4 CONTROLS
en-43
4.2.23.49 FAN DRIVE ___________________________________________________________
Select the Fan Drive
and accept
.
The normal fan operation is based on engine
temperature. Fan speed will increase as
engine temperature increases.
When engine temperature exceeds a set value
or timer ends, the reverse fan cycle will start.
Fan will stop the forward rotation, operate in
reverse rotation for 10 seconds and return to
forward rotation. Timer will automatically
restart after each reverse fan cycle.
To prevent reverse fan rotation select
OFF
and select
. To accept.
To use manual start the reverse fan cycle, select
Manual and select
. To accept.
Press the and – to increase or decrease Timer Set-Up. Select
. To accept.
4.2.23.50 BRIGHTNESS ADJUST__________________________________________________
Use the buttons below the + and - icons on the screen to increase and decrease
the brightness.
P i n M e n u
C r u i s e C o n t r o l
C r o s s C u t
Ve h i c l e S p e e d
C h a n g e P I N
I n c l i n o m e t e r
S e t D e f a u l t P a r a m e t e r s
D r i v e M o d e s
F a n D r i v e
min
F a n D r i v e M e n u
3 0
Timer Set-Up [min]
Manual
OFF
%
0
100
+
-
+
-
B r i g h t n e s s