![iXsystems TrueNAS X Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/ixsystems/truenas-x-series/truenas-x-series_basic-setup-manual_2098882013.webp)
Support: 1-855-473-7449 or 1-408-943-4100
Page 11
10 Logging in to the TrueNAS Web Interface
The IP address of the TrueNAS graphical web interface is on the TrueNAS hardware sales order or configuration
sheet. The system console also displays it after powering on (see section 11.1.1). Please contact iX Support if the
TrueNAS web interface IP address was not provided with these documents or cannot be identified from the True
-
NAS system console.
Enter the IP address into a browser on a computer on the same network to access the web interface. To log into the
TrueNAS web interface, enter the default credentials:
Username:
root
Password:
abcd1234
Your system is equipped with the optimal BIOS and IPMI firmware out of the box.
DO NOT UPGRADE your system’s BIOS and IPMI firmware.
11 Out-of-Band Management
Out-of-Band Management (OOBM) allows you to connect directly to the TrueNAS hardware and make changes us-
ing the system console. You should immediately test to confirm the OOBM Ethernet port IP address is active.
Remote support requires functioning addresses.
If iXsystems preconfigured the system, they have set the OOBM
interfaces to the requested IP addresses. Otherwise, the OOBM IP addresses default to these static addresses:
• TrueNAS Controller 1:
192.168.100.100
, subnet mask
255.255.255.0
• TrueNAS Controller 2 (if present):
192.168.100.101
, subnet mask
255.255.255.0
Viewing or resetting these IP addresses to different values requires directly connecting to the X-Series system using
a USB-3.5mm cable and client system with a serial terminal program.
Temporarily connect the included black USB serial cable to the 3.5mm port on the back of the TrueNAS controller.
Be sure to disconnect this cable when done!
Connect the serial ca
ble’s USB end to a computer running serial terminal software. The device name can vary by
operating system. Here are some typical examples:
• Windows:
COM{4}
• macOS:
/dev/tty.usbserial{xynnn}
• FreeBSD:
/dev/cuaU{0}
• Linux:
/dev/ttyUSB{0}
Set the terminal software to:
38400 baud, 8 data bits, 1 stop bit, no parity, no flow control
After connecting, you might need to wait for the X-Series to power up, then press
Enter
to display the console
menu. When prompted, use these credentials to log in to the interface:
Username / Password:
sysadmin
/
superuser