Quick Installation Guide

 

Thank  you  for  purchasing  the  Jacarta  interSeptor  Pro-XP  Environmental  Monitoring 

System and sensors. 

 

This installation guide provides instructions for installing the 

interSeptor Pro-XP 

on 

your network. For all other aspects of product use, please see the  full User Manual 

that can be downloaded from:

 

www.jacarta.com/support/resources

 

Should  you  require  any  assistance  during  the  installation  process,  please  email 
[email protected] or call +44 (0) 1672 511125. Free technical support is available 

during normal UK business hours, 9am-5.30pm, Monday to Friday. Outside of these 

hours, we will aim to respond to you as soon as possible.

 

 

 
Index: 
 
Safety Information & Emissions Notice

………

.

…………

..3 

 
Quick Installation Instructions

………………………………

.4 

 
Sensor Installation Instructions

……………………………

..6 

 

Appendix I: Daisy-Chaining Multiple Sensors

……………

 
 
 
 

 
 
 
 
 

 
 
 
 

 
 
 

Содержание InterSeptor Pro-XP

Страница 1: ...___________________________ 1 INTERSEPTOR PRO INTERSEPTOR PRO INTERSEPTOR PRO XP XP XP Quick Installation Guide Quick Installation Guide Quick Installation Guide www jacarta com support jacarta com 44...

Страница 2: ...the full User Manual that can be downloaded from www jacarta com support resources Should you require any assistance during the installation process please email support jacarta com or call 44 0 1672...

Страница 3: ...exterior Do not use the equipment in the following environments i Humidity higher than 80 ii Temperature higher than 50 C or lower than 0 C iii Near objects which transmit strong electromagnetic waves...

Страница 4: ...u option Login by entering the following default credentials Username iSPro Password admin 5 Select the General Settings menu option and then select Network Settings From here you can change and save...

Страница 5: ...e Power Security etc can be connected to the dry contact ports on the Temperature Humidity sensors via the screw terminals 2 x Go Probe sensors per T H sensor 8 Sensor settings to trigger alerts etc c...

Страница 6: ...ta GO PROBE sensors security voltage water leak detection dry contact PIR vibration smoke etc should be attached to the interSeptor Pro XP via the screw terminals on the Temperature Humidity sensors T...

Страница 7: ...m VOLTAGE SENSOR PIR SENSOR VIBRATION SENSOR The relevant Alarm 1 or 2 should be configured as Normal Open in the browser via the EMD set up screens Device Management Device Configuration When power i...

Страница 8: ...perature Humidity Sensors up to a maximum of 8 sensors per chain please refer to the following table for the appropriate dip switch settings NB Pin 6 is for future use and should always be in the Off...

Отзывы: