Wireless outdoor siren JA-80A 

JA-80A is completely wire-free siren in a solid housing. It signalizes intruder alarm acoustically and 
by red LED lights. The length of sounding in case of an alarm event can be set between 0 seconds 
and 4 minutes (go to JabloTool, Peripherals, then click on the enrolled JA-80A). If the internal siren 
JA-80L is also enrolled, it sounds alarm for the same period of time.  

The siren is battery powered. Maximum battery lifetime is 3 years. 

Opening the cover signalizes Alarm (unauthorized manipulation) to the camera. 

LED lights keep flashing for 30 minutes after Alarm. 

 

4.1  Enrolling sirens 

Siren should be at least 2 meters away from the camera during enrolment. 

4.1.1 

Enrolling JA-80L 

1.  Reset the siren if it has been previously enrolled in another device 

 

Unplug the siren from the mains socket.  

 

Press and hold the siren button and plug the siren in the mains socket.  

 

Keep the button pressed until two beeps are heard which confirms a reset.  

2.  The indicator keeps flashing after reset (device is in enrolment mode). 
3.  Send the enrollment signal from the camera.  

 

Go to JabloTool via internet, tab Peripherals and click on Add new device, or  

 

Go to JabloTool via USB, click on the icon of camera in the list of on-line devices, go to 
Configuration, External devices and click on Add new device, or 

Note: Do not use remote control to switch the camera in the Enrol mode when siren is in Enroll 
mode because the remote control would then enroll into the siren.

 

4.1.2 

Enrolling JA-80A 

1.  Reset the siren by unplugging its battery. Do the reset if another device has been previously enrolled in the 

siren.  

2.  Switch the camera into enroll mode. The options are described in the chapter 1.2. 
3.  Insert battery into the siren. 

The siren stops flashing after it is enrolled. 

 

S

MART SOCKET AND RELAY MODULES 

 

Relay modules make or disconnect electrical contact to the commands by the camera. Relays may have the shape 
of AC power socket that can be directly plugged into the AC 230V mains or boxes to which wires of electric circuit 
are attached. 

The relays are powered by the mains AC 230V (relays AC-82 and AC-83) or by 12V DC (relays UC-82). 

 

5.1  Using smart socket and relay modules 

Camera EYE-02 is equipped with two virtual switches. These switches work as wirelessly sent commands to relays 
to make or disconnect their contact. The switches can be remotely controlled in JabloTool via internet or via USB 
cable. They can also be controlled by SMS commands. 

When the peripherals are turned ON by the camera they make contact and appliances powered via these 
peripherals are turned ON. When they are turned OFF they disconnect contact and appliances are turned OFF. 
Relays can also be set to inverse mode - they disconnect the contact when they are turned ON and vice versa. 

 

Содержание EYE-02

Страница 1: ...External document File name EYE 02 Wireless peripherals 1 12 Wireless peripherals EYE 02 GSM Security Camera Application note...

Страница 2: ...d with the camera at the same time Operating range of peripherals is 100m in free space Wireless buttons detectors and sirens are powered by batteries with typical lifetime of at least 2 years Exact b...

Страница 3: ...to your camera via www jablotool com o Go to tab Peripherals o Click on Add new device 3 Using JabloTool via USB cable o Click on the icon of camera in the list of on line devices o Go to Configurati...

Страница 4: ...doorbell button RC 89 Pressing the button generates Panic alarm even when EYE 02 is in SLEEP mode Example of use The camera is focusing on entrance area in a building Pressing the doorbell button wak...

Страница 5: ...the MW detector is activated and confirms activation of the PIR detector After the confirmation the detector reports Alarm to the camera The detector is enrolled as one peripheral into the camera Wire...

Страница 6: ...e Detector can be enrolled into wireless internal siren JA 80L that will signalize with melody when windows or doors are open Picture 4 EYE 02 camera used with Magnetic door window opening detector JA...

Страница 7: ...R JA 80M JA 80P JA 80PB JA 80S JA 80W JA 81M JA 82M JA 82SH JA 85B JA 85P JA 86P JA 88P Plug the detector JA 80G into the mains Detectors should be at least 1 meter away from the camera during enrolme...

Страница 8: ...evices go to Configuration External devices and click on Add new device or Note Do not use remote control to switch the camera in the Enrol mode when siren is in Enroll mode because the remote control...

Страница 9: ...the relay OFF Camera switches can be configured to several modes SMS ON OFF Switch will turn ON or OFF after pressing a button in JabloTool or after sending an SMS command Example of use Turning ON or...

Страница 10: ...mera it should listen to That is why the camera needs to be enrolled into the relay 5 2 1 Enrolling AC 88 1 First reset the socket You can skip this step if no other device is enrolled there Unplug th...

Страница 11: ...er than set temperature the thermostat sends switches the relay ON The relay makes contact and the heating turns ON Camera can be enrolled into relay where thermostat is enrolled Camera then works as...

Страница 12: ...6 1 1 Enrolling thermostats into EYE 02 camera 1 Switch the camera into Enroll mode it is described in chapter 1 2 2 Insert battery into the thermostat TP 82 or TP 83 6 1 2 Enrolling thermostats and...