Configuration 

10

 

 

3.1.2 Setting the PC Interrupt 

The required interrupt can be set separately for each CAN controller via the 
jumper boards JP 10 (for CAN 1) and JP 11 (for CAN2). To set an interrupt on 
the interface, the corresponding jumper must be closed. Only one interrupt may 
be selected for each CAN controller. If no interrupt is required, no jumper of the 
corresponding jumper board may be closed. The factory setting of the interface 
is IRQ 5 for the first CAN controller and (if present) IRQ 7 for the second CAN 
controller.  
 

3.1.3 Setting the Interrupt Mode 

The interface PC-I 04/104 provides three different types of interrupt triggering. 
These can be set for CAN1 via the jumpers JP12, JP14 and JP15 and (if 
present) for CAN2 via JP13, JP20 and JP21. The jumper settings are listed in 
the following table. The default setting is marked with def. = default setting. 
 

Trigger type 

JP12 

JP14 

JP15 

Sides 

ISA mode 

(def.)

 

1-2 

2-3 

Level 

Shared Low 

(EISA) 

1-2 

1-2 

Shared High 

3-4 

closed

1

 

2-3 

Table 3-3:

 Setting of the interrupt mode for CAN1 

 

Trigger type 

JP13 

JP20 

JP21 

Sides 

ISA mode 

(def)

 

1-2 

2-3 

Level 

Shared Low 

(EISA) 

1-2 

1-2 

Shared High 

3-4 

closed

2-3 

Table 3-4:

 Setting of the interrupt mode for CAN2 

 

 

                                         

1

 

Note on use of Shared High interrupt triggering: 

With interrupt triggering Shared High, an IRQ line is used by several interrupt sources (e.g. 

first CAN controller, second CAN controller, further ISA boards). The PC/104 specification 

stipulates that the interrupt line must have only one 1 k Ohm resistor between ground and IRQ 

line (see PC/104 specification Appendix C.3). A 1 k Ohm resistor can be connected via JP14 

(CAN1) or JP20 (CAN2). If this trigger type is used with a PC-I 04/104 interface equipped with 

two CAN controllers, this means that either jumper JP14 

or

 JP20 is to be closed.

 

Содержание PC-I 04/104

Страница 1: ...PC I 04 104 Passive PC CAN Interface HARDWARE MANUAL ENGLISH...

Страница 2: ...s document is only allowed with explicit permission of HMS Technology Center Ravensburg GmbH HMS Technology Center Ravensburg GmbH reserves the right to change technical data without prior announcemen...

Страница 3: ...3 1 3 Setting the Interrupt Mode 10 3 1 4 Providing Power Supply via CAN Connector 11 3 2 Design of the CAN Connectors 11 3 2 1 Connection of the bus interface 12 3 3 Bus Termination 12 4 Architectur...

Страница 4: ......

Страница 5: ...The following 11 interrupt lines are available 3 4 5 6 7 9 10 11 12 14 and 15 CAN bus interface according to ISO 11898 2 high speed on board galvanically isolated as an option Separate bus interface f...

Страница 6: ...must be carried out on an earthed anti static work mat Take the following steps in sequence 1 Find a free memory segment on the PC of at least 1 kByte in the range 1MB ISA memory range and a free int...

Страница 7: ...addresses marked with X cannot be influenced Beginning with the set basic address the PC CAN interface occupies an address space of 4 kByte In this address range the interface can be addressed as a no...

Страница 8: ...FF ON OFF ON ON CE000h ON ON OFF OFF OFF ON ON ON CF000h ON ON OFF OFF OFF OFF ON ON D0000h def ON OFF ON ON ON ON ON ON D1000h ON OFF ON ON ON OFF ON ON D2000h ON OFF ON ON OFF ON ON ON D3000h ON OFF...

Страница 9: ...0h OFF OFF ON ON ON OFF ON ON F2000h OFF OFF ON ON OFF ON ON ON F3000h OFF OFF ON ON OFF OFF ON ON F4000h OFF OFF ON OFF ON ON ON ON F5000h OFF OFF ON OFF ON OFF ON ON F6000h OFF OFF ON OFF OFF ON ON...

Страница 10: ...e listed in the following table The default setting is marked with def default setting Trigger type JP12 JP14 JP15 Sides ISA mode def 1 2 X 2 3 Level Shared Low EISA 1 2 X 1 2 Shared High 3 4 closed1...

Страница 11: ...JP2 8 VCC open JP8 JP3 Caution This voltage may be loaded with maximum 100 mA With galvanically isolated bus interfaces GND and VCC are also galvanically isolated from the power supply of the PC Fig...

Страница 12: ...AN_H 5 GND 6 n c 7 n c 8 VCC via JP3 9 n c 10 n c With galvanically isolated bus interfaces GND and VCC are also galvanically isolated from the power supply of the PC 3 3 Bus Termination Bus terminati...

Страница 13: ...ic address of the board With access to the individual memory range the corresponding CAN controller is automatically selected The basic address can be configured as described in section 3 1 1 The Outp...

Страница 14: ...height without PC 104 connector Weight approx 55 g Working temperature range 20 to 70 C Relative humidity 10 95 non condensing Power supply 5 V DC 5 Power consumption typically 80 mA max 150 mA CAN c...

Страница 15: ...ddress D000h A17 ON A16 OFF A15 ON A14 ON A13 ON A12 ON A11 ON A10 ON Interrupt CAN 1 IRQ 5 Interrupt CAN 2 IRQ 7 only if assembled Interrupt mode CAN line 1 JP12 1 2 JP15 2 3 ISA mode Interrupt mode...

Страница 16: ...he article numbers 1 01 0070 10100 1 01 0070 10200 1 01 0070 11110 1 01 0070 11220 do comply with the EC directives 2004 108 EC Applied harmonized standards in particular EN 55022 2006 A1 2007 EN 5502...

Отзывы: