Car Alarm CA-10 REX
2/2
MEM51107
One siren chirp* confirms arming. If four fast siren chirps are generated, it
indicates that an input is activated (a door is not closed properly).
DISARMING
- press either button (
or
), and the siren should chirp
twice*. After opening a door the dome light will come on until you switch
the ignition key on. If you do not enter the car within 1 min. after disarm-
ing, the car alarm will rearm automatically*.
ALARM
is indicated by siren for 30 sec. It will then return to the armed
mode. Sound can be stopped by either button (
or
) but the car alarm
will remain armed. To disarm it, press either button once more.
ALARM MEMORY
- press button
while the ignition key is on to learn
the cause of the last alarm. The LED indicates the cause by the number
of flashes (2=ignition, 3=door, 5=AL input, 6=current detector,
7=vibrations). Use button
the same way for the second from the last
alarm indication.
PANIC
(car finding) signal - can be triggered any time if the
&
but-
tons are pressed simultaneously.
EMERGENCY DISARMING
* - If you lost your remote control, open the car
(this triggers the alarm), switch on ignition and press the VALET button.
REMOTE CONTROL BATTERY
- if the remote control’s working distance
continuously decreases, then replace the remote control battery (after
releasing the screw on the rear side of its housing). A suitable replace-
ment battery is L1016 (6VDC). A quality battery’s approximate life time is
one year.
*/ marked features are selectable in setting mode
Remarks about the CA-10 features:
•
all trigger inputs starts to work 8 sec. after arming. The current consumption
detector is active 10 minutes after arming. This enables the cooling system
fan to function.
•
if any trigger input is active when arming (not properly closed door etc.), the
CA-10 will be armed without this input. The siren will indicate such arming
with four fast beeps.
•
the vibration detector can only trigger 3 alarms as a maximum during each
arming period.
•
number of LED flashes after ignition key turning on indicates how many
remote controls are available for the car alarm.
•
if central locking is connected to the car alarm (with CR-11A module), arming
will lock the doors and disarming will unlock them
•
if the car alarm has an immobilization function (with CR-11A module), the
immobilization will be switched off only when the car alarm is disarmed and
the ignition key is turned on
Specifications
voltage
12VDC (8 - 15VDC)
stand by consumption
max. 20 mA
remote control
radio signal, hopping code, ANTISCAN
working temperature
-40 to +125°C
siren loudness
120dB/1m
alarm memory
possibility to indicate last 2 events
built in drop voltage detector
disabled for 10 min. after arming
built in vibration detector
selectable reaction (alarm or warning)
inputs/outputs:
1x door switches input
(also courtesy light output) - negative trigger
1x input AL
selectable logic for NC or NO detector
1x ignition input
+12V
1x VALET push button
setting and executive override
1x digital bus output AUX
for CR-11A extending modules
The CA-10 complies with IEC 839-10-1, EEC No. 97
Can be operated according to ERC REC 70-03
Hereby, Jablotron Ltd., declares that this CA-10 is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz
, section Technical support.
Extension of CA-10 for more functions
There is a blank position on the CA-10 main unit connector marked with
an pink mark. You can insert the pink wire (included in the set) here. This wire
is a digital bus which provides data for a CR-11A extending module.
Four CR-11A modules, as a maximum, can be connected to the CA-10
(see diagram above). The CR-11A module has two built in relays, each with
over switching contact of 15Amp. Functions of the relays are selectable with a
switch inside each CR-11A module (8 options - see the table bellow).By using
the CR-11A modules, requested functions can be added to the car alarm
(central locking control, immobilization, additional siren, wireless pager, pow-
ered windows remote control etc.). This way the CA-10 car alarm can be
tailored according to your needs.
Wiring of each CR-11A module is simple, just +12V, ground and the pink
wire (data from CA-10). There are also relay contact outputs (6 pins). You will
find more details regarding CR-11A in its manual.
Example of CR-11A use for central locking actuators control
Selectable functions of CR-11A output relays
mode #
relay no. 1 function
relay no. 2 function
1
1sec. pulse
after simultaneous
pressing of
&
buttons on
the remote control,
when armed
1sec. pulse
after simultaneous
pressing of
&
buttons on
the remote control,
when disarmed
2
relay
will change status
after
simultaneous
pressing of
&
,
on RC,
when armed /*
relay
will change status
after
simultaneous
pressing of
&
, on RC,
when disarmed
/*
3
left blinker
signals
(arming, disarming, alarm)
right blinker
signals
(arming, disarming, alarm)
4
lock
(pulse duration selectable in
CA-10 setting mode)
unlock
(pulse duration selectable in
CA-10 setting mode)
5
immobilization
(switched ON when
disarmed and key is ON)
alarm
(switched ON during alarm
condition)
6
immobilization
(switched ON when
disarmed and key is ON)
arming signals
(1 pulse = arming,
2 pulses = disarming)
7
courtesy light control
follows
door sw 1 min.
arming signals
(1 pulse = arming,
2 pulses = disarming)
8
immobilization
(switched ON when
disarmed and key is ON)
courtesy light control
follows
door sw 1 min.
9
double locking impulse
– during
arming relay will be switched ON
for 0.3s, then switched OFF for 1s
and switched ON for 0.3 again
double unlocking impulse
–
during disarming relay will
switched ON for 0.3s, then
switched OFF for 1s and switched
ON for 0.3 again
10
Second locking impulse
–
1s
after preset locking car alarm
impulse, relay will be switched
ON for 0.3s
Second unlocking impulse
– 1s
after preset unlocking car alarm
impulse, relay will be switched
ON for 0.3s
11
controlling of relay via SMS
–
only for CA-120x, see CA-120x
manual for more details
controlling of relay via SMS
–
only for CA-120x, see CA-120x
manual for more details
/* relay will also switch off 15 minutes after arming or disarming
Note: Although this product does not contain any harmful materials
we suggest you to return the product to the dealer or directly to the