Model 36960-2 Series
Model 36960-2 Series
ELECTRIC BILGE PUMPS
FEATURES
•
Self-Priming
•
Diaphragm Design Allows Dry Running
•
Built-in Hydraulic Pulsation Dampener
•
Pumpgard
®
Strainer Included with Pump
•
Corrosion Resistant Materials Throughout
for Sea Water Service
•
Meets USCG Regulation 183.410 and
ISO 8846 MARINE for Ignition Protection
PRODUCT SPECIFICATIONS
Open Flow . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 GPM
Vertical Dry Suction Lift . . . . . . . . . . . 7 Feet (2.1 m)
Ports . . . . . . . . . . . . . . . . . . . . . . . . 3/4” Slip-on Hose
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 lb. (3.2 kg)
INSTALLATION
MOUNTING
Mount upright in a dry location (above highest bilge
water level) on a solid surface. Selection of a dry, cool,
ventilated location will generally extend pump life. Locate
Pumpgard strainer in accessible spot in suction hose.
PLUMBING
For intake and discharge use 3/4” ID non-collapsible
hose. Keep intake and discharge line free of kinks and
restrictions. To protect pump from debris, use the 3/4” in-line
strainer, Model 36200-0000 in the intake line from the bilge.
WIRING
Wire pump in a circuit independent of all other electrical
fixtures. Use stranded copper wire. Install fuse in posi-
tive circuit. See table for recommended wire and fuse
size. See diagram for wiring instructions. Use a 10 amp-
rated switch (44960-Series). After installation, it is rec-
ommended that voltage be checked at the motor termi-
nals with motor operating under full load. Voltage should
not be less than 90% of rated motor voitage.
STANDARD MODELS
Model
Voltage
Current
Fuse Size
36960-2000
12 Vdc
6 Amp
8 Amp
36960-2010
24 Vdc
5 Amp
7 Amp
WINTER STORAGE
When possible it is preferred that the complete pump be
removed and stored in a warm dry place. If this is not
possible the pump must be completely drained, hoses
removed and pump run until all water is expelled.
WIRE SIZE TABLE
Model
Model
Wire Length Between
36960-2000 36960-2010
Battery and Motor
12 Volt
24 Volt
1-25 ft.
12 AWG
14 AWG
26-50 ft.
10 AWG
14 AWG
6.31 (160)
7.50 (191)
7.31
(186)
4.75 (111)
DIMENSIONAL DRAWING
Inches (Millimeters)
BATTERY
MANUAL
AUTOMATIC
OFF
FUSE/
BREAKER
PUMP
Automatic Bilge Switch
Model 34875-0000 or
Model 30295-1000
per instructions
3-Way Switch
44960-0000
WIRING DIAGRAM FOR
AUTOMATIC OPERATION