JA-82K control panel installation manual   

- 19 - 

MKH51102 

 

fig. 18 continues 

Function 

Sequence 

Options 

Factory 

default 

Setting to 

comply with 

EN-50131-1 

Notes 

Service mode only with  
s user (master) code 

697x 

6971 = YES     6970 = NO 

NO YES 

 

Device reactions and section assignment 

(detectors, key fobs, control panel and 
keypad inputs) 

 

A detector’s natural reaction

 

can be INS, DEL or Fire (selectable in the 
detector) 

 

The natural reaction

 of 

Control 

panel & Keypad wired inputs  

is DEL 

Keyfob natural reactions: 

 (or

)= 

SET (arm) , 

 (or

)= UNSET (disarm) 

and both simultaneously = Panic. If a 
reaction from 2 to 8 is selected (see 
opposite), only the key 

 (or

) and 

double buttons 

 + 

 (

+  ) will have 

it. The 

 (

) button has no effect (can still 

be used for controlling UC/AC receivers).

 

 

Assignment to sections

 will only 

have an effect on partial arming or if the 
system is split (except PG output control)   

 

For partial arming, 

a

 

pair of 

keyfob

 buttons assigned to section: 

A has the effect:

 

 (or

)=SET A, 

 

(or

)=SET AB  

B has the effect:

 

 (or

)=SET A, 

 

(or

)=SET AB 

C has the effect:

 

 (or

)=SET ABC, 

 (or

)=UNSET ABC

 

 

In a split system, a keyfob

 

button pair assigned to section: 
A=SET/UNSET A, B =SET/UNSET B, C 
=SET/UNSET ABC  

 

61 nn r 

Code (card) reactions and section 
assignment 

 

A code (card) may have the same kind 

of reaction as devices 

 

Assignment of the code to sections 

is 

useful for split systems only. In a split 
system, a code (card) assigned to C will 
SET/UNSET all ABC sections.

  

62 nn r 

 
nn 

address

 01 to 50  

r = reaction

 

 0 disabled (incl. tamper 
sensor) 
 1 

Natural 

– this means: 

for detectors

=selected by 

DIP switch in the detector, 

for wired inputs

=DELay, 

for Codes 
(cards

)=SET/UNSET 

 2 Panic 
 3 Fire 
 4 24 hours 
 5 Next DELay 
 6 INStant 
 7 SET (arm) 
 8 PG control (s: 1=PGX, 
2=PGY,3=PGX+PGY) 
 9 SET/UNSET (toggle) 

 

 

 

s = section

 1=A, 2=B, 3=C - 

has to be entered even if the 
system is not split and setting 
(arming)has no meaning.  

 

 
 
 
 
 
 
 
 

all 

Natural  

in C 

 
 
 

 

 
 

When the detector is disabled 
(r=0), the tamper sensor is not 
triggered,  
Natural reaction of control panel  
wired inputs  (or IN keypad input) 
is delayed (DEL)

 

Enrollment by keying in production codes 

 60 nn 
xxxxxxx

nn

 = address 01 to 50, 

xxxxxxxx

 = last 8 digits of the 

production code (below the bar code on the device)  

 

Automatic Daily Setting/Unsetting schedule 
(arming/disarming) 

64

nahh

mm

 

n –

 action sequence index (0 to 

9)  

a –

 action: 

 

0=no action 

 1=SET ABC 
 2=UNSET ABC 
 3=SET A 
 4=SET B (if unsplit then AB) 
 5=UNSET A (if unsplit then ABC) 
 6=UNSET B (if unsplit then ABC) 

 hh -

 hours, 

mm - 

minutes 

 

No action 

 

 
The scheduled actions will 
happen every day 

Changing the service code 

5 NC NC 

NC = new code

 (4 digits)  

8080 

 

enter NC twice  

Go to maintenance mode 

292 

switches to 

maintenance

 

mode 

-  

 

Setting the internal clock 

4 hh mm DD MM YY

 

00:00 

1.1.00 

 

 

Editing keypad text 

Text for device names, code names and 
PG output names are stored in each 
individual keypad.  
 

Press and hold the 

?

 key to enter text 

editing (the first character of the first 
address name will start flashing). Then 
use keys: 

 and   to select some text (or an 

address)  

1

 & 

7

  character selection 

(A,B,C,D...8,9,0) 

4

 & 

5

 cursor (to the left & right) 

2

 to erase a character 

# = 

exit editing

 and save changes 

 
Device 

Only capital letters can be entered this way. If 
there are multiple keypads, each must be edited 
individually this way or all of them can be easily  
programmed via OLink software 

 

Содержание JA-82K OASiS

Страница 1: ...JA 82K OASiS Control panel installation manual...

Страница 2: ...6 21 Bypass user approval 9 6 22 Final door detectors 9 6 23 Partial setting arming or system splitting 9 6 24 Automatic summer time daylight saving time 10 6 25 Pulse reaction of tamper sensors 10 6...

Страница 3: ...ring the control panel for installation The control panel can be attached to the wall using 3 screws If the control panel communicates via radio it should not be installed near any large metal objects...

Страница 4: ...input modules By adding the JA 82C module it is possible to extend the amount of inputs to fourteen addresses 01 14 All hard wire inputs behave identically they are double balanced inputs which are ab...

Страница 5: ...p time in case of a power grid failure For the standby consumption of all system devices see fig 8 ATTENTION the backup battery is sold charged avoid shorting out its terminals The average backup batt...

Страница 6: ...and then wait until it is ready for testing 3 The keypad its cover should be flipped open beeps and displays a description of the signal received from the device under test 4 You can test the enrolle...

Страница 7: ...a code or card These PG output functions can also be controlled by signals from keyfobs or detectors see 6 40 Notes The PGX and PGY outputs are not only provided as control panel terminals but the si...

Страница 8: ...r detector gets triggered i e a detector with an instant delayed or next delayed reaction an alarm will not be caused but the control panel will record a so called unconfirmed alarm If any other intru...

Страница 9: ...door is not opened again during this short period the exit delay will terminate and the system will be set immediately The duration of the exit delay therefore depends on the time the final door stay...

Страница 10: ...sed in Service Mode the display turns off after 15 minutes of no use by the installer Factory default setting only 3 minutes of display time 6 28 Tamper alarm if unset According to EU legislation an u...

Страница 11: ...erference was present Factory default setting standard control panel sensitivity 6 37 Access by code plus card This feature increases security against unauthorised setting unsetting arming disarming 6...

Страница 12: ...e buttons or The button has no effect can still be used for controlling UC AC receivers Factory default setting All addresses from 01 to 50 have a natural reaction r 1 and are assigned to section C s...

Страница 13: ...called internal text such as service maintenance mode etc and this text can also be edited via OLink software by selecting Central on the menu and then Text synchronization Comparison or F11 After ed...

Страница 14: ...still set he will not need to unset the whole system before leaving the house and setting the whole system The route used by the user to leave the house must be covered by delayed or next delayed det...

Страница 15: ...he installation in a very professional and conscientious manner and always tidy up the site afterwards It is very important to teach the end user how to use and test the system and to check his level...

Страница 16: ...e after 10 events Fault signal or message after 1 event Security grade 2 according to EN 50131 1 EN 50131 6 and EN 50131 5 3 Environmental class II indoor general 10 to 40 C compliant with EN 50131 1...

Страница 17: ...ay A PG on 3 entrance delay B PG on 4 A set X on B set Y on 5 A panic X on B panic Y on 6 Fire X on AC dropout Y on 7 PG on off by 80 81for PGX and 90 91 for PGY 8 Single 2 s pulse keys 8 X 9 Y Enable...

Страница 18: ...ber of triggered tamper sensors 681x 6811 ignore permanently triggered tamper sensors i e only react to an increase in the number of triggered tamper sensors 6810 react with a tamper alarm to all trig...

Страница 19: ...switch in the detector for wired inputs DELay for Codes cards SET UNSET 2 Panic 3 Fire 4 24 hours 5 Next DELay 6 INStant 7 SET arm 8 PG control s 1 PGX 2 PGY 3 PGX PGY 9 SET UNSET toggle s section 1...

Страница 20: ...To make handing over the system to the end user easier we recommend programming the system card provided with the control panel to the master code Example 5 1234 and then presenting the card to the ke...

Страница 21: ...Notes...

Страница 22: ......

Отзывы: