TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
REMEDY
Dishmachine runs
continuously in the
wash cycle.
Machine is in delime mode.
Wash cycle delay timer is faulty.
Wash cycle delay timer settings are
not correctly adjusted.
Cam timer is faulty.
Change operation mode from DELIME to NORMAL position.
During the wash cycle, the cam timer will move for the first 30 seconds
of the wash cycle. The cycle delay timer will then cause the cam timer to
stop, in order to increase the length of the wash cycle. The red light on
the delay timer is in control of the cam timer. If the red light is not turning
on (only during cycles B, C or D), replace the cycle timer.
If the wash cycle delay timer and rotating cam timer are working correctly,
the time cycles on the delay timer may be incorrectly adjusted. Adjust
the delay potentiometer corresponding to the B, C or D cycle. Rerun the
appropriate cycle and see if the adjustment has made any change in the
length of the cycle. If not, replace the cycle delay timer.
Confirm that the wash cycle delay timer is functioning correctly (see
above). Confirm that the timer motor is receiving power. If it is, replace
the motor and/or timer assembly. Make sure there are no obstructions
which limit the rotation of the cam timer.
Dishmachine will not
fill after the door is
closed. Power "ON"
light is illuminated.
Faulty rinse solenoid valve.
Faulty door switch.
Fouled/faulty high level probe.
Repair or replace valve as required.
Verify the wiring of the switch; if correct, replace the switch.
Clean probe if fouled. If clean and not working, replace.
Dishmachine will not
fill after the door is
closed. Power "ON"
light is not illuminated.
Service breaker tripped.
Machine not connected to power
source.
Faulty power source.
Reset. If the breaker trips again, contact an electrician to verify the amp
draw of the machine.
Verify that the machine has been properly connected to the power
source.
Verify the wiring of the switch; if correct, replace switch.
Dishmachine will not
fill after the door is
closed. Power "ON"
light is not illuminated.
Service breaker tripped.
Machine not connected to power
source.
Faulty power source.
Reset. If the breaker trips again, contact an electrician to verify the amp
draw of the machine.
Verify that the machine has been properly connected to the power
source.
Verify the wiring of the switch; if correct, replace switch.
Wash or rinse heater
does not work.
Faulty heater element.
Faulty heater contactor.
Misadjusted/faulty thermostat(s).
Check element for continuity; if open, replace the heater.
Replace the contactor.
Verify the operation and setting of thermostats; replace if necessary.
Dishmachine fills
slowly and/or rinse is
weak.
Clogged or obstructed rinse arms.
Low incoming water pressure.
Y-strainer is clogged.
Remove and clean the rinse arms.
Adjust the water pressure regulator to ensure that there is 20±5 PSI flow.
Clean out the Y-strainer.
Rinse water is not
reaching required
temperature.
Faulty rinse heater.
Misadjusted/faulty thermostat(s).
Rinse thermometer is defective.
Check element for continuity; if open, replace heater.
Verify operation and setting of thermostats; replace if necessary.
Replace thermometer.
20
Содержание TempStar Series
Страница 2: ......
Страница 28: ...PARTS 22 TOP MOUNTED CONTROL BOX ASSEMBLY 30 28 29 25 22 21 26 33 34 36 1...
Страница 36: ...PARTS HOOD ASSEMBLY 30 1 5 4 2 3 6 7 10 8 9...
Страница 60: ...PARTS 460 VOLT MACHINE TRANSFORMER MOUNTING BOX 54...
Страница 61: ...PARTS PARTS 55 EXHAUST FAN CONTROL OPTION...
Страница 62: ...PARTS TEMPSTAR HH VENTLESS HEAT REVOCERY SYSTEM ASSEMBLY 1 2 3 15 16 4 10 9 5 11 8 12 7 17 6 56...
Страница 66: ...ELECTRICAL SCHEMATICS SOLID STATE TEMPSTAR HH TOP MOUNT CONTROLS 208 230V 60HZ 1 3 PHASE 60...
Страница 67: ...ELECTRICAL SCHEMATICS 61 TEMPSTAR HH UNIVERSAL TIMER 208 230V 60HZ 1 3 PHASE...
Страница 68: ...ELECTRICAL SCHEMATICS 62 SOLID STATE TEMPSTAR HH TOP MOUNT W CYCLE SWITCHES 460V 60HZ 3 PHASE...
Страница 69: ...ELECTRICAL SCHEMATICS TEMPSTAR HH UNIVERSAL TIMER 460V 60HZ 3 PHASE 63...
Страница 70: ...ELECTRICAL SCHEMATICS TEMPSTAR HH S UNIVERSAL TIMER 208 230V 60HZ 1 3 PHASE 64...
Страница 71: ...ELECTRICAL SCHEMATICS TEMPSTAR HH 208 230V 60HZ 1 3 PHASE 65...
Страница 72: ...ELECTRICAL SCHEMATICS TEMPSTAR HH 460V 60HZ 3 PHASE 66...
Страница 73: ...ELECTRICAL SCHEMATICS TEMPSTAR HH S 208 230V 60HZ 1 3 PHASE 67...
Страница 74: ...ELECTRICAL SCHEMATICS TEMPSTAR HH NB 208V 230V 50 60HZ 1 PHASE 68...
Страница 75: ...ELECTRICAL SCHEMATICS TEMPSTAR HH NB LT 208V 230V 50 60HZ 1 PHASE 69...
Страница 76: ...70 ELECTRICAL SCHEMATICS OPTIONS SDI OPTION...
Страница 77: ...ELECTRICAL SCHEMATICS OPTIONS EXHAUST FAN HOOKUP DRAIN QUENCH OPTIONS 71...
Страница 78: ...Tempstar HH Series Installation Operation Technical Manual 07610 002 23 32 Issued 09 14 07...