OPERATING CAPACITY:
Selection A
Racks per Hour
53
Dishes per Hour
1325
Glasses per Hour
1325
Selection B
Racks per Hour
29
Dishes per Hour
725
Glasses per Hour
725
Selection C
Racks per Hour
20
Dishes per Hour
500
Glasses per Hour
500
OPERATING CYCLE (SECONDS):
Minimum (other cycle times are available)
LT HT
Wash Time
45
45
Rinse Time
14
15
Total Cycle Time
59
60
High Temperature Ventless
Wash Time
45
Rinse Time
15
Dwell Time
2
Condensate Removal
30
Total Cycle Time
92
Tank Capacity:
Rinse Tank (gallons)
N/A
3.0
Rinse Tank (liters)
N/A 11.4
Wash Tank (gallons)
14
8.0
Wash Tank (liters)
30.3
30.3
ELECTRICAL REQUIREMENTS:
Wash Motor HP
2.0
NOTE: Always refer to the machine data plate for
specific electrical and water requirements.
The material provided on this page is for
reference only and is subject to change
without notice.
WATER REQUIREMENTS:
Tempstar HH & Tempstar HH Ventless:
Wash Temperature (minimum) (°F)
150
Wash Temperature (minimum) (°C)
66
Rinse Temperature (minimum) (°F)
180
Rinse Temperature (minimum) (°C)
83
Inlet Water Temperature:
12kW Rinse Heater (°F)
140
12kW Rinse Heater (°C)
60
14kW Rinse Heater (°F)
110
14kW Rinse Heater (°C)
44
14KW
Ventless (°F)
40-70
14KW Ventless (°C)
4.4-21
Flow Pressure (PSI)
20±5
Water Line Size (NPT)
3/4"
Drain Line Size (NPT)
1 1/2"
Tempstar HH NB/Tempstar HH S:
Wash Temperature (minimum) (°F)
150
Wash Temperature (minimum) (°C)
66
Rinse Temperature (minimum) (°F)
180
Rinse Temperature (minimum) (°C)
83
Inlet Water Temperature (°F)
180
Inlet Water Temperature (°C)
83
Flow Pressure (PSI)
20±5
Water Line Size (NPT)
3/4"
Drain Line Size (NPT)
1 1/2"
Tempstar HH LT:
Wash Temperature (minimum) (°F)
120
Wash Temperature (minimum) (°C)
49
Rinse Temperature (minimum) (°F)
120
Rinse Temperature (minimum) (°C)
49
Inlet Water Temperature (°F)
120
Inlet Water Temperature (°C)
49
Flow Pressure (PSI)
20±5
Water Line Size (NPT)
1/2"
Drain Line Size (NPT)
1 1/2"
STEAM REQUIREMENTS:
Coil Size
3/4"
Steam Flow Pressure (PSI)
10-20
Consumption @ 15 PSI (lbs./hr.)
45
SPECIFICATIONS
OPERATING CAPACITIES
2
Содержание TempStar Series
Страница 2: ......
Страница 28: ...PARTS 22 TOP MOUNTED CONTROL BOX ASSEMBLY 30 28 29 25 22 21 26 33 34 36 1...
Страница 36: ...PARTS HOOD ASSEMBLY 30 1 5 4 2 3 6 7 10 8 9...
Страница 60: ...PARTS 460 VOLT MACHINE TRANSFORMER MOUNTING BOX 54...
Страница 61: ...PARTS PARTS 55 EXHAUST FAN CONTROL OPTION...
Страница 62: ...PARTS TEMPSTAR HH VENTLESS HEAT REVOCERY SYSTEM ASSEMBLY 1 2 3 15 16 4 10 9 5 11 8 12 7 17 6 56...
Страница 66: ...ELECTRICAL SCHEMATICS SOLID STATE TEMPSTAR HH TOP MOUNT CONTROLS 208 230V 60HZ 1 3 PHASE 60...
Страница 67: ...ELECTRICAL SCHEMATICS 61 TEMPSTAR HH UNIVERSAL TIMER 208 230V 60HZ 1 3 PHASE...
Страница 68: ...ELECTRICAL SCHEMATICS 62 SOLID STATE TEMPSTAR HH TOP MOUNT W CYCLE SWITCHES 460V 60HZ 3 PHASE...
Страница 69: ...ELECTRICAL SCHEMATICS TEMPSTAR HH UNIVERSAL TIMER 460V 60HZ 3 PHASE 63...
Страница 70: ...ELECTRICAL SCHEMATICS TEMPSTAR HH S UNIVERSAL TIMER 208 230V 60HZ 1 3 PHASE 64...
Страница 71: ...ELECTRICAL SCHEMATICS TEMPSTAR HH 208 230V 60HZ 1 3 PHASE 65...
Страница 72: ...ELECTRICAL SCHEMATICS TEMPSTAR HH 460V 60HZ 3 PHASE 66...
Страница 73: ...ELECTRICAL SCHEMATICS TEMPSTAR HH S 208 230V 60HZ 1 3 PHASE 67...
Страница 74: ...ELECTRICAL SCHEMATICS TEMPSTAR HH NB 208V 230V 50 60HZ 1 PHASE 68...
Страница 75: ...ELECTRICAL SCHEMATICS TEMPSTAR HH NB LT 208V 230V 50 60HZ 1 PHASE 69...
Страница 76: ...70 ELECTRICAL SCHEMATICS OPTIONS SDI OPTION...
Страница 77: ...ELECTRICAL SCHEMATICS OPTIONS EXHAUST FAN HOOKUP DRAIN QUENCH OPTIONS 71...
Страница 78: ...Tempstar HH Series Installation Operation Technical Manual 07610 002 23 32 Issued 09 14 07...