7.   TECHNICAL SPECIFICATIONS

PARAMETER

JA-103K

JA-107K 

Control panel power supply

~ 110–230 V / 50–60 Hz,  
max. 0.28 A with fuse F1.6 A/250 V 
Protection class II

~ 110–230 V / 50–60 Hz, 
max. 0.85 A with fuse F1.6 A/250 V 
Protection class II

Back-up battery 

12 V; 2.6 Ah (lead gel)

12 V; 7 to 18 Ah (lead gel)

Maximum battery charging time

72 h

BUS voltage (red - black)

12,0 až 13,8V

Maximum continuous current 
consumption from the control 
panel

1000 mA

2000 mA permanent 
3000 mA for 60 minutes 
(max. 2000 mA for one BUS)

Max. continuous current con-
sumption for back-up 12 hours 

Without GSM com-
municator

LAN – OFF
115 mA
LAN – ON
88 mA

Valid for 18 Ah back-up battery

Without GSM  
communicator

LAN – OFF
1135 mA 
LAN – ON
1107 mA 

With GSM commu-
nicator

LAN – OFF
80 mA
LAN – ON
53 mA

With GSM  
communicator

LAN – OFF
1100 mA 
LAN – ON
1072 mA

Maximum number of devices

50

230

LAN communicator

ETHERNET INTERFACE, 10/100BASE-T

Dimensions

268 x 225 x 83 mm

357 x 297 x 105 mm

Weight with/without AKU

1844 g/970 g

7027 g/1809 g

Reaction to invalid code entry

Alarm after 10 wrong code entries

Event memory

Approx. 7 million latest events, including date and time

Power supply unit

Type A (according to EN 50131-6)

GSM communicator

850 / 900 / 1800 / 1900 MHz 

GSM communicator 3G

850 / 900 / 1800 / 1900 / 2100 MHz

Classification

Security grade 2 / Environmental class II (according to EN 50131-1)

Operational environment

Indoor general

Operational temperature range

-10 °C to +40 °C

Average operational humidity

75 % RH, non-condensing

Complies with

EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1,  
EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581

Radio operating frequency (with 
the JA 11xR module)

868.1 MHz, JABLOTRON protocol

Radio emissions 

ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)

EMC

EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7

Safety conformity

EN 62368-1+A11

Operational conditions

ERC REC 70-03

Certification body

Trezor Test s.r.o. (no. 3025)

Caller identification (CLIP)

ETSI EN 300 089

JABLOTRON ALARMS a.s. hereby declares that the control panels JA-103K a JA-107K are in a compliance with the 
relevant European Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU, 
when used as intended. The original of the conformity assessment can be found www.jablotron.com – Downloads section.

Note: Although these products do not contain any harmful materials we suggest you return these products to the dealer  
or directly to the producer after use. 

Содержание 100+

Страница 1: ...User manual...

Страница 2: ...COMPUTER J LINK 18 2 3 REMOTE OPERATING 18 2 3 1 OPERATING THE SYSTEM USING THE MyJABLOTRON SMARTPHONE APP 19 2 3 2 OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE 19 2 3 3 OPERATING THE SYSTE...

Страница 3: ...5 1 USING THE LCD KEYPAD 23 5 2 USING THE J LINK SOFTWARE AND A COMPUTER 23 5 3 LOGGING INTO MyJABLOTRON WEB SMARTPHONE 23 6 PERIODICAL MAINTENANCE 24 7 TECHNICAL SPECIFICATIONS 25 8 GLOSSARY OF TERMS...

Страница 4: ...ed alarm stop sirens from sounding just by authorization in any part of the system depending on their access rights However that does not automatically unset the system unless the system s default set...

Страница 5: ...is allowed only to set a designated section and is allowed to control ON OFF PG outputs which require authorization Users with this level of authorization are not allowed to change their code and are...

Страница 6: ...s are clearly labelled and coloured using traffic light logic so that each segment status is distinctly indicated A segment can also be used to indicate a status e g opened garage door or to control v...

Страница 7: ...by entering a code or the contactless method RFID card tag or a combination of both for higher security Keypad with an LCD display and a card reader the user can control the system using segments and...

Страница 8: ...isplay the J Link software or MyJABLOTRON app If the Code with a prefix parameter is enabled the users can be allowed to change their code If the Code with a prefix parameter is disabled the codes can...

Страница 9: ...and according to the internal settings Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control p...

Страница 10: ...Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section where the entrance delay has been triggered Consult the installation wit...

Страница 11: ...ssed a second time it flashes red If the system is partially set indicated by a continuous yellow light the entire system can be fully set by authorization and pressing the yellow button Once the butt...

Страница 12: ...in menu from the keypad with an LCD display Cancel warning indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 5013...

Страница 13: ...EEN Unset a YELLOW Partially Unset a RED Set Authorization can be done by entering an access code on the keypad or using an RFID card tag assigned to a particular user Each user can have one code and...

Страница 14: ...s Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control panel configuration Displays a list of...

Страница 15: ...ay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator flashing yellow reported to the ARC and indicated by an external siren applies to the sec...

Страница 16: ...when somebody moves inside the section 1 When you enter the building triggering a detector with a Delayed zone reaction the system starts indicating an entrance delay with a continuous tone the system...

Страница 17: ...function button rapidly flashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly flashing red function button indicates the alarm...

Страница 18: ...ns The closed lock icon sets programmed sections the opened lock icon unsets them Correct command execution is confirmed by an LED light unsetting green setting red A communication fault out of the co...

Страница 19: ...then it is possible to set unset the system in the J Link software using an on screen virtual keypad click on Keypad in the main menu WARNING When the system is controlled via PC it doesn t check for...

Страница 20: ...s and Gallery The bottom of the home page has an overview of the most recent system events MyJABLOTRON offers free notifications SMS e mail or push notifications for selected system section events pro...

Страница 21: ...curity system a 15 digit code and the telephone number of its SIM card is required to connect to the system remotely the first time Remote access is initiated by clicking on Internet in the main menu...

Страница 22: ...code or card tag will no longer be accepted by the system The users will also not receive any SMS alerts or voice reports to their phone Only the system administrator or service technician can block...

Страница 23: ...t to flash by pressing Enter Then the RFID card tag must be placed on to the reader or the serial number must be manually entered After confirming by pressing Enter again the RFID card tag is added To...

Страница 24: ...ol panel Each entry includes the date time start and end and source cause origin of the event The different ways of browsing through the system s event history 5 1 USING THE LCD KEYPAD Accessing the e...

Страница 25: ...ted with a selection of sections where the maintenance is needed In the maintenance mode no alarms will be triggered in the selected sections including opening or removing the detectors from the insta...

Страница 26: ...ply unit Type A according to EN 50131 6 GSM communicator 850 900 1800 1900 MHz GSM communicator 3G 850 900 1800 1900 2100 MHz Classification Security grade 2 Environmental class II according to EN 501...

Страница 27: ...ly functioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Out...

Страница 28: ...27 9 NOTES...

Страница 29: ...28 9 NOTES For questions and further information contact your installer MMD55300...

Страница 30: ...M ENJA100 USER www jablotron com...

Отзывы: