background image

12

2010-06/MU/OCT 3kG4 /001 / Ed. B

13

2010-06/MU/OCT 3kG4 /001 / Ed. B

WEB-based User Interface - Menus and Options Overview

Find hereafter all the menus and options of the WEB-based User Interface and their uses

Menu /options

Used to …

Define the OCTANS 3000 orientation, pos-

sible  roll,  pitch  and  heading  misalign-

ments, primary and secondary lever arms 

useful to compute the heave and position 

for the output protocols that provide it

Define  the  inputs,  the  protocol  used  to 

input the data, the serial (parity, baud rate, 

standard (RS232 or RS422) and stop bit)or 

Ethernet (transport layer, IP address, Port 

number) parameters

Define  the  outputs,  the  protocol  used  to 

output the data, the lever Arm to use, the 

data rate or the input pulse to use to syn-

chronize the output data, the serial (parity, 

baud rate, standard (RS232 or RS422) and 

stop bit)or Ethernet (transport layer, IP ad-

dress, Port number) parameters, the pulse 

output to output the envelop, the heave fil-

ter to use

Menu /options

Used to …

Define  the  Network  parameters  for  com-

munication through a serial ling (PPP op-

tion) or through Ethernet one (DHCP client 

mode activation, OCTANS 3000 IP address 

and Network mask to use

Enter  the  initial  latitude  and  speed  or  to 

update them

Define the parameters of 

• The  time  synchronization  (UTC);  input 

selection, pulse input selection for the PPS 

signal, the protocol to use for the PPS si-

gnal 

• The  log:  pulse  input  selection  for  the 

speed synchronization signal, the protocol 

to  use  for  the  synchronization  signal,  the 

scale factor for the chosen protocol
To be informed in case of warning or error 

for

• PPS synchronization loss

• Time synchronization loss

• External latitude synchronization loss 

• External speed synchronization loss

Содержание Octans 3000

Страница 1: ...Quick G Quick Start Guide Octans 3000 subsea gyrocompass and motion sensor...

Страница 2: ...the OCTANS 3000 and the basic configurations required before beginning the positioning Contents OBJECTIVE 01 CONTENTS 01 CONVENTIONS 02 OCTANS 3000 SYSTEM OVERVIEW 03 VERIFICATION OF PACK CONTENTS 03...

Страница 3: ...me computation The heading search algorithm has been designed by IXSEA Heading and attitudes are computed whether the system is in movement or not and without an external reference point Computation i...

Страница 4: ...ccurs at each OCTANS 3000 powering on or soft restart It is performed in parallel with the OCTANS 3000 alignment phase but it is time set to 5 addi tional minutes During the heave initialization phase...

Страница 5: ...e Environment 1 6 and higher The Control Pages opens During the first seconds the IXSEA logo is flashing grey blue indicating that the Web based User Interface is loading the internal configuration of...

Страница 6: ...o changes and the detailed status pop up automatically appears showing immediately which equipment has raised the problem Table 1 Color code definition General Rules for Using Command Windows The comm...

Страница 7: ...the hidden area by clicking on its text label title OK Cancel buttons Each command page contains the same buttons they appear as soon as a modification or a selection has been made in the command page...

Страница 8: ...tput data the serial parity baud rate standard RS232 or RS422 and stop bit or Ethernet transport layer IP ad dress Port number parameters the pulse output to output the envelop the heave fil ter to us...

Страница 9: ...apidly If the latitude information input is incorrect OCTANS 3000 will produce an error Important OCTANS 3000 is delivered with a default latitude setting that corresponds to IXSEA s factory location...

Страница 10: ...NIT UPDATE option of SETUP menu to open the INIT UPDATE page Enter the correct value in the Latitude field Click OK button to save the modification into OCTANS 3000 PROM Step 4 Click on maintenance me...

Страница 11: ...direct connection to the 24V power supply with banana pins Connection to PC Use the 19 pin test cable for direct connection to the workstation Input output Ports Use the 19 pin test cable The pin ass...

Страница 12: ...southern hemisphere 4 Click on OK button 5 End of procedure Configuring the Inputs Outputs Up to five inputs outputs are available A B C D and E For each input output you can define the following par...

Страница 13: ...input port is not connected 3 Configure the relevant parameters of the selected port by choosing them in the various drop down lists of the Protocol Physical Link Serial or Ethernet areas 4 Click on O...

Страница 14: ...f necessary choose the Heave filter to apply for more detail see Part 2 of your OCTANS 3000 manual 7 Click on OK button 8 End of procedure OCTANS 3000 is now ready for positioning STEP 3 more The prev...

Страница 15: ...refer to Part 2 of the OCTANS 3000 User Guide Pulse Input Output Three pulse Inputs and one pulse output are available on OCTANS 3000 For more details about The pulse connector pins refer to Part 2 o...

Страница 16: ...a com You can also contact IXSEA headquarters in France or one of its representatives around the Contact Phone Fax IXSEA SAS France 33 0 1 30 08 98 88 33 0 1 30 08 88 01 IXSEA BV The Netherlands 31 0...

Страница 17: ...30 2010 06 MU OCT 3kG4 001 Ed B 31 2010 06 MU OCT 3kG4 001 Ed B PERSONAL NOTES PERSONAL NOTES...

Страница 18: ...32 2010 06 MU OCT 3kG4 001 Ed B PERSONAL NOTES...

Отзывы: