5 ES60 Cable Management Arm
The included cable management arm (CMA) is not required for operation. If desired, the CMA can be used to help
organize the ES60 power and data cables.
The tabs along the side of the flex housing can be unclipped from the top, the bottom, or removed entirely.
5.1 Install the Cable Management Arm
There are two attachment posts on the left rear side of the ES60 for the CMA. Pulling the units lightly out of the rack
can make these posts more accessible. Align the holes on the CMA chassis bracket with the posts. Slide the cable
management arm forwards and pull the lever on the latch upwards to lock the bracket into place.
Locate the end of the flex housing with exposed pins. Un-clip and open the two tabs closest to the end, allowing the
flex housing to compress enough to fit into the bracket holes. Press the flex housing firmly into the bracket until the
pins seat in the holes.
Note:
You can only use the Cable Management Arm if your rackmount rail depth is between 27.5” and 31”.