9
2.1.2.1 ALARM SETTING
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react in one
of the following ways (based on the system configuration):
a
Detectors will guard automatically after they switch to a standby mode (default setting).
a
The system will optically indicate triggered detectors with a segment flashing red for 8 seconds
and the system will set automatically once this period has expired.
a
Setting the section with triggered detectors is also possible by pressing the segment button on the right
side repeatedly. This way a user confirms an intention to set the section with a triggered detector
(e.g. an opened window). Otherwise the section with the triggered detector will not be set.
a
A triggered detector will prevent the section from being set. This status is optically indicated
by a flashing red segment button. The detector preventing setting will be shown in the menu
on the keypad’s LCD display.
An unsuccessful setting is indicated by the indication button flashing yellow (“Unsuccessful setting”
parameter must be enabled).
Consult the installation with a service technician in order to program the desired behaviour of the system.
2.1.2.2 ALARM UNSETTING
Note:
If the “Unset section by authorization only during entrance delay” parameter is enabled, then mere
authorization will unset such section where the entrance delay has been triggered.
Consult the installation with a service technician in order to program the desired behaviour of the system.
1. Authorize using the keypad.
Sections which can be controlled
are lit up and the backlit indication
button will start flashing green.
2. Press the right button
(the one which isn’t lit up) to set
a particular section. It is possible
to set more sections subsequently.
The delay between sections
selection must not be longer than
2 seconds.
3. The command is executed
and the keypad acoustically indica-
tes the exit delay. The section is set
now, only the detectors with
a “Delayed Zone” reaction provide
time to leave the guarded area
during the exit delay. The segment
button of the set section turns red.
1. When you enter the building
(triggering a detector with
a “Delayed zone” reaction),
the system starts indicating entran-
ce delay with a continuous tone
and segment button of the section
in which the delayed entrance has
been triggered flashing green.
Authorize yourself using the
keypad
– the green indication light
of the authorization panel starts
flashing.
2. Press the left segment button
of the section you want to unset.
3. The command is executed
and the segment buttons turn
green to indicate unset sections.