background image

 

 

 

 

 
 

 
 
 
 
 
 
 

J. A. ROBY LIMITED LIFE WARRANTY 

WOOD BURNING STOVES & FIREPLACES 

 
J. A. ROBY’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been 
altered, modified nor repaired since shipment from factory.  The products covered by this warranty must be manufactured after review date indicated 
at the bottom of page. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your 
J. A. ROBY dealer.  Registered your warranty is not required. 
 
The  appliance  must  be  installed  by  an  authorized  service  technician  or  contractor.  Installation  must  be  done  in  accordance  with  the  installation 
instructions included with the product and all local and national building and fire codes.  Any service call related to an improper installation is not 
covered  by  this  warranty.    This  warranty  applies  to normal  residential  use  only.  This  limited  warranty  does  not  cover  damages  caused  by  misuse, 
improper installation, lack of maintenance, accident during transportation, alterations, power failure, venting problems, downdrafts, abuse, over firing 
or neglect. Operating the appliance on high for extended periods of time is neglect. Any defect or damage caused by the use of unauthorized parts or 
others than original parts void this warranty.

 

 

This limited warranty does not cover any scratch, corrosion, warping or discoloration. The manufacturer may require that defective products be returned 
and/or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a 
product is found to be defective, the manufacturer will repair or replace such defect. The transportation fees to ship back the product to the purchaser 
will be paid by the manufacturer

2

. The external labour fees related to warranty repair are not covered.  The manufacturer may at its discretion, decide 

to repair or replace any part or unit after inspection and investigation of the defect. The manufacturer may at its discretion, fully discharge all obligations 
with  respect  to  this  warranty  by  refunding  to  the  original  warranted  purchaser  the  wholesale  price  of  any  warranted  but  defective  part  (s).    The 
manufacturer shall not in no event be liable for any special, indirect or consequential damages of any nature whatsoever which exceeds the original 
purchase price of the product. All parts replaced under this limited life warranty are subject to a single claim.

 

 

Any  damage  to  the  appliance,  combustion  chamber,  heat  exchanger,  enameled  cast  iron  cooking  plate  or  other  components due  to water,  weather 
damage, long periods of dampness, condensation, damaging chemical or cleaner will not be the responsibility of J. A. ROBY. Failure of any components 
which is attributed to poor maintenance, is not warrantable and will not be covered by this policy.  J.A. ROBY neither assumes, nor authorizes any 
third party to assume, on its behalf, any other liabilities with respect to the sale of this product.

 

 

The manufacture of your new appliance and the following materials are warranted against defects as mentioned below: 

 

 

WARRANTY DESCRIPTION 

100% 

50% current retail price 

Ashtray, handles, doors and cast iron legs 

Life 

 

Combustion chamber 

2 years 

After 2 years 

Secondary air tubes 

2 years 

After 2 years 

Tempered glass, optional blower and gasket 

1 year 

 

Ceramic glass (thermal breakage only

1

1 year 

 

Replacement parts (with proof of purchase) 

90 days 

 

Due to on-doing product improvements, all specifications and design are subject to change without prior notice

.

 

 

Before  shipping  your  unit  or  defective  component  to  our  plant,  you  must  obtain  from  J.  A.  ROBY  dealer  an  authorization  number.  Any 
merchandise shipped to our plant without authorization will be refused automatically and returned to sender. 

 

 

1

= Digital pictures required       

2

= Shipping cost are not covered outside CANADA

  

Review oct. 2014

 

STOVES & FIREPLACES 

Содержание Chief

Страница 1: ...95 Fax 418 849 0077 www jaroby com Certified and tested according to Canadian Safety ULC S627 00 United States Safety UL 1482 2011 Emission EPA Method 28R ASTM2510 Efficiency CSA B415 1 10 Elda Cuistot Chief Wood stove with cooking capability PLEASE READ CAREFULLY AND KEEP THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ... 17 STAINLESS STEEL TUBES REPLACEMENT 18 Stainless steel tubes Installation 18 How to install the tubes 18 OPERATING INSTRUCTIONS 19 Burning regime control 19 Lightning fire 19 First fire 19 Keeping a fire 20 Fuel Selection 20 Moisture Meter Information 20 Things not to burn 20 Wood storage 20 Draft 20 Usage of cooking area and oven 21 Cooking Area 21 Use of cooking holes 21 Lids above the firebox...

Страница 3: ...ration see pages 19 20 26 28 It is against U S federal regulations to operate this wood stove in an inconsistent manner with the operating instructions in this manual Mobile home approved This appliance is approved for mobile home installation The structural integrity of the mobile home floor ceiling and walls must be maintained and respect construction code When installed in mobile home the appli...

Страница 4: ...6 cm 12 ft 366 cm Exterior height 37 in 95 25 cm 58 in 148 6 cm 58 in 148 6 cm Exterior width 41 in 105 7 cm 41 in 105 7 cm 51 in 131 4 cm Exterior depth 26 in 66 7 cm 26 in 66 7 cm 26 in 66 7 cm Door opening 9 x 9 in 22 9 x 23 2 cm 9 x 9 in 22 9 x 23 2 cm 9 x 9 in 22 9 x 23 2 cm Interior height 11 in 29 5 cm 11 in 29 5 cm 11 in 29 5 cm Interior width 12 in 30 5 cm 12 in 30 5 cm 12 in 30 5 cm Inte...

