background image

 

PR_I017/2023-01-23-EN

 

 

31

 

Things not to burn  

"Never  use  gasoline,  gasoline-type  lantern  fuel,  kerosene, 
charcoal lighter fluid, or similar liquids to start or 'freshen up' a 
fire  in  this  heater.    Keep  all  such  liquids  well  away  from  the 
heater while it is in use." 
 

 

Garbage;  

 

Lawn clippings or yard waste;  

 

Materials containing rubber, including tires;  

 

Materials containing plastic;  

 

Waste  containing  petroleum  products,  paints  or  paint 
thinners, or asphalt products;  

 

Materials containing asbestos; 

 

Construction or demolition debris;  

 

Railroad ties or pressure-treated wood; 

 

Manure or animal remains; 

 

Salt  water  driftwood  or  other  previously  salt  water 
saturated materials; 

 

Unseasoned wood;  

 

Paper products, cardboard, plywood, or particleboard.  

The prohibition against burning these materials does not prohibit 
the use of fire starters made from paper, cardboard, saw dust, 
wax and similar substances for the purpose of starting a fire in 
an affected wood heater. Burning these materials may result in 
release of toxic fumes or render the heater ineffective and cause 
smoke. 

 

Wood storage 

The  cordwood  must  be  store  into  dry  place,  away  from  bad 
weather. 

It should not be stored under or near the stove. 

If  any  wood  is  stored  next  to  the  stove,  it  must  respect  the 
minimum clearances to avoid self-ignition temperature. 

 

10 inches (25.4 cm) behind 

 

20 inches (50.8 cm) beside 

 

48 inches (122 cm) in front 

 

Draft 

Draft is the force which moves air from the appliance up through 
the chimney. The amount of draft in your chimney depends on 
its  length,  local  geography,  nearby  obstructions  and  other 
factors.  Too much  draft may cause  excessive  temperatures  in 
the appliance and may damage the appliance.  

An  uncontrollable  burn  or  excessive  temperature  indicates 
excessive draft. 

Insufficient draft will cause the appliance to leak smoke into the 
room through appliance and chimney connector joints.’ 

MAINTENANCE 

Ash Removal 

The wood burning 

doesn’t transform the wood into combustion 

gas completely. It  makes some residue called ash and it must 
be  removed  from  the  combustion  chamber  to  help  oxygen 
circulation.  

The  ash  have  to  be  removed  periodically  every  2  or  3  days 
during  heavy  warming  period.  Never  had  excessive 
accumulation  into  the  combustion  chamber  because  it  can 
reduce performances of your stove by diminish the air circulation 
between logs.  

When ashes get 3 to 4 inches deep in your firebox, and when 
the fire has burn down and cooled, remove excess ashes. Leave 
an ash bed approximately 1 inch deep on the firebox bottom to 
help maintain a hot charcoal bed. 

The best time to remove ash is after a long warming period like 
morning when the stove is relatively cold enough to manipulate 
ash  and  the  chimney  is  still  hot.  The  hot  chimney  draft  will 
vacuum the dust inside the stove. 

To clean ash from the combustion chamber, you must have the 
following tool. 

 

Ash shovel; 

 

Ash brush; 

 

A metal bucket with airtight lid. 

Some embers is mix with ash and still lit a few hours or a few 
days.  It  is  very  important  that  the  metal  lid  was  airtight.  The 
bucket must be put on a non-combustible tile or brick. 

 

Ash Disposal 

Some  embers  mixed  with  ash  can  still  be  lit.  If  embers  have 
enough oxygen, they can still stay lit some hours and even a few 
days. 

It’s mandatory to store ash pending disposal:  

 

Into a metal container with an airtight metal lid correctly 
closed  

 

Outside the house on a non-combustible material such 
as gravels, concrete and bricks. 

 

Far enough any combustible material. 

 

Far enough any inflammable liquid and vapor. 

 

If  the ash are  disposed  of by burial  in soil  or otherwise locally 
dispersed, they should be retained in the closed container until 
all cinders have thoroughly cooled.  

NEVER PUT TRASH INTO THE ASH CONTAINER. 

Содержание PIONEER

Страница 1: ...T RESTRICTION AND INSTALLATION INSPECTION IN YOUR AREA Instruction Manual PLEASE READ CAREFULLY AND KEEP THIS MANUAL FOR FUTURE REFERENCE 490 rue de l Argon Qu bec CANADA G2N 2C9 T l 418 849 8095 Fax...

Страница 2: ...nstallation 21 Transportable building installation 22 Chimney installation General steps 23 Inside Masonry Chimney Vertical Installation 24 Outside Vertical Installation 24 Cathedral Vertical Installa...

Страница 3: ...d on the floor Do not install in a sleeping room Exterior air inlet is mandatory for mobile home use All roof chimney termination shall be able to be readily removed at or below an elevation of 13 1 2...

Страница 4: ...PR_I017 2023 01 23 EN 4 RATING PLATE...

Страница 5: ...PR_I017 2023 01 23 EN 5 APPLIANCE DIMENSION...

Страница 6: ...PR_I017 2023 01 23 EN 6...

Страница 7: ...PR_I017 2023 01 23 EN 7...

Страница 8: ...cm Exterior Depth 33 5 8 in 85 6 cm 33 5 8 in 85 6 cm 34 1 4 in 87 cm 33 5 8 in 85 6 cm Door Opening 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in...

Страница 9: ...ior Depth 33 5 8 in 85 6 cm 34 3 8 in 87 3 cm 34 3 8 in 87 3 cm 36 1 4 in 91 9 cm Door Opening 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 c...

