warnIngS and error meSSageS
This charger incorporates a variety of functions for protection, these monitor the system to verify
processes and the state of the electronics. In case of an error the screen will display the cause of
error and emit an audible sound.
The output is connected to a battery with incorrect
polarity
This will be displayed if the unit detects a break in the circuit
between the battery and output or if the battery is voluntarily
disconnected during the charge process.
There was a short circuit at OUTPUT. Check the charging
leads.
CONNECTION
BREAK
SHORT ERR
REVERSE
POLARITY
The voltage of the input power supply is below the minimum
of 12V
The voltage of the battery pack to be charged has been
selected incorrectly. Verify the voltage of the battery pack.
The voltage of one of the cells in a Lithium battery pack has
risen above the maximum voltage. Check the voltage of the
cells individually.
There is a bad connection at the individual connector. Check
the connector and cables carefully.
The processor cannot continue to control the charge current
for some reason. Seek professional advice.
The charger has malfunctioned for some reason. Seek
professional advice.
The processor detects that the battery has dropped below the
minimum voltage during the charge process. Check the cell
count of the battery pack.
The processor detects that the battery has risen above the
maximum voltage during the charge process. Check the cell
count of the battery pack.
The voltage of one of the cells in a Li-poly battery pack has
dropped below the minimum voltage. Check the voltage of
the cells individually.
INPUT VOL ERR
VOL SELECT
ERR
BREAKDOWN
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOL
CEL LOW VOL
BATTERY VOL
CEL HIGH VOL
BATTERY VOL
CELL CONNECT
CONTROL
FAILURE