Страница 5: ... The heat radiation from the stove which might cause an auto ignition to the floor or to the floor covering Possible flow of creosote when there is a fire chimney The coating used for the protection must be non combustible and approved according to UL1618 standard for the USA or to the local codes Example cement brick ceramic tiles etc HORIZONTAL VENTING MANDATORY PROTECTION Non combustible floor ...

Страница 6: ...r decor by his originality and warmth Here is the minimum clearance for different certified flue pipes Double wall flue pipe distance Single wall flue pipe with shield Single wall flue pipe To know how to reduce those dimensions you have to contact your local authority for installing an heat shield on a wall Installations with reduced clearances must comply with NFPA211 or CAN CSA B365 standards M...

Страница 7: ... warmer 1 as well as the decorative faceplate 2 1 Open the installation opening at the bottom right of the warmer by removing the screws 5 and the plate 4 2 Place and align the warmer with the corresponding holes on the top of the stove You will have two bolts on each extremity 3 and they can be accessed under the top by the lids Two other screws are located on each side of the flue collar 4 and c...

Страница 8: ...of the gas from wood which wouldn t be burnt in any other manner The rockwool above the brick prevents leakage between the bricks and keeps a maximum heat inside combustion chamber It must cover up all the bricks and the air corridors of both sides IMPORTANT The rockwool must not obstruct the smoke path Check the rockwool by removing the left top lid hole in the hob and make sure that it is in a g...

Страница 9: ...e two half round steel plates over the rockwool near the rear deflector already in place Be sure to put them under the rear deflector to maximise the clearance between the rockwool and the rear deflector Make sure the rockwool is not obstructing the space by looking under the cooking lid on the hub WARNING Obstructing the smoke path under the deflector can force smoke to exit by the door when it s...

Страница 10: ...have to be connected to 6 inches 15 24 cm factory build chimney HT UL 103 or CAN ULC S629 compliant or a 6 inches 15 24 cm masonry chimney with a homologated sleeve inside The masonry chimney liner must be made of stainless steel and meet the standards for masonry chimney with inner sleeve 4 Install the chimney following the manufacturer instruction 5 Put the stove directly on the floor aligned ve...

Страница 11: ...r indication s for approved double wall chimney pipe ALL PIPE SECTIONS MUST BE CLEAN AND IN GOOD CONDITION AND THEY MUST BE APPROVED FOR CORDWOOD FUEL How to set the pipe sections Make an installation overview of all sections and elbows if necessary to ensure that you meet the clearances and the horizontal sections inclination Check if you have all the necessary parts for the final installation Fo...

Страница 12: ...imney is exposed outside from a wall and placed lower than 7 feet 213 cm above the ground level where the mobile home is situated a guard must be installed around the chimney at the height of 7 feet 213 cm If openings are made in the guard they must be less than inch 19 5 mm wide guard openings must be kept at least 4 inches 10 2 cm away from the chimney surface in order to avoid contact f The chi...

Страница 13: ...ary for your chimney 2 Cut the holes in all the floors and in the roof 3 If you need to cut a joist be sure to strengthen the adjacent joists and frame the hole respecting the minimum dimensions between combustible materials and the firewall Follow the manufacturer s instructions in the manual provided with the firewall Never cut a structural beam 4 Frame the holes on each floor and attic respecti...

Страница 14: ...rity to find the latest information in terms of construction standards To install a stove with a chimney serving a masonry fireplace you must have a certified stainless steel sleeve inside covering up all the chimney height The sleeve must have the same diameter as the flue collar The connection must be tight and sealed to avoid fume to go indoor Don t forget to add an opening for sweeping Outside...

Страница 15: ... accordance with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Regarding the installation of chimney follow the chimney manufacturer s instructions Always pass chimney between joists If a joist need to be cut refer to the local building code to know how to do it safely Otherwise ask a carpenter or a certified Installer Always frame around chimney Keep minimal clearances as writte...

Страница 16: ...rtified Installer Always frame around chimney Keep minimal clearances as written in your chimney manual Do not fill the space between the frame and the chimney Nothing must be in contact with the chimney Always install a firewall at each level floor ceiling attic and roof A special firewall need to be install in the attic It allows to keep the insulation layers away from the chimney Always pass in...

Страница 17: ...ST BE FIXED TO THE STRUCTURE WHEN AN EXTERIOR AIR INTAKE IS INSTALLED Installation of Air Intake Pipe You can find external air intake head and grating in hardware store The back panel is removed in the following picture only to show the flue collar 1 Find the air intake under the appliance 2 Fix the flexible or rigid pipe to the air intake collar with a pipe clamp A To install the outdoor air int...