Страница 10: ...m 16 inches 40 6 cm Front 48 inches 121 9 cm 48 inches 121 9 cm 48 inches 121 9 cm 48 inches 121 9 cm Minimum Ceiling height 84 inches 213 4 cm 84 inches 213 4 cm 84 inches 213 4 cm 84 inches 213 4 cm...

Страница 11: ...fuels e g Charcoal and possibilities of generating carbon monoxide and the hazards from carbon monoxides When the smoke detector is activated is mean that the smoke spill out of the appliance Verify...

Страница 12: ...for a stove with side shield is 16 inches 40 6cm and for a stove without side shield the clearance is 23 inches 58 4 cm For a 45 corner or other corner installation the minimum clearance between the...

Страница 13: ...rated and secure it with nut lock washer and washer 2 3 4 Attention Be sure the legs are in place correctly positioned and in contact with the bottom of the stove Fan and Snap disc box installation Th...

Страница 14: ...ONT OF THE APPLIANCE When it s ON the snap disc will start at the moment when the temperature of ventilation box gets 120 Fahrenheit 49 Celsius DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DIS...

Страница 15: ...ke double pipe For the smoke simple pipe it s not necessary to remove the pre cut metal part For the double smoke pipe you need to remove the pre cut metal part See blue arrow below Put the smoke pipe...

Страница 16: ...firebrick installation Put 8 bricks A on the back wall and fix with a screw and brick support Floor firebricks installation Put 4 Bricks A near to the back wall and 2 bricks P in front of bricks A Fl...

Страница 17: ...eel parts on the rockwool as illustrated 1 Put 3 A bricks over the two top pipes and push them against the back bricks Be sure to eliminate any space between the back bricks and the bricks you install...

Страница 18: ...ration and parts without ash plug 1 2 half disk metal steel plates 2 1 rock wool insulating blanket 3 3 3 4 x 15 pipes with holes on a single side 4 2 3 4 x 15 pipes with bigger holes on both side 5 1...

Страница 19: ...d list of parts with ash plug 1 2 half disk metal steel plates 2 1 rock wool insulating blanket 3 3 3 4 x 15 pipes with holes on a single side 4 2 3 4 x 15 pipes with bigger holes on both side 5 1 scr...

Страница 20: ...nce by a certified installer Note This appliance have to be connected to 6 inches 15 24 cm factory build chimney HT UL 103 or CAN ULC S629 compliant or a 6 inches 15 24 cm masonry chimney with a homol...

Страница 21: ...earances and inclinations of the horizontal sections and verify if you have all the necessary parts for the final installation o For direct vertical installation you will need 1 vertical section of 24...

Страница 22: ...stance of 4 inches 10 2 cm or more in order to avoid contact with chimney f The chimney must exceed at least 3 feet 91 4 cm from the highest point of opening made in the roof and exceed also 2 feet fr...

Страница 23: ...installation method Always refer to the manufacturer s manual of the chimney for a more detailed method for your chimney 1 Determine the total length needed for your chimney 2 Cut the holes into all...

Страница 24: ...re of the manner you have to To install the stove onto an abandoned masonry fireplace and use the good condition masonry chimney the chimney must have inside a certified metallic sleeve cover up all t...

Страница 25: ...e with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Follow the chimney manufacturer s instructions to install the chimney Always pass chimney between joists If a joist need to be cu...

Страница 26: ...certified Installer Always frame around chimney Keep minimal clearances written into your chimney manual Do not fill the gap between the fire stop and the chimney Nothing must be in contact with the c...

Страница 27: ...ntake box Insert the pipe into the hole and screw the pipe using the 3 holes in the tabs Put a generous layer of high temperature latex caulking onto the joint to ensure the pipe is sealed 2 Cut the e...

Страница 28: ...re 2 type of tubes used into the stove Three of them are single side perforated 1 and are in the back of the heat chamber The 2 tubes in front of the heat chamber are double side perforated tube 2 How...

Страница 29: ...O Disc Low burn rate From the high burn rate coal bed when 5 to 6 lbs left the load can be inserted in the firebox Open the door Insert the 36 lbs 16 3 Kg load in the wood heater Close the door immedi...

Страница 30: ...rewood over the ember keeping it away from the glass door to avoid flame touching the ceramic glass ATTENTION DO NOT OVER CHARGE THE STOVE OVER THE UPPER BRICK DO NOT BUILD A FIRE NEAR THE WINDOW THIS...

Страница 31: ...ent draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints MAINTENANCE Ash Removal The wood burning doesn t transform the wood into combustion gas co...

Страница 32: ...ng chimney also requires to climb on the roof to remove the chimney cap and sometime even a very high chimney section too We recommend to call a Professional chimney Sweeper certified by APC in Quebec...

Страница 33: ...m braided fiberglass rope To install the new fiberglass rope we recommend to detach the door from the stove Please see the pertinent section in this manual Fiberglass rope preparation 1 Take the end o...

Страница 34: ...PR_I017 2023 01 23 EN 34 ANNEX 1 Exploded diagram of door Arc door...

Страница 35: ...PR_I017 2023 01 23 EN 35 ANNEX 2 Fans electric wiring diagram...

Страница 36: ...3 Parts that can be replaced Bricks Door glass Spring Handle Stove Door with handle Fans Flat fiber glass rope around glass Round fiberglass rope Ash Plug Slotted Brick Washer Call your stove seller...

Страница 37: ...t or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted p...

Отзывы: