Quick Installation and Startup Guide

Insert a small coin 

(dime) in the release 

slot located on the 

bottom of the 

thermostat and gently 

twist the coin to 

release the thermostat 

from the subbase.

Before mounting 

the thermostat 

subbase to the 

wall, pull the 

wires from the 

HVAC unit 

through the wire 

access hole. 

Mount and level 

the subbase 

using the 

furnished 

hardware.

After all wiring is landed, attached the thermostat to the subbase and apply 24 Volt power.

Land the remaining HVAC wires to the thermostat terminals based on the specific equipment configuration. If an indoor or outdoor remote sensor is used, wire the sensor to the T T terminals.

The sensor wiring must be a separate 18-2 cable and should not exceed 200’ in length from the sensor to the thermostat.

Refer to the thermostat Installation Manual for Advanced Installer settings that might be 

required for the specific equipment applications as well as confirming that the baud rate is 

set at 19.2 and the Modbus address is set at 01.

To simplify installation, 

the transceiver comes 

pre-wired to the 

thermostat terminals with 

leads for the HVAC unit 

24 Volt hot and common. 

Use wire connectors to 

secure each lead to the 

HVAC unit 24V ‘R’ and 

24V ‘C’ wires. Land the 

remaining HVAC unit 

wires to their proper 

terminals. Dress all wires 

so that they do not come 

in contact with the 

thermostat PC board.

Set the system slide switches to match the 

HVAC equipment application:

* For heat pump systems that energize the reversing valve on a call for heating (B), turn switch 4 ON.

SWITCH 6 MUST BE OFF AND SWITCH 8 MUST BE ON

Use the provided 

6 transceiver log 

to document the 

serial number 

located below the 

bar code on the 

back of the 

thermostat 

subbase. Also 

note the 

thermostat 

location.

Turn the two 

Modbus 

configuration 

slide switches 

to ON.

. . . . . .

1 2 3 4 5 6 7 8

ON

. . . . . .

1 2

ON

. . . . . .

1 2 3 4 5 6 7 8

ON

. . . . . .

1 2

ON

SLIDE SWITCH SETTING

HVAC SYSTEM

6=

1 HEAT / 1 COOL

8=

5=ON 

4=OFF 

3=OFF 

2=OFF 

1=OFF 

7=OFF 

2 HEAT / 2 COOL

6=

5=ON 

3=ON   

2=OFF 

1=OFF 

4=OFF 

8=

7=OFF 

6=

8=

1=OFF 2=ON   3=OFF 4=OFF 5=ON 

7=OFF 

2 HEAT / 1 COOL

HEAT PUMP (O)*     

6=

8=

4=OFF 4=ON 

3=ON   

2=ON   

1=OFF 

7=OFF 

OFF

ON

OFF

ON

3 HEAT / 2 COOL

HEAT PUMP (O)*     

OFF

ON

OFF

ON

W2

G3

Y2

G2

W1

O/B

Y1

G1

R

B

A

24       24C        

T

T          

REV

VALVE

FAN 1

RELAY

TRANSCEIVER

THERMOSTAT OPTIONAL

SENSOR

LINE

COMP 1

AUX

RELAY

HEAT

24 V

W2

G3

Y2

G2

W1

O/B

Y1

G1

R

B

24C        

24       

A

T

T          

REV

VALVE

FAN 1

RELAY

TRANSCEIVER

THERMOSTAT OPTIONAL

SENSOR

LINE

COMP 1

RELAY

COMP 2

AUX

RELAY

HEAT

24 V

W2

G3

Y2

G2

W1

O/B

Y1

G1

R

B

24       24C        

A

T

T          

HEAT 1

RELAY

FAN 1

RELAY

TRANSCEIVER

THERMOSTAT OPTIONAL

SENSOR

LINE

COMP 1

RELAY

COMP 2

RELAY

HEAT 2

RELAY

24 V

Multi-Stage Heat / Cool

Single Stage Heat / Cool

3 Heat / 2 Cool Heat Pump or Dual Fuel

2 Heat / 1 Cool Heat Pump or Dual Fuel

LAND HVAC

UNIT WIRES

TO APPROPRIATE

TERMINALS

W2 Y2  W1 Y1  G    R

O/B

24   24C  B A T    T

C

R

The HVAC 24 Volt power must be OFF during wiring!

MN:1000140 R:100

SN: AU111400000

BACK OF SUBBASE

MOUNTING

TRANSCEIVER

(Push in on sides to release cover)

HOLES

FRONT OF SUBBASE

W2

G3

Y2

G2

W1

O/B

Y1

G1

R

B

24       24C        

A

T

T          

HEAT

RELAY

FAN 1

RELAY

TRANSCEIVER

THERMOSTAT OPTIONAL

SENSOR

LINE

COMP 1

RELAY

24 V