Страница 18: ...nstall The three tubes in the back 1 are perforated from a single side and the second tube in the front 2 is also perforated from a single side but with bigger holes than the other tubes The first tube in front 3 is perforated on both side with smaller holes as on the 1 2 3 tubes How to install the tubes 1 Insert the tube on either end into the round hole of the hot air channel 2 Insert the other ...

Страница 19: ...lowing the instructions of the manufacturer you are ready to light it up 1 Pull the handle under the front table of the stove forward to let the air admission enter in the combustion chamber 2 Put paper and kindling wood in the combustion chamber and light the fire in your preferred way 3 Close the door partially keeping a slight opening When the chimney is hot enough close completely the door and...

Страница 20: ...common method used for cordwood Season wood outdoor in summer for at least 6 months before use Properly seasoned wood is darker has cracks at the ends and sounds hollow when one piece is smacked against one another In most parts in the North America the minimum moisture content that can be generally obtained by air drying is about 12 to 15 percent Things not to burn 1 Garbage 2 Lawn clippings or y...

Страница 21: ...gulf in the opening and it will cool down the chimney and diminish the draft inside the stove Moreover smoke might come out from the openings if the draft in the chimney diminishes too much Lids above the firebox Above the firebox there are two lids nested in one another One is 7 inch diameter and the other is 10 inch diameter 1 Before removing the 10 inch lid it is strongly recommended to remove ...

Страница 22: ...y the chimney when it gets hot enough It is therefore important to respect the minimum chimney length according to the standard to get the optimal performance You can refer to the section of the chimney installation in this manual regarding the minimum chimney length Note Each stove installation is different and certain variables can nevertheless affect the chimney draft and improve impair the sto...

Страница 23: ... are 4 access points 1 The 2 round lids on the hob which allow the cleaning of the oven top 2 The little rectangular hatch located on the top right corner of the hob which allows access to the right side of the oven 3 A rectangular hatch is located directly under the oven door which allow access to the bottom part of the stove This door is also convenient to remove creosote deposits that might hav...

Страница 24: ...incompletely burned it produces tar and other organic vapors which condensate as creosote The creosote vapor condenses on the relatively cold flue walls As a result creosote residue accumulates on the flue lining The creosote could be in forms of tarry liquid dust soot or crystallized deposit This creosote makes an extremely hot fire when ignited and it is the principal cause of chimney fire The c...

Страница 25: ...with a spanner partially or completely so that you can liberate the upper part of the door 3 Remove the tilted door from the lower hinge by lifting it To reassemble the door 1 Put the door on the bottom hinge and align the top part of the door straight 2 Screw back the top hinge bolt assembly A B C inside the door hinge as shown and make sure the left side of the door is pressed evenly against the...

Страница 26: ...around the groove without giving any tension and measure the length of the rope 5 Add inch to the length measured in step 4 and repeat the step 2 3 for the new rope end Fiberglass rope installation 1 Put high temperature latex inside the clean groove in order to glue the fiberglass rope 2 Starting from the lower corner near the hinge put the fiberglass rope into the groove without giving any tensi...

Страница 27: ...July 13 2017 27 APPENDIX 1 Exploded diagram of doors Oven door Glass dimension Order Code CB VPF ...

Страница 28: ...July 13 2017 28 Square Stove door Glass Dimension Order Code CB VPC ...

Страница 29: ...July 13 2017 29 Arc Stove door Glass dimension Order Code CB VPA ...

Страница 30: ...July 13 2017 30 Reservoir Door Glass dimension Order Code CB VPR ...

Страница 31: ...maintenir la température de l eau sur une période prolongée Attention Pour remplir le réservoir d eau chaude J A Roby préconise l utilisation d une bouilloire conventionnelle en métal placée directement sur le dessus du poêle The J A Roby s decorative water tank adds a touch of aesthetic to your cook stove while completing your kitchen set As expected it also provides an handy source of warm water...

Страница 32: ...es 4 espaces du réchaud prévus à cet effet 3 Appuyer le réservoir a eau sur les 4 vis puis serrer les vis complètement X 4 INSTALLATION DU RÉSERVOIR 1 Screw partially the 4 screws A provided with the water tank Keep enough clearance in order to hang the water tank on them 2 Hang the water tank on the 4 screws by passing each one of them in the waters tank s spaces provided to that effect 3 Support...

Страница 33: ...lle et de l eau 4 Replacer le réservoir en le plaçant plutôt vers l arrière afin que la porte n heurte pas la tête du robinet en la refermant FILLING OF THE WATER TANK 1 Open the lid and remove the second stainless steel removable lid 2 Poor hot water directly inside the water tank and put back the lid to prevent water condensation in the water tank chamber Warning It is not recommended to consume...

Страница 34: ...ENDIX 3 Replaceable parts Bricks Door glass Spring Handle Stove Door with handle Flat fiber glass rope around glass Round fiberglass rope Ash Plug Slotted Brick Washer Call your stove seller representative to order parts ...

Страница 35: ...rranty repair are not covered The manufacturer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part s The manufacturer shall not in...

Отзывы: