Architecture 

13

 

 

4  Architecture 

4.1  PC Memory Allocation 

The CAN controllers are displayed directly in the memory space of the PC. They 
can be accessed via basic a Offset. 

 

0000h

0100h

0200h

0300h

03FFh

1.CAN-Controller

Reset CAN1

2.CAN-Controller

Reset CAN2

+ Basisadresse

 

Fig. 4-1:

 PC memory allocation of the PC-I 04/104 

4.1.1  Access to CAN Controllers 

Up to two CAN controllers either of type Philips SJA1000 can be assembled on 
the interface.  

The first CAN controller is displayed in the range from 0000h to 00FFh, the 
second CAN controller in the range from 0200h to 02FFh plus basic address of 
the board. With access to the individual memory range, the corresponding CAN 
controller is automatically selected. The basic address can be configured as 
described in section 3.1.1.  

The Output Control Register of the CAN controller must be loaded with the value 
DEh or 5Eh. 

The exact index description of the SJA1000 is given in the corresponding data 
sheets of Philips (see Appendix C).  
 

4.1.2  Resetting the CAN Controllers from the PC 

By writing a random value to an address of the Reset range (0100h to 01FFh 
for the first CAN controller and 0300h to 03FFh for the second CAN controller), 
a hardware reset is carried out on the corresponding CAN controller. 

 

4.2  Triggering an Interrupt on the PC 

The CAN controllers can trigger interrupts on the PC. For configuration of the 
interrupts, see section 3.1.2 

Offset 

Содержание PC-I 04/104

Страница 1: ...PC I 04 104 Passive PC CAN Interface HARDWARE MANUAL ENGLISH...

Страница 2: ...s document is only allowed with explicit permission of HMS Technology Center Ravensburg GmbH HMS Technology Center Ravensburg GmbH reserves the right to change technical data without prior announcemen...

Страница 3: ...3 1 3 Setting the Interrupt Mode 10 3 1 4 Providing Power Supply via CAN Connector 11 3 2 Design of the CAN Connectors 11 3 2 1 Connection of the bus interface 12 3 3 Bus Termination 12 4 Architectur...

Страница 4: ......

Страница 5: ...The following 11 interrupt lines are available 3 4 5 6 7 9 10 11 12 14 and 15 CAN bus interface according to ISO 11898 2 high speed on board galvanically isolated as an option Separate bus interface f...

Страница 6: ...must be carried out on an earthed anti static work mat Take the following steps in sequence 1 Find a free memory segment on the PC of at least 1 kByte in the range 1MB ISA memory range and a free int...

Страница 7: ...addresses marked with X cannot be influenced Beginning with the set basic address the PC CAN interface occupies an address space of 4 kByte In this address range the interface can be addressed as a no...

Страница 8: ...FF ON OFF ON ON CE000h ON ON OFF OFF OFF ON ON ON CF000h ON ON OFF OFF OFF OFF ON ON D0000h def ON OFF ON ON ON ON ON ON D1000h ON OFF ON ON ON OFF ON ON D2000h ON OFF ON ON OFF ON ON ON D3000h ON OFF...

Страница 9: ...0h OFF OFF ON ON ON OFF ON ON F2000h OFF OFF ON ON OFF ON ON ON F3000h OFF OFF ON ON OFF OFF ON ON F4000h OFF OFF ON OFF ON ON ON ON F5000h OFF OFF ON OFF ON OFF ON ON F6000h OFF OFF ON OFF OFF ON ON...

Страница 10: ...e listed in the following table The default setting is marked with def default setting Trigger type JP12 JP14 JP15 Sides ISA mode def 1 2 X 2 3 Level Shared Low EISA 1 2 X 1 2 Shared High 3 4 closed1...

Страница 11: ...JP2 8 VCC open JP8 JP3 Caution This voltage may be loaded with maximum 100 mA With galvanically isolated bus interfaces GND and VCC are also galvanically isolated from the power supply of the PC Fig...

Страница 12: ...AN_H 5 GND 6 n c 7 n c 8 VCC via JP3 9 n c 10 n c With galvanically isolated bus interfaces GND and VCC are also galvanically isolated from the power supply of the PC 3 3 Bus Termination Bus terminati...

Страница 13: ...ic address of the board With access to the individual memory range the corresponding CAN controller is automatically selected The basic address can be configured as described in section 3 1 1 The Outp...

Страница 14: ...height without PC 104 connector Weight approx 55 g Working temperature range 20 to 70 C Relative humidity 10 95 non condensing Power supply 5 V DC 5 Power consumption typically 80 mA max 150 mA CAN c...

Страница 15: ...ddress D000h A17 ON A16 OFF A15 ON A14 ON A13 ON A12 ON A11 ON A10 ON Interrupt CAN 1 IRQ 5 Interrupt CAN 2 IRQ 7 only if assembled Interrupt mode CAN line 1 JP12 1 2 JP15 2 3 ISA mode Interrupt mode...

Страница 16: ...he article numbers 1 01 0070 10100 1 01 0070 10200 1 01 0070 11110 1 01 0070 11220 do comply with the EC directives 2004 108 EC Applied harmonized standards in particular EN 55022 2006 A1 2007 EN 5502...

Отзывы: