gEL CELL (PB, LEaD aCID) DISChargE PrOgraM
The following program is only suitable for discharging Gel cell (Pb, Lead-Acid) batteries
with nominal voltage from 2V-20V. Do not try to discharge any other type of battery
using this program.
how to discharge:
1. 1. Select “PROGRAM SELECT Pb BATT” from the main menu then scroll to “Pb DISCHARGE” using
the “INC” or “DEC” buttons and press the “Start/Enter” button to select. The display should look
similar to this:
The discharge current is displayed in the lower left.
The final voltage is displayed in the lower right.
The discharge current ranges from 0.1 to 1A. The voltage should match the voltage of the battery
to be discharged.
2. If you need to alter the current or the voltage press the “Start/Enter” button to make it blink then
change the value with “DEC” or “INC” button. The value will be stored by pressing the “Start/
Enter” button.
3. Once the settings are correct press and hold the “Start/Enter” button to begin the discharge
process. The display will now show similar to the following:
4. To change the discharge current during the process press the “Start/Enter” button once.
5. The charger will emit a sound to inform you when the process is complete. To stop the process
early press the “Batt type/Stop” button.
Pb DISCHARGE
4.0A 12.0V(6P)
Pb-6 4.0A 12.59V
DSC 022:45 00682
Battery type
Current
Battery voltage
Elapsed time
Capacity