2420 REGISTRATION NO 2784...

Страница 3: ...ing Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to...

Страница 4: ...Unit Model Number Commander II Serial Number ____________________________ Cell Model Number JC5 Serial Number ____________________________ Factory Direct Customer Assistance HOTLINE 1 450 437 2420 FA...

Страница 5: ...n Canada 5 WARNING Maintain water chemistry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supe...

Страница 6: ...ri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt...

Страница 7: ...page 10 for Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to t...

Страница 8: ...agram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth...

Страница 9: ...erify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or eq...

Страница 10: ...water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on N...

Страница 11: ...tain a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the...

Страница 12: ...dium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name a...

Страница 13: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel...

Страница 14: ...a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner...

Страница 15: ...d ordered separately Red Cap Plug for JC5 cell cord 19050 3 6m 12 ft Cell Cord 952 1 Union O Ring 19013 Cell JC5 Nut Half only 2 pc for 50 mm 2 in S x S Union Thread Half Only for 50 mm 2 in S x S Uni...

Страница 16: ...Cell B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive...

Страница 17: ...the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The s...

Страница 18: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Отзывы: