background image

 

 

LIGHTING INSTRUCTIONS: 

 

1.  Inspect the hose and burner for wear or damage. DO NOT LIGHT THE FIRE PIT IF DAMAGE OR WEAR IS 

FOUND. 

 

2.  PROPANE: Attach the regulator assembly to your propane cylinder. NOTE: Make sure your propane cylinder 

valve is closed.   

 

3.  Attach the campfire regulator assembly to your propane cylinder by   

threading the black plastic QCC fitting clockwise onto the cylinder   
valve until hand tight (fig 8). 

 

4. 

NATURAL GAS: check to ensure that the gas source connection is set at 7” 
water column. Then, connect the natural gas hose to the pre-installed gas 
connection at the natural gas source on the home.

 

 

5.  When connecting the Patio Fire to a gas source for the first time, always 

perform a leak test using a soap and water solution.   

 

 
 
 
 
 
 

a)  Apply the soap solution to the connections at either end of the hose and regulator assembly. 

 

b)  PROPANE: Open the LP cylinder valve; if bubbles start to form between the valve and the hose there is 

a leak. Shut off the gas, then remove and reattach the hose. If bubbles continue to form indicating the 
leak is still there, SHUT OFF the gas and contact the nearest dealer. If no bubbles are seen, leave the 
gas on, and continue to step 6. 

 

c)  NATURAL GAS: Open the gas line valve, if bubbles start to form between the valve and the hose there is 

a leak. Shut off the gas, then remove and reattach the hose. If bubbles continue to form indicating the 
leak is still there, SHUT OFF the gas and contact the nearest dealer. If no bubbles are seen. Leave the 
gas on, and continue to step 6. 

 

6.  Place a lit match or equivalent on the log set near a burner port (fig 10).

 

 

 

7.  Stand clear of the burner ports, and slowly turn on the gas. (fig 9

; shows the propane valve in the “off” 

position). This Patio Fire 

may light with a “WOOF’; this is normal and is not dangerous. 

 

8.  The flame intensity can be lowered by slowly closing the gas valve.

 

 

 

9.  TO SHUT OFF Patio Fire: simple turn the On/Off Valve to the off position (red arrow, fig 9). Then shut off fuel 

source.    Note: this unit must be shut off for 5 minutes before restart is permitted. 

 

 

!WARNING! 

NEVER use an open flame to check for 
gas leaks; Injury, death and/or property 
damage may result.

 

  On/Off Valve 

TECH TIP

 

To apply the soap solution 
to check for leaks, use a 
medium sized artist or 
hobbyist type paint brush.   

 

Fig. 8 

Fig. 9 

Fig. 10 

Содержание JFP-LP

Страница 1: ...1 For Portable Gas Camp Fire Model JFP LP Version Jan14 OWNER S MANUAL for Patio Fire Important Notice Please read ALL safety notices on PP 3 PP 4 before assembling or operating this Patio Fire ...

Страница 2: ...enance 9 Storage 10 11 Parts List 11 Warranty 12 SPECIFICATIONS Input 46 500 BTU h 13 6 KW h Manifold Pressure 11 inch W C 2 74 KPa Maximum Gas Supply Pressure 13 inch W C 3 50 KPa LP Orifice Size 47 NG Orifice Size for Conversion Purposes 35 Recommended propane cylinder size 20 lbs Run Time using a 20 lb Cylinder of Propane 8 10 hours Minimum distances to combustibles sides 16 406mm Minimum dista...

Страница 3: ...and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative the controls burners and circulating air passageways of the appliance be kept clean 6 Failure to follow manufacturer s instructions may void your fire insurance and or warranty 7 Do not use this Patio Fire until it is COMPLETELY assembled all parts are securely installed and lea...

Страница 4: ...henever the cylinder is not in use Only install the type of dust cap on the propane cylinder valve outlet this provided with the cylinder valve Other types of caps may result in leakage of propane gas 20 Never fill any LP Gas Cylinder more than 80 percent full Dented and rusted propane cylinders may be hazardous and must be checked by a propane gas supplier before use 21 WARNING if the information...

Страница 5: ...odel and serial number at hand Patio Fire Model JFP LP Portable Patio Fire Serial Number _________________ Write your serial number here for future reference OWNER REGISTRATION Please take the time to fill out and return a Warranty Registration Card or on line at www jacksongrills com or simply fill in the form below and mail or fax to Jackson Patio Fires Customer Support Tel 1 888 287 3333 or 106...

Страница 6: ...ely fastened to the campfire body For use with propane gas The LP gas supply cylinder must be shut off and disconnected when this appliance is not in use The LP gas supply cylinder s to be used with this campfire must be arranged for vapor withdrawal and must include a collar to protect the cylinder valve The LP gas supply cylinder s must be constructed and marked in accordance with the specificat...

Страница 7: ...the burner as shown Finally scatter the embers over the exposed areas of the burner pan Where possible cover the burner gas slots with embers this will result in a more esthetically pleasing flame fig 7 WARNING Installing the logs embers in any arrangement other than shown here in this manual will result in UNSAFE burn characteristics Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Burner Gas lots ...

Страница 8: ... leak is still there SHUT OFF the gas and contact the nearest dealer If no bubbles are seen leave the gas on and continue to step 6 c NATURAL GAS Open the gas line valve if bubbles start to form between the valve and the hose there is a leak Shut off the gas then remove and reattach the hose If bubbles continue to form indicating the leak is still there SHUT OFF the gas and contact the nearest dea...

Страница 9: ...hose assembly complete with orifice mount fitting from the Patio Fire body fig 12 8 Using an 8 mm wrench remove the brass propane orifice from the orifice mount fitting on the end of the propane hose Set it aside and install the supplied natural gas orifice Red arrow fig 13 9 Remove the brass orifice mount with the orifice from the propane hose and install the assembly into the threaded female on ...

Страница 10: ...ed Use a soft brush attachment on a vacuum to clean the whole unit Re install the burner and refer to page 5 6 to re install the logs and embers 7 This campfire hose and regulator assembly must be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1 2 psi 3 5kPa 8 This campfire must be isolated from the gas supp...

Страница 11: ...free area of not less than 1 2 square inch per pound 3 2 sq cm kg of stored fuel capacity and not less than a total free area of 10 square inches 64 5 sq cm If ventilation openings at floor level are in a sidewall there shall be at least two 2 openings The bottom of the openings shall be at floor level and the upper edge no more than 5 inches 127 mm above the floor The openings shall be equally si...

Страница 12: ...ndle Assembly JP 02 Lid JP 03 Wind guard JP 11 Log set JP 04 Embers 2 bags Not Shown JP 05 LP Burner JP 06 Body JP 07 LP Hose Regulator Assy JP 08 LP Orifice Mount Assembly JP 09 Bungee Cord n a Owner s Manual JP 01 JP 02 JP 03 JP 05 JP 06 JP 07 JP 09 JP 08 ...

Страница 13: ...orrosion or discoloring by heat and abrasive or chemical damage resulting from use of harsh cleaners Genuine Jackson parts must always be used use of parts supplied by other manufacturers will nullify the warranty The installation must be done in accordance with the installation procedures described in the included owner s manual Jackson Patio Fires or its parties will not be responsible for the i...