7
INSTRUCTIONS
INSTALLATION
CHEMICAL FEEDER
EQUIPMENT
PRIMING CHEMICAL
FEEDER PUMPS
WARNING: Some of the
chemicals used in
dishwashing may cause
chemical burns if they
come in contact with skin.
Wear protective gear when
handling these chemicals.
If any skin comes in
contact with these
chemicals, immediately
follow the instructions
provided with the
chemicals for treatment.
TO PREPARE
CHEMICAL FEEDER
PUMPS FOR
OPERATION
WARNING!
CHLORINE-BASED SANITIZERS CAN BE DETRIMENTAL TO THIS MACHINE
IF THE CHEMICAL SOLUTION IS TOO STRONG. SEE A CHEMICAL
PROFESSIONAL TO ENSURE THE DISPENSER IS SET UP CORRECTLY.
This equipment is not recommended for use with deionized water or other aggressive fluids.
Use of deionized water or other aggressive fluids will result in corrosion and failure of
materials and components and will void the manufacturer's warranty.
The bottom of the chemical container cannot be located any higher than 8” from the
floor. If the unit is equipped with the 6” or 18” table stand, the highest position will
respectively be 14” or 26” from the floor.
The AVENGER HT-E dishmachine is supplied with detergent and rinse aid chemical
feeder pumps.
The AVENGER LT-E dishmachine is supplied with detergent, rinse aid and sanitizer
chemical feeder pumps.
Locate the open ends of the chemical tubes with the tube stiffeners and place each
one in the appropriate container.
A. Red Tubing = Detergent B. Blue Tubing = Rinse Aid
C. White Tubing = Sanitizer
Chemical feeder pumps need priming when the machine is first installed or if the
chemical lines have been removed and air is allowed to enter. CAUTION! Water
must be in the sump and wash tank prior to the dispensing of chemicals. Sanitizer in
concentration is caustic and may cause damage without dilution.
1. Verify that the proper chemical tube stiffener inlet is in the proper container.
2. Use the prime buttons located on the control panel at the bottom of the unit to
prime each pump. The buttons are clearly marked as to which chemical feeder
pump they are assigned to.
3. To prime the pumps, press the button until the chemical can be observed entering
the pump.
4. Detergent is dispensed as required during the wash cycle by the timer. The
amount of detergent may need to be increased or decreased depending upon water
quality and type of detergent.
5. Rinse additive is dispensed as required into the final rinse. The amount of rinse
additive may need to be adjusted depending upon water hardness & results.
6. Please refer to "Programming Instructions for Chemical Feeder Pumps" for
instruction on adjusting the chemical feeder pumps on the Programmable Logic
Controller (PLC).
Содержание AVENGER HT-E
Страница 2: ......
Страница 35: ...29 CONTROL PANEL PARTS 1 8 3 2 4 5 6 7 ...
Страница 41: ...35 115V CONTROL BOX PARTS ITE 2 3 4 5 6 7 8 9 13 14 15 4 4 2 5 6 8 9 7 3 1 1 ...
Страница 46: ...40 WASH DRAIN MOTOR ASSEMBLY PARTS 10 11 12 13 1 2 3 4 5 9 8 6 7 ...
Страница 54: ...48 RINSE TANK ASSEMBLY PARTS 8 7 6 5 2 3 4 1 ...
Страница 58: ...52 SCHEMATICS 115 VOLT ELECTRICAL DIAGRAM ...
Страница 59: ...53 SCHEMATICS 208 230 VOLT ELECTRICAL DIAGRAM ...
Страница 60: ...54 SCHEMATICS 480 VOLT ELECTRICAL DIAGRAM ...