IXOM GridBee GF1250PWc Скачать руководство пользователя страница 3

Carefully read safety information when you see 

any safety symbols.

Be sure you have read all installation, operation, maintenance and safety instructions before 

you install, service or begin to operate this unit.

Accidents occur every year because of careless use of industrial equipment.  You can avoid hazards 

by following these safety instructions, and applying some ordinary common sense when operating or 

servicing this unit.

Keep in mind that

 

full operator attention and alertness

 

are required when operating or servicing 

this unit.

USE COMMON SENSE!!

  

Most accidents can be avoided by using

 

common sense and 

concentration

 

on the job being done.

©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | [email protected]

Safety

1949_10036_20210428

O&M_GF1250PWc_10110_20210922 - 1

Содержание GridBee GF1250PWc

Страница 1: ...2021 IXOM Watercare Inc www ixomwatercare com 866 437 8076 watercare ixom com O M_GF1250PWc_10110_20210922 GridBee GF1250PWc Owner s Manual...

Страница 2: ...le of Contents 10014_20210413 GridBee GF1250PWc Owner s Manual Safety 1 Operation 4 Features 8 Maintenance 14 Electrical 21 Troubleshooting 23 Parts Diagram 26 Dimension Drawing 27 Appendix 28 Technic...

Страница 3: ...can avoid hazards by following these safety instructions and applying some ordinary common sense when operating or servicing this unit Keep in mind that full operator attention and alertness are requi...

Страница 4: ...tive ELECTRICAL HAZARD WARNING THIS EQUIPMENT CONTAINS HIGH VOLTAGE ELECTRICAL SHOCK CAN CAUSE SERIOUS OR FATAL INJURY ONLY QUALIFIED PERSONNEL SHOULD ATTEMPT PLACEMENT OPERATION AND MAINTENANCE OF EL...

Страница 5: ...all relative OSHA and local regulations while installing and performing any maintenance to the mixer circulation equipment Key OSHA Compliance Standards that must be followed and not limited to are 19...

Страница 6: ...entle mixing de stratification and surface renewal The GF series GridBee requires a minimal amount of AC grid power The grid provides power to the onboard AC DC power box and motor controller that dri...

Страница 7: ...base of the machine can be performed on the reservoir exterior prior to lowering the equipment inside if the hatch has a clear opening of at least 24 inch diameter 60cm A hatch this size or larger wil...

Страница 8: ...ne by pushing hose up and all the way up above metal rib See Figure 6 STEP 3 On the other end of the hose place the other hose clamp over the end Fasten hose to the intake box past the metal rib of th...

Страница 9: ...LLY ASSEMBLED 2021 IXOM Watercare Inc www ixomwatercare com 866 437 8076 watercare ixom com Small Frame Assembly SB GF1250PWc SB GF1250PWc Assembly Assembly Diagram 10312_20210810 O M_GF1250PWc_10110_...

Страница 10: ...on the inside of the tank Motor Controller The motor controller is located near the motor just below the top plate of the Gridbee The motor controller is sealed in line with the electrical cord that r...

Страница 11: ...nto the housing of the brushless motor fastening it onto the machine The brushless motor is built to be very durable The housing is constructed of casted aluminum The brushless motor runs very quietly...

Страница 12: ...ree to rotate on the shaft If the water should freeze around the machine the freeze sleeve will stand still frozen in by the ice but inside the plastic sleeve the impeller shaft will be turning The im...

Страница 13: ...ieve best flow results The distributor dish depth is set at the factory and should not need adjustment after deployment Hose Intake The hose extends from below the dish down to the floor of the reserv...

Страница 14: ...is shaped to hug the hose for installation purposes allowing the machine to be installed in a 24 square hatch The floats have a uniquely designed shape to Minimize space when collapsed around the hos...

Страница 15: ...nit frame when the float is extended into place by means of boyancy pressure when deployed into the water If the machine is resting in the bottom of an empty tank the GridBee will be supported against...

Страница 16: ...irst every time the Machine is inspected or having maintenance procedures performed It is strongly encouraged that anyone working on or near the machine follow these rules Wear a personal floatation d...

Страница 17: ...ee points to be used in order to support the weight of the machine and keep it balanced once suspended 500PWc CAUTION DO NOT REMOVE ANY FLOAT ASSEMBLY PINS OR BOLTS WHILE THE MACHINE IS FLOATING IN TH...

Страница 18: ...entry Therefore the float assembly were designed to set the machine in the correct depth of water when the machine is deployed There are no adjustments that needed for setting the dish depth After the...

