The JK-84 “Oasis” wireless alarm kit 

2 / 2 

MKE59904  

+

1

2

3

45

6

78

9

1

2

3

tab

strap

 

 

To  observe  EN  50131-2-2  the  battery  in  the  JA-83P  must  be  fixed  with  the 
supplied strap and the tabs must be secured by the supplied screw. 

 

 

4. 

Enrolling more wireless devices 

The system can be extended with more wireless devices (a maximum 

of  50  can  be  enrolled).  To  enroll  another  device,  the  CP  should  be  in 
service mode, if it is not enter 

∗∗∗∗

 0 8080 (while the system is unset). 

1.  On the keypad, key in 1 to enter enrollment mode. 
2.  The  next  vacant  address  is  displayed  (scroll  to  other  addresses 

using the arrow 

& 7 

 if desired). 

3.  Connect  up  the  device’s  battery  to  enroll  the  device  to  the  CP. 

Successful  enrollment  is  confirmed  by  the  A  indicator  lighting.  The 
next vacant address is then displayed. 

o

  The RC-86 key-fob can also be enrolled by pressing and holding 

a pair of its buttons 

+

 (or 

+

). 

4.  Exit enrollment mode by pressing the # key. 

  To enroll the CP to UC-82 or  AC-82 modules, enter 299 while the 

CP is in service mode with the receiving module in enrollment mode. 

5. 

Testing device functionality  

1.  The CP should be in Service mode, if not enter 

∗∗∗∗

 0 8080 

2.  First  trigger  the  device  under  test  (e.g.  a  detector).  The  keypad 

(with  its  flip  cover  open)  then  indicates  triggering  of  the  device  if 
the device is functioning correctly and is enrolled. 

  Motion  detectors  are  best  tested  within  15  minutes  of  closing  their 

covers  as  after  that  they  only  react  to  frequent  movements  once 
every 5 minutes (to restart a device’s test mode, open and close the 
detector housing again). 

6. 

Checking a device’s radio signals 

1.  The CP must have its antenna connected and should be in Service 

mode, if not enter 

∗∗∗∗

 0 8080 

2.  Enter 298, the lowest address with enrolled device will be displayed. 
3.  Trigger  the  device  linked  to  this  address  –  the  keypad  (with  its 

flip  cover  open)  then  shows  the  device’s  signal  strength  in  the 
range ¼ to 4/4 (it should be at least 2/4, if not, relocate the device)   

o

  Motion detectors are best tested within 15 minutes of closing their 

covers as after that they only react to frequent movements once 
every 5 minutes (to restart a device’s test mode, open and close 
the detector housing again). 

o

  To test the JA-81F keypad signal, trigger the connected magnetic 

door sensor or activate the keypad’s tamper sensor. 

o

  To test the JA-80L siren signal, press the siren’s button. 

4.  To select the next enrolled device address use the keys 1 & 7. 
5.  To exit signal measurement mode, press the # key. 

7. 

Programming the system 

1.  The CP should be in Service mode, if not enter 

∗∗∗∗

 0 8080 

2.  Enter the appropriate programming sequences to select the desired 

functions  (a  complete  list  of  them  is  in  the  CP  and  communicator 
manuals). 

 

Function 

Sequence 

Note 

New service code 

5 xxxx 
xxxx 

Factory default: 8080  
xxxx = new code 

Exit delay 

20x 

x = multiples of 10 sec.  
(e.g.  205 = 50 sec)  
Factory default:  30 sec 

Entrance delay 

21x 

x = multiples of 5 sec.  
(e.g.  204 = 20 sec) 
Factory default: 20sec 

Alarm duration 

22x 

x = 1 to 8 means 1 to 8 minutes 
and 9 means 15min. 
Factory default: 4 min 

Time and date entry 

4 hh mm DD MM YY 

 

 

8. 

Editing keypad text strings  

1.  The CP should be in Service mode, if not enter 

∗∗∗∗

 0 8080  

2.  Press and hold the ? key to enter editing mode. 
3.  Keys:  

1 & 7 are for the selection of text strings,  

 

3 & 9 scroll through characters and numbers
4 & 6 move the cursor
2 erases the highlighted character, 
# exits editing mode. 

Editing  text  only  affects  the  text  in  that  particular  keypad.  A  more 
convenient way of text editing is with a PC running Olink software. 

9. 

Finishing off the installation 

1.  Exit  service  mode  via  the  #  key  and  demonstrate  clearly  how  to 

operate the system to the user(s). 

2.  Recommend  the  user  to  change  the  default  master  1234  code  to  a 

new master code. 

 

Entry 

Function 

code / card 

Setting/unsetting (arming and disarming) 

ABC 

Complete arming (all sections) 

Partially setting A (if used) 

Partially setting AB (if used) 

Reading the event memory (4 scrolls backwards) 

Changing the MASTER code/card (e.g. *5 1234 
2789 2789) 

To create a new user code/card (e.g. *6 1234 03 
3344 programs user code number 3, to erase the 
code enter: *6 1234 03 0000) 

7 code/card 

To secretly signal operation (unsetting) under duress 

8 a 

PGX and PGY control (if used) 

0 MASTER 

code 

Maintenance mode (testing, overview of codes, 
bypassing,…) 

Exiting maintenance mode or terminating an 
incomplete entry 

Displays status details (triggered detectors, fault 
causes or the status of PG outputs …..) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 