8
March 1
st
, 2015
Minimums clearances to the non-combustible material.
With these reduced clearances, this appliance take a minimum of space where is installed. Whether in the living room or the dining
room, the Cook stove will complete your decorate by his originality and heating, it requires a minimum clearance of 12 inches to the
back (for a smoke simple pipe with a heat shield ) and a 18 inches lateral MINIMUM clearance.
•
In the case with a smoke simple pipe without heat shield, you must installed the cooker stove that the smoke pipe is
to 18 inches of all non-combustible material therefore the MINMUM clearance at the back of the stove will be 16¼
inches (41.3cm).
•
For a 45° corner installation, or other corner installation, the minimum clearance between the cook stove and non-
combustible material must be 18 inches (Figure 3).
Figure 3
Содержание FORGERON
Страница 4: ...4 March 1st 2015 Nameplate...
Страница 5: ...5 March 1st 2015 Appliance Dimensions Figure 1...
Страница 28: ...28 March 1st 2015 Annexe 1 Door assembly...