Страница 19: ...te and at least 20 seconds This step is easier with two people one counting revolutions and the other keeping track of the time expired STEP 3 Quit counting revolutions and immediately observe how muc...

Страница 20: ...al laws and regulations when disposing of any materials collected STEP 5 Once clean place impeller assembly back in place Be sure bottom of impeller shaft fits into the bushing in the dish and that th...

Страница 21: ...nd STEP 2 Cover the entire machine including the hose and intake assembly using a heavy duty tarp Be sure to tuck the tarp under the machine to avoid any sand being collected on the machine in the cas...

Страница 22: ...not get tangled on any objects STEP 7 The machine is now ready for the tank to be filled with water and be turned On Most customers feel that removing the machine circulation equipment is the best opt...

Страница 23: ...NNECTION GRID POWER ONLY 120VAC 60HZ 2 0 AMPS MOTOR CONTROLLER BRUSHLESS DC MOTOR 2021 IXOM Watercare Inc www ixomwatercare com 866 437 8076 watercare ixom com Electrical Electrical Overview GF Series...

Страница 24: ...e red light blinking once followed by one yellow blink and one green If you miss this or are unsure you can repeat the previous steps If the update was not successful the red yellow and green lights w...

Страница 25: ...BEFORE ENTERING ENCLOSURE IXOM WATERCARE INC STRONGLY RECOMMENDS THAT AN ELECTRICIAN INSTALL A BREAKER SWITCH OR OTHER TYPE OF SWITCH THAT WOULD DISCONNECT AC POWER GOING INTO THE ELECTRONIC CONTROL B...

Страница 26: ...otor circuit voltage can be measured off terminal blocks 1 and 2 The proper motor voltage should be approximately 45vDC Brain Board voltage should be approximately 12vDC and can be measure as shown to...

Страница 27: ...PPLY LED SOLID GREEN LIT SOLID GREEN NOT LIT ERROR CODES 12 VDC ON 12 VDC OFF 12 VDC POWER SUPPLY LED SOLID GREEN LIT SOLID GREEN NOT LIT Source Power Circuit 120 VAC Control Circuit 12 VDC Motor Powe...

Страница 28: ...14013022 Motor Control Cord 04 PN 20504700 Brushless Motor 05 PN 100161 Control Box with Brainboard 06 PN 26060840 8 x 40 Hose NSF White 07 PN 18010015 Distributor Dish 08 PN 26283008 Intake Box Assem...

Страница 29: ...21 IXOM Watercare Inc www ixomwatercare com 866 437 8076 watercare ixom com Dimension Drawing 1250PWc Dimension Drawing SB GF Series Small Frame Mixers 789_10242_20210730 O M_GF1250PWc_10110_20210922...

Страница 30: ...Technical Data Sheets 2021 IXOM Watercare Inc www ixomwatercare com 866 437 8076 watercare ixom com Appendices Appendix Additional Component Information 10576_20210611 O M_GF1250PWc_10110_20210922 28...

Страница 31: ...Intake Hose 20 to 60 feet 6 to 18 m available in 8 inch 20 cm diameter X 20 feet 6 m sections Intake Assembly at Bottom of Hose Rectangular intake with openings around perimeter Intake Depth Adjustme...

Страница 32: ...e function 3 two bytes of register address two bytes of number of points and the CRC The address of the holding registers can be found in the table below The format of the reply consists of the GridBe...

Страница 33: ...able 7 NA Not Applicable 8 NA Not Applicable 9 Visual Status Indicator This value gives an indication of the GridBee controller health blink indicator During normal operation the following values will...

Страница 34: ...GPS Comm Motor Comm and Analog OOR Error For Customer Service contact Ixom Watercare Inc Office and Service Center at 866 437 8076 Table 4 Visual Status Indicator Register Address 9 Priority Levels Pr...

Страница 35: ...y S N PART A 36 2 4 V 20014700 1234XXXX 7 Motor Specifications Size 7 inch 18cm diameter X 4 inch 10cm height Weight 25 lb 12 kg Housing Sealed 356 T6 Cast Aluminum Shaft Stainless Steel V ring seal T...

Страница 36: ...e factory s service crews performed the original on site placement and startup then this warranty also includes labor Where labor is included in lieu of sending a factory service crew to the site for...

Страница 37: ...the world Contact us today to discuss your water quality and service needs EVERYONE DESERVES GREAT CUSTOMER SUPPORT IXOM Watercare earns customer trust with unparalleled service start to finish Every...