Assembling the PH kit
Inspect the equipment components thor-
oughly as follows:
• Suction filters, in-line filters – clean them.
• Hoses – check them for holes; make sure
they are not folded.
• Pressure regulator components – make
sure the valve seat, the valve and spring are
not worn or clogged by impurities.
• Pump – check for leaks and the correct lev-
el of the lubricating oil.
• Nozzles – make sure they are not worn,
their flow rate do not differ more than 10%,
and the nozzle filters are clean
1. ONCE ALL THE COMPONENTS HAVE BEEN
CHECKED, THE SPRAYER CAN BE CALI-
BRATED.
2. Set 50m in the area that will be treated.
3. Fill the sprayer tank with clean water.
4. Position the machine at least 5m before
the first mark.
5. Activate the TDP to 540 rpm.
6. Choose the working speed.
7. Open spraying on the chemical control.
8. When the machine crosses the first mark,
start the stopwatch.
9. When the machine crosses the second
mark, stop the stopwatch.
10. Write down the time the sprayer took to
travel the 50 meters.
11. On uneven terrains, repeat this opera-
tion serval times and calculate the aver-
age.
Calibrating the sprayer (practical method)
Содержание ARBUS 400
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 28: ......
Страница 30: ......
Страница 36: ......
Страница 40: ......
Страница 42: ......
Страница 78: ......
Страница 80: ......
Страница 98: ......
Страница 100: ......
Страница 103: ...ARBUS400 6 103 6 WARR ANT Y Techinicalinspectionsregistration Date hours No Description Techinical Dealer...
Страница 104: ......
Страница 106: ......