Section 5a

 – TROUBLESHOOTING

 

 

TROUBLESHOOTING 

 

PROBLEM

 

 

CAUSE

 

SOLUTION 

 

1) 

Insufficient SANITIZER Production.

 

 

A)

  The test kit reagents or test strips are old or expired. 

A) 

Retest with new Reagents or Strips. 

B) 

The unit is set too low in relation to SANITIZER demand. 

B)

  Turn up the output setting. 

 

C)

  The circulation run time is insufficient. 

C) 

Increase your pump run time. 

 

D)

  The bather load has increased. 

D) 

Same solution as 

(B)

 or add a Non-Chlorine Shock  

 

   

  containing 

Potassium 

Monopersulfate to supplement. 

 

E)

  The body of water being sanitized leaks. 

E) 

Repair the leak and rebalance as needed. 

 

F)

 Low Salt. 

F)

  Check the residual salt level and adjust as needed. 

 

G)

 “Cell Power” selection not matched to the cell installed. 

G)

  Follow the SET UP procedures to match the cell, see page 7. 

 

H)

  SANITIZER loss due to intense sunlight 

H)

  Check your stabilizer level and adjust if needed. 

2) 

Scale Build-up within the Cell.

 

 

A) 

The water being sanitized contains high pH, total 

A)

  Calculate Saturation Index to assure balanced water.  

 

 

alkalinity and calcium hardness levels. 

 

Adjust chemicals and clean the Cell.  See pages 9 & 11. 

 

 

(Cell scales within 2 – 3 weeks) 

 

B)

  Power Supply not reversing polarity. 

B)

  Contact the factory for Warranty Status/Procedures. 

 

 

(Cell constantly scales within 3 – 5 days) 

3) 

DC Plug and Cell Terminals Burned.

 

 

 

A)

  The Cell terminals are wet due to a leaking cell body. 

A)

  Contact the factory for Warranty Status/Procedures. 

 

B) 

The Cell plug is not securely pushed onto the cell 

B) 

Ensure the Cell cord plug is pressed completely onto the 

 

 

terminals, allowing moisture to seep into the plug. 

 

Cell terminal.  Check the terminals and clean with a dry  

 

 

   

 

 

cloth to remove all dirt and corrosion. 

4) 

Premature Cell Failure (Requires Replacement Cell).

  

 

 

A)

  Abnormally high Cell usage due to an insufficient 

A) 

Check the stabilizer level and adjust to recommended levels. 

 

 

Stabilizer (Cyanuric acid) level. 

 

B)

  Excessive Scale/Debris in the Cell. 

B) 

See Section 2 above.  

 

C) 

“Cell Power” selection not matched to the Cell installed. 

C)

  Follow the SETUP procedures to match the cell, see page 7. 

5) 

White Flakes in the Water.

 

 

A)

  This occurs when excessive calcium hardness is 

A)

  Visually inspect Cell for scale build-up and clean the cell as 

 

 

present.  Usually due to water chemistry imbalance. 

 

described on page 11.  Adjust your water chemistry. 

6) 

No Power to the Control Box.

 

 

A)

  Internal Fuse blown. 

A)

  Check and replace fuse.  See page 10. 

 

B)

  Circuit Breaker tripped. 

B)

  Check the power going to the Control Box.  Reset the  

  

 

 

 

Circuit 

Breaker. 

7)

 

SERVICE Light (Single RED Flash and Flow-OK light off).

 

 

 

A) 

 

Tri-Sensor Defective. 

A)

  Contact the factory for Warranty Status/Procedures. 

 

 

B) 

 

Insufficient Flow Min. (94.5 lpm) 

(25 gpm) 

B)

 

Ensure your Filter and Cell are clean of debris. 

 

   

   

 

Check all valves that might divert flow away from the cell. 

8)

 

SERVICE Light (Double RED Flash)(SANITIZER is producing).

 

 

 

A) 

  High Cell Volts with Low Amps 

A)

  Check cell for calcium build-up or scale deposits. 

 

   

   

 

Cell is depleted and needs replacement. 

 

   

   

 

Cell cord is loose or defective.  Ensure that the cord is firmly  

 

   

   

 

attached to the cell.  Check the Banana Plug connections. 

9)

 

SERVICE Light (Triple RED Flash)(SANITIZER production halted). 

 

(Microprocessor version V1.4 or older)  

 

 

A) 

High Cell volts with

 

Extremely Low Amps. 

A)

  Heavily scaled cell or failed cell. 

 

(Microprocessor version V1.5 or newer)  

 

 

A) 

Improperly wired or failed Power Supply. 

A)

  Ensure voltage input matches wiring connection (page 5). 

10)

 

SERVICE Light (Quadruple RED Flash)(SANITIZER is producing). 

 

A) 

Tri-sensor or tri-sensor cord is loose or defective. 

A)

  Inspect and tighten or replace.  

11)

 

LOW SALT Light activated (SANITIZER is producing) .

 

 

A)

  Salt level Low (below 2,5 g/l (2500 ppm)). 

A)

  Check with Salt test strips or meter and adjust as needed. 

12)

 

ADD SALT Light activated (SANITIZER production halted).

 

 

A)

  Salt level extremely low (below 2.0 g/l (2000 ppm)). 

A)

  Check with Salt test strips or meter and adjust as needed. 

13)

 

Unable to set output to a high level.

 

 

A)

  Temperature is too low (below 15.6C (60F)). 

A)

  The Pool Pilot has limited output to protect the cell.  

 
 

13

Содержание 27842.01

Страница 1: ...S ACT This cell must only be used on this model of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device COMMANDER II Model JC5 before u...

Страница 2: ...in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Competition Inc 12775 rue Brault Mirabel Qu bec Canada J7J 0C4 Tel 450 437 2420 REGISTRATION NO 2784...

Страница 3: ...ing Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to...

Страница 4: ...Unit Model Number Commander II Serial Number ____________________________ Cell Model Number JC5 Serial Number ____________________________ Factory Direct Customer Assistance HOTLINE 1 450 437 2420 FA...

Страница 5: ...n Canada 5 WARNING Maintain water chemistry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supe...

Страница 6: ...ri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt...

Страница 7: ...page 10 for Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to t...

Страница 8: ...agram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth...

Страница 9: ...erify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or eq...

Страница 10: ...water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on N...

Страница 11: ...tain a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the...

Страница 12: ...dium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name a...

Страница 13: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel...

Страница 14: ...a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner...

Страница 15: ...d ordered separately Red Cap Plug for JC5 cell cord 19050 3 6m 12 ft Cell Cord 952 1 Union O Ring 19013 Cell JC5 Nut Half only 2 pc for 50 mm 2 in S x S Union Thread Half Only for 50 mm 2 in S x S Uni...

Страница 16: ...Cell B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive...

Страница 17: ...the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The s...

Страница 18: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Отзывы: