background image

The JK-84 “Oasis” wireless alarm kit 

1 / 2 

MKE59904  

The JK-84 “Oasis” wireless alarm kit

Installation  of  the  JK-84  kit  shall  only  be  undertaken  by  technicians 
holding  a  certificate  issued  by  an  authorized  distributor.  This  simplified 
installation  manual  only  describes  the  basics,  for  more  details  see  the 
manuals of particular devices. 

1. 

Factory-default pre-enrolled devices  

Address 

Device 

Note 

05 

JA-83M door detector  Delayed reaction 

06 

JA-83P PIR detector 

Delayed reaction 

48 

RC-86 keyfob 

Buttons 

and

 pre-enrolled 

49 

JA-81F keypad unit 

Connect a magnetic door sensor 
to its IN input. 

50 

JA-80L indoor siren 

 

 

JA-82KR 

Pre-enrolled to the JA-80L 

2. 

Control panel and keypad installation 

1.  Attach the Control Panel (CP) to the desired location. 
2.  Connect  back-up  battery  to  the  CP  (attach  it  securely  with 

adhesive tape). 

3.  Connect the mains to the CP – its green LED will start flashing  
4.  Connect up the batteries in the JA-81F keypad – service mode 

should  be  displayed  (if  not,  disconnect  the  keypad  batteries,  check 
that  the  control  panel  is  powered  up  and  reconnect  the  keypad 
batteries).
 
The  internal  keypad  menu  can  be  entered  in  Service  mode  by 
holding the 

?

 key. Using the arrows on keys 1 and 7 you can scroll 

thought this menu: 

Display 

Key 

Description 

Tamper ON 

 

Disable / Enable the tamper sensor  

(only for service purposes) 

Door chime ON 

 

Disable / Enable sound when IN triggered 

Beeper ON 

 

Disable / Enable system sounds 

Brightness 

 

Sets the display brightness   0 - 9 

Contrast 

 

Sets the display contrast   0 - 9 

Edit text 

 

Entry to keypads text editing 

English 

 

Sets English (reload default texts)  

To exit the menu, press (exiting also occurs after 10 seconds’ inactivity) 

o

  If  you  exit  Service  mode  accidentally,  it  can  be  re-entered  by 

keying in 

∗∗∗∗

 0 8080. 

o

  Close  the  keypad’s  flip  cover  to  save  the  battery  while  in  the 

service mode. 

Before  attaching  the  JA-81F  keypad,  test  that  it  functions  correctly  at 
the  desired  location.  We  recommended  wiring  up  a  magnetic  door 
sensor  
(provided  with  the  kit)  to  the  keypad’s  IN  input.  This  will  ensure 
that  the keypad  is  “woken  up”  whenever  the  door  is  opened  (to  indicate 
system  status,  to  make  entrance  delay  beeps  and  to  have  the  access 
card reader ready for reading cards). 

3. 

Installing the detectors and the siren 

1.  Install  the  JA-83M  magnetic  detector,  select  its  reaction  via  the 

internal  DIP  switch  (INS/DEL),  connect  its  battery  up  and  close  the 
cover. 

2.  Install  the  JA-83P  PIR  motion  detector  about  2  to  2.5  meters  above 

the  floor,  select  its  reaction  via  the  relevant  internal  DIP  switch 
(INS/DEL), connect its battery and close the cover. 

3.  Plug the JA-80L siren into a mains power socket. 

 
 

B

A

B

+

B

A

B

reed contact

tamper 

INSTANT

DELAY

 serial number

battery CR123A

1

2

3

4

5

6

7

8

9

1

2

3

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Main board

Transformer

Back-up battery

Mains terminal

Digital bus connector

Tamper switch

LED

Antenna connection

0

1

0

2

C

O

M

0

3

0

4

E

W

IW

P

G

X

P

G

Y

G

N

D

A

B

+

U

RESET

1 2 3 4

ON

OFF

Radio module

Antenna

1

2

V

  

  

2

,4

A

h

 

 

Отзывы: