MNY51104 

Erasing tel. 
numbers 
authorised for 
relay control 

EDX, x..x, x..x  

For relay 

Y

 enter 

EDY, x..x

 = tel. 

number (up to 100 number can be 
erased).  

Example

: erase telephone number 

for controlled relay X by dialling in: 
EDX, 777123457

 

None 

SMS reporting initiated by triggering of the A – D inputs 

Input activation 
text 

ATA, xx..x 

For 

input enter

 ATB 

etc., 

xxx..x 

text, up to 30 characters 

 

To erase text: 

ATA , ,

 (no text = no 

activation reporting) 

Example:

 

ATC, heating on

 

A1,  
B1,  
C1,  

D1 

Input 
deactivation 
text 

DTA, xx..x 

For 

input enter

 DTB 

etc., 

xxx..x 

text, up to 30 characters 

 

To erase text enter: 

DTA , ,

 (no text 

= no deactivation reporting) 

Example:

 

DTC, heating off

  

A0,  
B0,  
C0,  

D0 

Telephone 
numbers for 
input reports 

TNA, x..x, x..x 

For 

input enter 

TNB 

etc., 

x..x

 = 

tel. number, up to 100 for each 
input. All previously stored numbers 
are erased.  To erase all numbers 
for input enter: 

TNA,.,

 

Example:

 TND, 777123456, 

608123456, 775145522 sets the 
GD-04K to report input D events to 
2 numbers

 

None 

Input – event 
calls 

DNA, n 

For 

B

 input enter 

DNB

 etc., 

n

 = 1 

(ON), 0 (OFF). If set to ON, every 
SMS report is followed by a call.

 

Example

DND, 1

 

 

Disabled 

Other functions

 

New 
programming 
password 

NPC, xx…x 

xx…x

 = new programming 

password, from 2 to up to 30 
characters 

Example:

 

NPC, MARTIN27 

PC 

SMS to get GD-
04K status –
 text change 

STS, xx..x 

xxx..x 

= text, up to 30 characters* 

Example:

 

STS, HOW ARE YOU 

STATUS 

Service 
telephone 
numbers 

STN, x..x, x..x 

xxx..x 

= tel. number, Up to 2 

numbers can be set, previously set 
numbers are erased. Service 
numbers are used to report faults: 

POWER FAIL

 / 

POWER 

RECOVERY 
LINE OK

 (GSM signal recovery) 

Other events – see 

Optional 

functions

 

To erase the service number enter: 

STN,.,

 

åiGQp

 

 

GD-04K - 

-  MNY51104 

3.  Send the SMS command: 

STATUS

 from your cell phone to the SIM card inserted into 

the GSM communicator. 

4. 

The communicator answers by SMS 

like this: 

STATUS: A0,B0,C0,D0,X0,Y0, 

GSM:80%, Vcc:12.1 V 

(which means that all inputs and both relay outputs are 

deactivated/switched off, the GSM signal strength is 80% and the power voltage is 
12.1 V). The response speed depends on current GSM network traffic. With no 
response, check if the text “STATUS” has been written correctly and sent to the correct 
telephone number. 

6. Settings 

 

6.1.  Local setting using PC 

The most comfortable way of settings the GD-04K is by computer and 

GD-Link 2.0.0

 (or 

higher) software which allows saving the settings for the later use. Programming SW is free 
for download from 

www.jablotron.com

. The software requires a Windows XP operating 

system or newer.  

When connected to the Internet, GD-Link checks whether a new version of the GD-Link 

is available. In such case an update is offered immediately. The current FW which is part of 
the GD-Link package is also downloaded and once the GD-04K is connected to the PC 
automatic upgrade is offered. A FW upgrade can be performed also manually by clicking 
on the option 

Device / Firmware update from the file

Connection procedure: 

  Connect a PC using the supplied USB cable with the miniUSB connector (2) on the 

communicator´s main board. 

  Start the GD-Link 2.0.0 SW or higher. 

  According to the settings, the required action in the initial window can be chosen or the 

communicator is connected automatically. 

  If the setting is modified offline without connected GD-04K, then to go online press the 

button “Online” on the upper toolbar when the unit is connected. 

 

Figure 2

 

Содержание GD-04K

Страница 1: ...settings If pulse mode is selected then based on activation command the output will be switched for interval between 1 s to 10 hrs Dialling in Both relays X and Y can be controlled by dialling in fro...

Страница 2: ...Output relay fuses 9 Input output and power terminals Terminal descriptions Low voltage terminals 12 V Terminal for 12 V DC connection from included adapter or another external power supply which pro...

Страница 3: ...re galvanically separated from the communicator circuits complying with 4kV safety isolation requirements 3 Installation and initial setup 1 Select an appropriate place for communicator installation c...

Страница 4: ...backup battery is charged 5 Initial powering up 1 Turn the power on the red LED starts flashing to indicate logging of the module on to the GSM network if it doesn t check the power supply proper con...

Страница 5: ...r events see Optional functions To erase the service number enter STN iGQp GD 04K 5 MNY51104 3 Send the SMS command STATUS from your cell phone to the SIM card inserted into the GSM communicator 4 The...

Страница 6: ...llows all parameters to be set as if you are connected locally using a USB cable Figure 3 GD 04K 11 MNY51104 11 Table 1 SMS programming instructions overview A programming SMS always has to begin with...

Страница 7: ...ngs in your computer for future use Save When the communicator receives new setting then a factory RESET is performed and the setting is uploaded All programming options which are not filled in will b...

Страница 8: ...When a pre set limit has been reached the telephone number can not be used to control more Control by dialling in can only be realized by phone numbers with enabled caller ID visibility telephone numb...

Отзывы: