2.1.2.1   ALARM SETTING 

While setting the alarm, if any detector is triggered (e.g. an open window) the system will react in one  

of the following ways (based on the system configuration): 

a

  Detectors will guard automatically after they switch to a standby mode (default setting).

a

  The system will optically indicate triggered detectors with a segment flashing red for 8 seconds  

     and the system will set automatically once this period has expired.

a

  Setting the section with triggered detectors is also possible by pressing the segment button on the right  

     side repeatedly. This way a user confirms an intention to set the section with a triggered detector  
     (e.g. an opened window). Otherwise the section with the triggered detector will not be set.

a

  A triggered detector will prevent the section from being set. This status is optically indicated  

     by a flashing red segment button. The detector preventing setting will be shown in the menu  
     on the keypad’s LCD display.

An unsuccessful setting is indicated by the indication button flashing yellow (“Unsuccessful setting” 

parameter must be enabled).

Consult the installation with a service technician in order to program the desired behaviour of the system.

2.1.2.2   ALARM UNSETTING

Note:

 

If the “Unset section by authorization only during entrance delay” parameter is enabled, then mere 

authorization will unset such section where the entrance delay has been triggered.

Consult the installation with a service technician in order to program the desired behaviour of the system.

1.  Authorize using the keypad. 

Sections which can be controlled 
are lit up and the backlit indication 
button will start flashing green.

2.  Press the right button

(the one which isn’t lit up) to set  
a particular section. It is possible 
to set more sections subsequently. 
The delay between sections 
selection must not be longer than 
2 seconds.

3.  The command is executed

and the keypad acoustically indica-
tes the exit delay. The section is set 
now, only the detectors with  
a “Delayed Zone” reaction provide 
time to leave the guarded area 
during the exit delay. The segment 
button of the set section turns red.

1.  When you enter the building

 

(triggering a detector with  
a “Delayed zone” reaction),  
the system starts indicating entran-
ce delay with a continuous tone 
and segment button of the section 
in which the delayed entrance has 
been triggered flashing green.

Authorize yourself using the 

keypad

 – the green indication light 

of the authorization panel starts 
flashing.

2.  Press the left segment button 

of the section you want to unset.

3.  The command is executed 

and the segment buttons turn 
green to indicate unset sections.

2.   OPERATING THE JABLOTRON 100+ SYSTEM

Содержание 100+

Страница 1: ...User manual...

Страница 2: ...COMPUTER J LINK 18 2 3 REMOTE OPERATING 18 2 3 1 OPERATING THE SYSTEM USING THE MyJABLOTRON SMARTPHONE APP 19 2 3 2 OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE 19 2 3 3 OPERATING THE SYSTE...

Страница 3: ...5 1 USING THE LCD KEYPAD 23 5 2 USING THE J LINK SOFTWARE AND A COMPUTER 23 5 3 LOGGING INTO MyJABLOTRON WEB SMARTPHONE 23 6 PERIODICAL MAINTENANCE 24 7 TECHNICAL SPECIFICATIONS 25 8 GLOSSARY OF TERMS...

Страница 4: ...ed alarm stop sirens from sounding just by authorization in any part of the system depending on their access rights However that does not automatically unset the system unless the system s default set...

Страница 5: ...is allowed only to set a designated section and is allowed to control ON OFF PG outputs which require authorization Users with this level of authorization are not allowed to change their code and are...

Страница 6: ...s are clearly labelled and coloured using traffic light logic so that each segment status is distinctly indicated A segment can also be used to indicate a status e g opened garage door or to control v...

Страница 7: ...by entering a code or the contactless method RFID card tag or a combination of both for higher security Keypad with an LCD display and a card reader the user can control the system using segments and...

Страница 8: ...isplay the J Link software or MyJABLOTRON app If the Code with a prefix parameter is enabled the users can be allowed to change their code If the Code with a prefix parameter is disabled the codes can...

Страница 9: ...and according to the internal settings Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control p...

Страница 10: ...Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section where the entrance delay has been triggered Consult the installation wit...

Страница 11: ...ssed a second time it flashes red If the system is partially set indicated by a continuous yellow light the entire system can be fully set by authorization and pressing the yellow button Once the butt...

Страница 12: ...in menu from the keypad with an LCD display Cancel warning indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 5013...

Страница 13: ...EEN Unset a YELLOW Partially Unset a RED Set Authorization can be done by entering an access code on the keypad or using an RFID card tag assigned to a particular user Each user can have one code and...

Страница 14: ...s Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control panel configuration Displays a list of...

Страница 15: ...ay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator flashing yellow reported to the ARC and indicated by an external siren applies to the sec...

Страница 16: ...when somebody moves inside the section 1 When you enter the building triggering a detector with a Delayed zone reaction the system starts indicating an entrance delay with a continuous tone the system...

Страница 17: ...function button rapidly flashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly flashing red function button indicates the alarm...

Страница 18: ...ns The closed lock icon sets programmed sections the opened lock icon unsets them Correct command execution is confirmed by an LED light unsetting green setting red A communication fault out of the co...

Страница 19: ...then it is possible to set unset the system in the J Link software using an on screen virtual keypad click on Keypad in the main menu WARNING When the system is controlled via PC it doesn t check for...

Страница 20: ...s and Gallery The bottom of the home page has an overview of the most recent system events MyJABLOTRON offers free notifications SMS e mail or push notifications for selected system section events pro...

Страница 21: ...curity system a 15 digit code and the telephone number of its SIM card is required to connect to the system remotely the first time Remote access is initiated by clicking on Internet in the main menu...

Страница 22: ...code or card tag will no longer be accepted by the system The users will also not receive any SMS alerts or voice reports to their phone Only the system administrator or service technician can block...

Страница 23: ...t to flash by pressing Enter Then the RFID card tag must be placed on to the reader or the serial number must be manually entered After confirming by pressing Enter again the RFID card tag is added To...

Страница 24: ...ol panel Each entry includes the date time start and end and source cause origin of the event The different ways of browsing through the system s event history 5 1 USING THE LCD KEYPAD Accessing the e...

Страница 25: ...ted with a selection of sections where the maintenance is needed In the maintenance mode no alarms will be triggered in the selected sections including opening or removing the detectors from the insta...

Страница 26: ...ply unit Type A according to EN 50131 6 GSM communicator 850 900 1800 1900 MHz GSM communicator 3G 850 900 1800 1900 2100 MHz Classification Security grade 2 Environmental class II according to EN 501...

Страница 27: ...ly functioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Out...

Страница 28: ...27 9 NOTES...

Страница 29: ...28 9 NOTES For questions and further information contact your installer MMD55300...

Страница 30: ...M ENJA100 USER www jablotron com...

Отзывы: