• The fireplace must be disconnected from the gas supply system when components that measure
intake gas pressure are being installed. Once the gas supply is reconnected, check all connections as
well as the gas meter (or tank) connected to the fireplace for tightness. Make sure there are no leaks
(sees section 6.6).
6.5. PROCEDURE FOR CHECKING GAS PRESSURE FROM THE
FIREPLACE VALVE
• Make sure the manual valve is closed.
• Loosen the input “IN” and/or the output “OUT”
pressure verification port(s) by turning counter
clockwise with a 1/8 in. (3 mm) wide screwdriver
(figure 6.5).
• Connect the pressure gauge to the input “IN”
and/or output “OUT” pressure verification port(s)
using a rubber hose with a 5/16 in. (8 mm) inner
diameter.
• Open the manual valve (you will get the intake
pressure).
• Turn on the fireplace to check outlet pressure.
• When you are done reading the pressure gauge,
turn off the fireplace, close the manual valve, disconnect the hose and tighten the screw(s) (clockwise)
with a small flat screwdriver (1/8 in. wide).
• Make sure the output pressure of the automatic valve is comprised between the numbers listed in this
table.
WARNING
Never use an open flame to check for gas leaks.
Figure 6.5
CAUTION
A manual shut-off valve must be installed before
the
SmartCase
®
. It must be easy to access (see figure
6.2).
WARNING
Connection must be performed by a certified
installer.
Содержание loo RGR-25
Страница 18: ...18 2 3 FIREPLACE DIMENSIONS 2 3 1 LOO RGR 25 INSERT 2 3 2 MISTRAL RGP 25 PENINSULA...
Страница 19: ...19 2 3 3 AUSTER RGCG 25 LEFT CORNER 2 3 4 MOUSSON RGCD 25 RIGHT CORNER...
Страница 20: ...20 2 3 5 SIROCCO RGB 25 PANORAMIC 2 3 6 PAMPERO RGC 25 CENTRAL...
Страница 21: ...21 2 3 7 SUROIT RGV 25 SEE THRU...
Страница 25: ...25 3 1 2 3 LOO RGR 25 INSERT WITH TOP EXIT 3 1 2 4 LOO RGR 25 INSERT CORNER INSTALLATION WITH TOP EXIT...
Страница 26: ...26 3 1 2 5 MISTRAL RGP 25 PENINSULA WITH BACK EXIT 3 1 2 6 MISTRAL RGP 25 PENINSULA WITH TOP EXIT...
Страница 27: ...27 3 1 2 7 AUSTER RGCG 25 LEFT CORNER WITH BACK EXIT 3 1 2 8 AUSTER RGCG 25 LEFT CORNER WITH SIDE EXIT...
Страница 28: ...28 3 1 2 9 AUSTER RGCG 25 LEFT CORNER WITH TOP EXIT 3 1 2 10 MOUSSON RGCD 25 RIGHT CORNER WITH BACK EXIT...
Страница 29: ...29 3 1 2 11 MOUSSON RGCD 25 RIGHT CORNER WITH SIDE EXIT 3 1 2 12 MOUSSON RGCD 25 RIGHT CORNER WITH TOP EXIT...
Страница 30: ...30 3 1 2 13 SIROCCO RGB 25 PANORAMIC WITH BACK EXIT 3 1 2 14 SIROCCO RGB 25 PANORAMIC WITH TOP EXIT...
Страница 31: ...31 3 1 2 15 PAMPERO RGC 25 PAMPERO WITH TOP EXIT 3 1 2 16 SUROIT RGV 25 SEE THROUGH WITH SIDE EXIT...
Страница 61: ...61 7 4 ELECTRICAL DIAGRAM OF SMARTCASE...