Figure 6 

STEP 2 

 
Install the Main Flex Fuel Line 

onto the 3/8” flared connection on the 

Searing Side Burner manifold (Fig. 2 above). (Sealant not required). 
 

PROPANE GRILLS:

 The inlet fuel line from the Propane Tank MUST   

Not 

Exceed 11” Water Column. If in doubt, please contact a   

professional Gas Fitter to check inlet pressure to your Grill. 
 

NATURAL GAS GRILLS

: The fuel line which delivers Natural Gas   

from your home to the grill, must not exceed 4.5

” Water Column. 

(Also see Gas 

Conversion’. PP.7) 

 
 
STEP 3

 

 

 
Drop Searing Side Burner into cabinet, and while doing so, route the Main Flex Fuel Line under your Jackson Built In 
Grill.   

 
 
STEP 4 
 

Remove brass cap from Fuel Inlet Manifold under the built in grill (Fig. 3a pp.5). Connect Searing Burner Main Flex 
Line to the built In grill manifold (Fig. 4 pp.5). Before using your grill, perform a thorough leak test as per the following 
section.

 

 
 
 
 

LEAK TESTING: 

 
STEP 1 

 
Turn on Gas. (Do NOT turn on any burners). 

 
 
 

STEP 2 

 
Mix a solution of liquid dish soap and water (or use profession leak detector liquid). 
Spray or brush thoroughly on all fuel line connections (Fig. 6). If soap bubbles are 
generated at any connection, tighten the fitting and re-test. If a leak is detected   
that cannot be repaired, immediately 

turn off the gas

 and contact your dealer for   

further assistance. 
 
 
 
 
 

LIGHTING INSTRUCTIONS 

 
1. 

Turn the main gas supply ON. 
 

2. 

Depress the side burner control knob down slightly and turn 

SLOWLY

 counter clock wise until the 

‘click’ of 

the igniter is heard. (This side burner has a built in ignition system).   

 

3. 

If the side burner does NOT light, turn the control knob to the OFF position and try again. 

 

4. 

Once the burner has lit, turn the control knob counter clock wise to the desired heat level. 

 

To turn the unit off, turn the gas control clockwise to the OFF position. 

 

TECH TIP 

It is recommend that a Certified Gas 
Fitter be used to install fuel lines 
and other fuel related components. 

 

 

!WARNING! 

Check fuel pressure before operating your 
Grill & Side burner. Over pressure could 
cause injury and property damage,

 

 

Содержание JGSBSEAR

Страница 1: ...www jacksongrills com FOR OUTDOOR USE ONLY WARNING If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 Open lid 4 If odor continues keep away from appliance and immediately call your gas supplier fire department WARNING 1 Do not store or use gasoline or other flammable liquids in the vicinity of this appliance 2 Do not store disconnected propane tanks in the vicinity of ...

Страница 2: ...ing Instructions 7 Natural Gas Conversion 8 Warranty 8 CERTIFICATION TESTING This side burner has been tested by Labtest Certification LC and has been tested to ANSI Z21 58a 1198 CGA 16a M98 and Certified for Canada and the USA NOTE The use and installation of this product must conform to local codes In the absence of local codes use the National Fuel and Gas Code ANSI A223 1 Storage and Handling ...

Страница 3: ...d burns unless wearing protective gear Pot holders gloves BBQ mittens etc 7 It is essential to keep the valve compartment burners and circulating air passages clean and free of obstructions and debris Inspect the grill before each use 8 Do not store any spare propane cylinders within 10 feet of this Side Burner 9 Please note that propane LP is explosive under pressure heavier than air and settles ...

Страница 4: ...ht hand side of the unit as it will interfere with the rotisserie otherwise WARNING SHUT OFF FUEL before installing this side burner assembly Lid With Handle JH 000 Flex fuel Line JF 8 Side Burner Body call dealer Manifold JF 80 Gas Valve JF 02 Orifice JF 001 NAT JF 003 LP Shoulder Bolt JH 001 Elbow JF 004 Knob JK 14 Grid Support JG 22 Cook Grid JG 18 Bezel JK 15 Burner JB 14 Electrode JF 21 Main ...

Страница 5: ...t will allow the side burner to drop into place STEP 3 Install the included Main Flex Fuel Line onto the 3 8 flared connection on the Searing burner gas manifold Fig 2 NOTE Sealant is NOT required Next insert the Main Flex Fuel Line through the hole in right pedestal wall of your Jackson Grill Note that the hole should be factory equipped with a grommet to protect the fuel line Remove the Brass Ca...

Страница 6: ...1 Cut fabricate a hole in the cabinet to size as shown in Figure 6 Cut Out Dimensions High Lighted in Yellow These dimensions are the actual cut out dimensions for the built in units in non combustible applications WARNING SHUT OFF FUEL before installing this side burner assembly ...

Страница 7: ...turn on any burners STEP 2 Mix a solution of liquid dish soap and water or use profession leak detector liquid Spray or brush thoroughly on all fuel line connections Fig 6 If soap bubbles are generated at any connection tighten the fitting and re test If a leak is detected that cannot be repaired immediately turn off the gas and contact your dealer for further assistance LIGHTING INSTRUCTIONS 1 Tu...

Страница 8: ...7 3 Lightly coat threads of the Natural Gas Orifice with Gas Teflon Tape or Gas Fitting Pipe Dope 4 Install Natural Gas Orifice in the Brass Elbow at the Searing Burner Fig 8 Tighten as required 5 After Natural Gas had been connected to the built in grill turn gas on and check all gas connections per Leak Testing previous page TECH TIP Do NOT over tighten the orifice as the threads may break off ...

Страница 9: ...manship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year Jackson Grills Inc reserves the right to fully disengage all obligations with respect to this Limited Warranty by refunding the original warranted purchaser the original wholesale price of the warranted parts Genuine Jackson parts must always be used us...

Отзывы: